background image

This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged 
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of 
the Info Center for the appropriate user response. 

Related links

–  Finding the UEFI (POST) error code

• 

806f050c-2b840001 : Memory Logging Limit Reached for [PhysicalMemoryElementName] on 

Subsystem [MemoryElementName]. 

IMM has reported that the Memory Logging Limit has been Reached on DIMM 1 in Compute Book 4.

May also be shown as 806f050c2b840001 or 0x806f050c2b840001

Severity

Warning

Serviceable

Yes

Automatically notify support

Yes

Alert Category

Warning - Memory

SNMP Trap ID

43

CIM Information

Prefix: 

PLAT 

ID: 

0144

User Response

This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged 
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of 
the Info Center for the appropriate user response. 

Related links

–  Finding the UEFI (POST) error code

• 

806f050c-2b840002 : Memory Logging Limit Reached for [PhysicalMemoryElementName] on 

Subsystem [MemoryElementName]. 

IMM has reported that the Memory Logging Limit has been Reached on DIMM 2 in Compute Book 4.

May also be shown as 806f050c2b840002 or 0x806f050c2b840002

Severity

Warning

Serviceable

Yes

Automatically notify support

Yes

Alert Category

Warning - Memory

SNMP Trap ID

43

CIM Information

Prefix: 

PLAT 

ID: 

0144

User Response

1086

System x3850 X6 and x3950 X6 Installation and Service Guide

Summary of Contents for 6241

Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...

Page 2: ...nmental Notices and User s Guide and the Warranty document that comes with the server Thirteenth Edition May 2019 Copyright Lenovo 2014 2019 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 ...

Page 3: ...talling an adapter in the standard or half length I O book 90 Installing an adapter in the full length I O book 91 Installing specific optional adapters 93 Installing a RAID cache card 97 Installing a RAID adapter flash power module in the storage book 97 Installing a RAID adapter flash power module in the standard I O book 98 Installing power supplies 100 Installing a 750 watt 48 volt to 60 volt ...

Page 4: ...tem x3850 X6 and x3950 X6 Type 6241 201 Replaceable server components 201 Consumable parts 218 Power cords 219 Chapter 6 Removing and replacing components 221 Returning a device or component 221 Removing and replacing server components 221 Removing and replacing consumable parts 221 Removing and replacing Tier 1 CRUs 222 Removing and replacing Tier 2 CRUs 273 Removing and replacing FRUs 284 Append...

Page 5: ...e 1952 Software service and support 1953 Hardware service and support 1953 Taiwan product service 1953 Appendix F Notices 1955 Trademarks 1956 Important notes 1956 Recycling information 1956 Particulate contamination 1957 Telecommunication regulatory statement 1957 Electronic emission notices 1958 Federal Communications Commission FCC statement 1958 Industry Canada Class A emission compliance stat...

Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 7: ...rt eerst de veiligheidsvoorschriften Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Les sikkerhetsinformasjonen Safety Information før du installerer dette produktet...

Page 8: ...er is used to cross reference an English language caution or danger statement with translated versions of the caution or danger statement in the Safety Information document For example if a caution statement is labeled Statement 1 translations for that caution statement are in the Safety Information document under Statement 1 Be sure to read all caution and danger statements in this documentation ...

Page 9: ...disconnect cables as described in the following table when installing moving or opening covers on this product or attached devices To Connect To Disconnect 1 Turn everything OFF 2 First attach all cables to devices 3 Attach signal cables to connectors 4 Attach power cords to outlet 5 Turn device ON 1 Turn everything OFF 2 First remove power cords from outlet 3 Remove signal cables from connectors ...

Page 10: ...s or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Class 3A or Class 3B laser diode Note the following Laser radiation when open Do not stare into the beam do not view directly with optical instruments and avoid direct exposure to the beam Statement 4 CAUTION Use safe practices ...

Page 11: ...all a strain relief bracket option over the end of the power cord that is connected to the device you must connect the other end of the power cord to an easily accessible power source Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached...

