1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
2. Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error. NOTE: It may be necessary to configure slot to Gen1 or to use special
utility software so that adapter firmware can be upgraded. Gen1/Gen2 settings can be
configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3
Speed Selection, or the ASU Utility.
3. Move adapter to a different system slot, if available.
4. Replace adapter.
•
I.3048005 UEFI has booted from the backup flash bank. Booting Backup UEFI Image
Explanation:
UEFI has booted from the backup flash bank. Booting Backup UEFI Image
Severity
Info
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
2. Reflash Primary UEFI image. Refer to UEFI Recovery section of service information for this
product.
3. Replace the standard I/O book.
Related links
– “Updating the firmware ” on page 119
– “Replacing the standard I/O book” on page 227
•
I.3808004 The IMM System Event log (SEL) is full. IPMI System Event Log is Full
Explanation:
The IMM System Event log (SEL) is full. IPMI System Event Log is Full
Severity
Info
User Response
Complete the following steps:
1. Use IMM Web Interface to clear event log.
2. If IMM communication is unavailable, use F1 Setup to access System Event Logs Menu and
Choose Clear IMM System Event Log and Restart Server.
•
I.3818001 The firmware image capsule signature for the currently booted flash bank is invalid.
Current Bank CRTM Capsule Update Signature Invalid
Explanation:
The firmware image capsule signature for the currently booted flash bank is invalid. Current
Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Reboot system. Will come up on backup UEFI image. Reflash the primary UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, replace the standard I/O book.
•
I.3818002 The firmware image capsule signature for the non-booted flash bank is invalid. Opposite
Bank CRTM Capsule Update Signature Invalid
Appendix D. UEFI/POST error codes
1931
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......