Page 12: ...rrent supplied to the device The device also might have more than one connection to dc power To remove all electrical current from the device ensure that all connections to dc power are disconnected at the dc power input terminals Statement 26 CAUTION Do not place any object on top of rack mounted devices x System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 13: ...isconnect cables as described in the following table when you install move or open covers on this product or attached devices To Connect To Disconnect 1 Turn OFF all power sources and equipment that is to be attached to this product 2 Attach signal cables to the product 3 Attach power cords to the product For ac systems use appliance inlets For dc systems ensure correct polarity of 48 V dc connect...

Page 14: ...equired torque values for the wiring terminal screws 240VA Statement 35 CAUTION Hazardous energy present Voltages with hazardous energy might cause heating when shorted with metal which might result in splattered metal burns or both The 8U version of the server is intended for use in a system rack always installed on the load side of a Power Distribution Unit PDU or Uninterruptible Power Supply UP...

Page 15: ...xx v2 v3 v4 and E7 8xxx v2 v3 v4 processor technology This high performance scalable server is ideally suited for enterprise environments that require superior input output I O flexibility and high manageability Note You must purchase the x3950 X6 4 socket to 8 socket Upgrade kit to upgrade to an 8 socket server In addition the upgrade must be performed by a Lenovo approved warranty service provid...

Page 16: ...from the World Wide Web The server might have features that are not described in the documentation that comes with the server and the documentation might be updated occasionally to include information about those features or technical updates might be available to provide additional information that is not included in the server documentation To check for firmware updates go to http datacentersupp...

Page 17: ...nd model number Customer label space Customer label space Machine type and model number Customer label space Customer label space QR Codes In addition the system Service Card that is located between the left EIA bracket and the X6 Storage Book in the front of the server provides a quick reference QR code for mobile access to service information You can scan the QR code with a mobile device using a...

Page 18: ...ating system For a list of supported optional devices for the server go to http www lenovo com serverproven Go to http systemx lenovofiles com help topic com lenovo sysx 6241 doc printable_doc html for the Rack Installation Instructions document which contains complete rack installation and removal instructions Related documentation Use this information to identify and locate server related docume...

Page 19: ...ocument are also in the multilingual Safety Information document Each statement is numbered for reference to the corresponding statement in your language in the Safety Information document The following notices and statements are used in this document Note These notices provide important tips guidance or advice Important These notices provide information or advice that might help you avoid inconve...

Page 20: ...ermine the type and speed of the microprocessors in the server Memory depending on the model DIMM connectors 96 for the 4 socket and 192 for the 8 socket 24 DIMM connectors per compute book DDR3 compute book Type PC3 12800R 1600 MHz PC3L 12800 1600 MHz or PC3L 10600 1333 MHz Load Reduced LR single rank double rank or quad rank ECC 240 pin DDR3 registered SDRAM DIMMs only Supports standard 4 GB 8 G...

Page 21: ...red PCIe Gen3 x8 4 1 Note The optional also supports full length full height and low profile PCIe adapters Power supply The server supports up to four of the following power supplies 1400 watt ac input power supplies 900 watt ac input power supplies 750 watt 48 volt to 60 volt dc input power supplies In addition consider the following information A base model 4 socket node comes standard with one ...

Page 22: ... ServeRAID M5120 SAS SATA Controller for System x ServeRAID M5210 SAS SATA Controller for System x 8 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 23: ...75 Hz UXGA with support for 1680 x 1050 WSXGA wide screen resolution DDR3 528 MHz SDRAM video memory controller Avocent Digital Video Compression Video memory is not expandable Size Height 4 socket 172 8 mm 6 8 inches Height 8 socket 350 6 mm 13 8 inches Depth 4 socket and 8 socket 811 2 mm 31 9 inches Width 4 socket and 8 socket 447 mm 17 5 inches Maximum weight 4 socket 54 7 kg 120 3 lbs when fu...

Page 24: ...nt 5 to 100 Particulate contamination Attention Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server For information about the limits for particulates and gases see Particulate contamination on page 1957 Airflow Ideal airflow 35 cubic feet per minute CFM Typical airflow 50 CFM Maximu...

Page 25: ...rity cryptography mode set in the management device the Integrated Management Module II determines the security mode in which the server operates For more information on how to set or change the security cryptography mode see the Integrated Management Module II User s Guide at https systemx lenovofiles com help topic com lenovo sysx imm2 doc printable_doc html Product Type Rack server Year first m...

Page 26: ...ngers for different server models and evaluating how servers accommodate new workloads based on the availability of resources Reducing the power consumption to a minimum level to prolong service time during an emergency power event such as a data center power failure For more information about how to download install and use Lenovo XClarity Energy Manager see http www3 lenovo com us en data center...

Page 27: ...e IMM lights LEDs to help you diagnose the problem records the error in the IMM event log and alerts you to the problem The IMM also provides a virtual presence capability for remote server management capabilities The IMM provides remote server management through the following industry standard interfaces Intelligent Platform Management Interface IPMI version 2 0 Simple Network Management Protocol...

Page 28: ...tility select System Settings Memory Memory Mode Mirroring For information about installing DIMMs for memory mirroring see Memory mirroring on page 52 and Installing a memory module on page 46 for more information Memory sparing The server supports memory sparing Memory sparing reserves memory capacity for failover in the event of a DIMM failure and the reserved capacity is subtracted from the tot...

Page 29: ...ence and blue screen capture features are integrated functions of the integrated management module IMM The remote presence feature provides the following functions Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz regardless of the system state Remotely accessing the server using the keyboard and mouse from a remote client Mapping the USB flash drive on a remote client an...

Page 30: ...he UEFI firmware offers several features including Unified Extensible Firmware Interface UEFI version 2 1 compliance Active Energy Management AEM technology enhanced reliability availability and serviceability RAS capabilities and basic input output system BIOS compatibility support UEFI replaces the BIOS and defines a standard interface between the operating system platform firmware and external ...

Page 31: ... following RAS features 3 year parts and 3 year labor limited warranty 24 hour support center Automatic error retry and recovery Automatic restart on nonmaskable interrupt NMI Automatic restart after a power failure Backup basic input output system switching under the control of the integrated management module IMM Built in monitoring for fan power temperature voltage and power supply redundancy C...

Page 32: ...and redundant hot swap fans Redundant network interface card NIC support Remind button to temporarily turn off the system error LED Remote system problem determination support ROM based diagnostics and upgrade of flash ROM based code and diagnostics ROM checksums Serial Presence Detection SPD on memory VPD on system board power supply and hard disk drive or solid state drive backplanes microproces...

Page 33: ... have its own set of power supplies For additional information see FlexNode support on page 19 and Configuring a multinode system on page 131 FlexNode support This topic provides information about using FlexNode support to reconfiguring a multinode 8 socket configuration into two stand alone 4 socket configurations The Lenovo System x3850 X6 and x3950 X6 server provides support for reconfiguring a...

Page 34: ...tent configuration Configuration settings such as local storage I O adapters boot settings firmware ports and IMM and UEFI settings are saved as a server pattern that can be applied to one or more managed servers When the server patterns are updated the changes are automatically deployed to the applied servers Firmware compliance and updates Firmware management is simplified by assigning firmware ...

Page 35: ...arity Administrator REST APIs and can automate functions Integration with other management software Lenovo XClarity Administrator is available stand alone or as a bundled offering that is known asLenovo XClarity Pro Lenovo XClarity Pro is composed of the base Administrator product plus two Lenovo XClarity Integrator modules that provide integration into Microsoft Systems Center or VMware vCenter T...

Page 36: ...are interchangeable between the 4 socket and the 8 socket server except the chassis midplane shuttle and some microprocessors The following illustration shows the major components in the front of the server Midplane assembly Shuttle Chassis Front I O panel Storage book Compute book filler panel Compute book Front fan pack Storage book board assembly RAID adapter card 2 5 inch hard disk drive 2 5 i...

Page 37: ... it in the server open or close a latch and so on Orange on a component or an orange label on or near a component indicates that the component can be hot swapped which means that if the server and operating system support hot swap capability you can remove or install the component while the server is running Orange can also indicate touch points on hot swap components See the instructions for remo...

Page 38: ... USB 3 0 Video connectors and the PCIe slots for the storage host bus adapters Notes Power to the storage book and the storage backplanes is provided by the standard I O book The PCIe slots on storage book are dedicated storage host bus adapters slots Do not install any other adapters in these slots Other adapters are not supported in these slots You must power off the server and disconnect all po...

Page 39: ...or SATA hard disk drives and solid state drives When one of these LEDs is lit it indicates that the drive has failed When this LED is flashing slowly one flash per second it indicates that the drive is being rebuilt When the LED is flashing rapidly three flashes per second it indicates that the controller is identifying the drive Drive activity LEDs These green LEDs are on all hot swap drives When...

Page 40: ...f This button is also used as the physical presence for the Trusted Platform Module TPM You can use management software such as Lenovo XClarity Administrator software or the IMM2 interface to light this LED remotely This LED is controlled by the IMM2 Check log LED When this LED is lit yellow it indicates that there are errors that require further diagnosis Check the IMM event log for additional in...

Page 41: ...display panel Use this information for an overview of the LCD system information display panel which displays various types of information about the server The LCD system information display panel is attached to the Storage book on the front of the server The LCD system information display panel enables you to have quick access to system status firmware network and health information The following...

Page 42: ...FI bank Network icon This shows a system supporting four Ethernet ports If the numbers are flashing the ports are active UEFI POST code System status Lenovo x3850 X6 When you navigate through the hierarchy of the menu options on the LCD system information display panel the display panel shows the information for that option and the up and down arrows appear on the side of the display panel When yo...

Page 43: ...6 address System environmental information Ambient temperature CPU temperature AC input voltage Estimated power consumption Compute book Use this information for an overview of the compute book The compute book is in the front of the server Each compute book must have a minimum of one microprocessor one DIMM and one fan pack installed It provides the following connectors and slots One microprocess...

Page 44: ...rs on the microprocessor side of the compute book board DIMM 1 DIMM 2 DIMM 3 DIMM 4 DIMM 5 DIMM 6 DIMM 10 DIMM 11 DIMM 12 DIMM 7 DIMM 8 DIMM 9 Microprocessor The following illustration shows the location of the DIMM connectors on the non microprocessor side of the compute book board 30 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 45: ...ly 1 Power supply 2 Power supply 3 Power supply 4 Fan pack 9 Fan pack 10 I O book 1 I O book 2 Standard I O book Standard I O book Use this information to for an overview of the system standard I O book The components in the server standard I O book are the minimum set of I O components to form a server The standard I O book is not a hot swap module Therefore you must power the server off and disc...

Page 46: ...n on the 100BASE TX 1000BASE TX or 10GBASE TX interface for the Ethernet port Ethernet adapter slots Insert the dual port or quad port Ethernet adapters into these slots I O board error LED When this LED is lit it indicates that an error has occurred on the standard I O book board Locate LED Use this LED to visually locate the server among other servers You can use management software such as Leno...

Page 47: ...his connector The video connectors on the front and rear of the server can be used simultaneously Note The maximum video resolution is 1600 x 1200 at 75 Hz The following is an illustration of the standard I O book board The server standard I O book board provides the following slots connectors and integrated features Integrated Management Module v 2 IMM2 Real Time Management Module RTMM One ML ada...

Page 48: ...e half length I O book provides three PCIe Gen3 slots for half length adapters The I O book provides the following slots Three PCIe Gen3 slots Two x8 slots One x16 slot The following illustration shows the PCIe slots on the half length I O book board x8 PCIe Gen3 slots x16 PCIe Gen3 slot Half length I O book board Board power button The following illustration shows the connectors LEDs and controls...

Page 49: ...th I O book might cause an unrecoverable system error Attention If the I O bay is not populated with a full length I O book when the operation system boots or the operating system is still running a full length I O book cannot be hot added to the I O bay due to insufficient resources If the I O bay has a full length I O book installed when the operating system boots you can hot swap the full lengt...

Page 50: ...sent You cannot remove the I O book from the server until the power LEDs on all three adapter slots are off Blinking The slot is in the process of powering on or off Do not remove the I O book from the server Power button Press this button to power the full length I O book PCIe slots off or on The power LED for each slot blinks until all of the power LEDs for the slots are on or off not blinking F...

Page 51: ... server The server supports ac power supply configurations at both 220 V ac and 110 V ac The power supply bays are divided into two power domains Power supply bays 1 and 3 are in power domain A and power supply bays 2 and 4 are in power domain B You must use a power supply spacer when installing the 750 watt 48 volt dc power supplies and the 900 watt power supplies The power supply modules have th...

Page 52: ...r name Jumper setting J35 IMM security jumper Pins 1 and 2 Removes the security check allowing unsigned IMM firmware Pins 2 and 3 default Allows only signed IMM firmware to be flashed Note If no jumper is present the server responds as if the pins are set to the default The following table describes the functions of the SW1 switch block on the standard I O book board 38 System x3850 X6 and x3950 X...

Page 53: ...rnal cables Review the information in Safety on page v Installation guidelines on page 44 Handling static sensitive devices on page 46 and Turning off the server on page 40 2 Any standard I O book board switch or jumper blocks that are not shown in the illustrations in this document are reserved The following table describes the functions of the button on the standard I O book board Table 4 Button...

Page 54: ...the server can respond to requests to the service processor the integrated management module such as a remote request to turn on the server While the server remains connected to input power one or more fans might continue to run To remove all power from the server you must disconnect it from the power source Some operating systems require an orderly shutdown before you turn off the server See your...

Page 55: ...ptional x3950 X6 4 socket to 8 socket upgrade kits includes only the base hardware required to upgrade your 4 socket x3850 X6 system to an 8 socket x3950 X6 system All other options must be ordered in addition to the upgrade option power supplies compute books storage devices storage controllers memory etc For more system parts information see Replaceable server components on page 201 Note The upg...

Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 57: ...mware on page 119 For a list of supported optional devices for the server see http www lenovo com serverproven Attention Installing the wrong firmware or device driver update might cause the server to malfunction Before you install a firmware or device driver update read any readme and change history files that are provided with the downloaded update These files contain important information about...

Page 58: ... ibm com de support ecurep send_http html Standard upload with the system serial number http www ecurep ibm com app upload_hw Secure upload http www ibm com de support ecurep send_http html Secure upload with the system serial number https www ecurep ibm com app upload_hw Installation guidelines Use this information to understand the guidelines that you need to follow when you install the server a...

Page 59: ...l Serial Bus USB devices However you must turn off the server before you perform any steps that involve removing or installing adapter cables Blue on a component indicates touch points where you can grip the component to remove it from or install it in the server open or close a latch and so on Orange on a component or an orange label on or near a component indicates that the component can be hot ...

Page 60: ...es indoor humidity and increases static electricity Installing a memory module This information describes the type of DIMMs that the server supports and other information that you must consider when you install DIMMs in the server The following notes describe the types of dual inline memory modules DIMMs that the server supports and other information that you must consider when you install DIMMs s...

Page 61: ... Supported DDR3 DIMMs Capacity Density Ranks Organization Form factor Voltage Type Bandwidth MHz 4 GB 2 Gb 1R 512Mb x4 Low profile 1 35V RDIMM 1600 MHz 8 GB 4 Gb 1R 1024Mb x4 Low profile 1 35V RDIMM 1600 MHz 16 GB 4 Gb 2R 1024Mb x4 Low profile 1 35V RDIMM 1600 MHz 32 GB 4 Gb 4R 1024Mb x4 Low profile 1 35V LR DIMM 1600 MHz 64 GB 4 Gb 8R 1024Mb x4 Low profile 1 35V LR DIMM 1333 MHz The server suppor...

Page 62: ...any other type of DIMM in the same system as the 128 GB RDIMM is not supported The system must be running UEFI vcersion 4 10 build ID A9E140J or higher 48 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 63: ...pending on the memory configuration settings in the Setup utility it can also operate at 1 5 volt Each compute book has four memory channels eight DDR3 or DDR4 channels two DDR3 or DDR4 channels per memory channel and each DDR3 or DDR4 channel supports three DIMMs as shown in the following illustration When you replace a DIMM the server provides automatic DIMM enablement capability without requiri...

Page 64: ...ode on page 58 and Memory rank sparing in lockstep mode on page 59 eXFlash DIMMs This topic provides information about eXFlash DIMM installation and requirements The Lenovo System x3850 X6 and x3950 X6 server provides support for eXFlash DIMMs You can use eXFlash DIMMs in unused DIMM slots for solid state drive storage on the server For more information and notes about installing DIMMs see Install...

Page 65: ...DIMM 8 GB 4 Gb 1R 1024Mb x4 DDR3 Low profile 1 35V RDIMM 1600 MHz When you install eXFlash DIMMs follow the same installation order for the Independent memory mode with mirroring disabled as shown in the following table Table 9 DIMM population sequence for independent memory mode DIMM installation order Independent mode with memory mirroring disabled Independent mode with memory mirroring enabled ...

Page 66: ...emory channel 2 mirrors memory channel 3 This mirroring provides redundancy in memory but reduces the total memory capacity in half DIMMs must be installed in pairs for each compute book when using the memory mirroring feature The DIMM population must be identical size organization etc for memory channel 0 and memory channel 1 and identical for memory channel 2 and memory channel 3 Memory mirrorin...

Page 67: ...independent memory mode consider the following For more information and notes about installing DIMMs see Installing a memory module on page 46 For more information about DIMM population sequence see Memory mirroring in independent memory mode on page 54 and Memory rank sparing in independent mode on page 55 Independent memory mode provides the most efficient performance You can populate DIMMs in a...

Page 68: ...ling a memory module on page 46 and Independent memory mode on page 53 Consider the following information when using the memory mirroring feature in independent memory mode Independent memory mode provides the most efficient performance You can populate DIMMs in any order and there are no matching requirements However the DIMM population sequence in the following table will provide the best perfor...

Page 69: ...rank sparing reserves memory capacity for failover in the event of a DIMM failure and the reserved capacity is subtracted from the total available memory Memory sparing provides less redundancy than memory mirroring does If a predetermined threshold of correctable errors is reached the contents of the failing DIMM are copied to the spare memory and the failing DIMM or rank is disabled The DIMM ins...

Page 70: ...GB and 8 GB are used a minimum of two rank DIMMs must be installed per memory channel to support memory sparing When multi rank DIMMs that is 16 GB 32 GB and 64 GB are used one multi rank DIMM can be installed per memory channel to support memory sparing The total memory available in the system is reduced by the amount of memory allocated for the spare ranks 56 System x3850 X6 and x3950 X6 Install...

Page 71: ...Memory mirroring in lockstep mode on page 58 and Memory rank sparing in lockstep mode on page 59 For more information and notes about installing DIMMs see Installing a memory module on page 46 The following table lists the DIMM installation sequence for lockstep memory mode Table 12 DIMM population sequence for lockstep memory mode DIMM installation order Lockstep mode with memory mirroring disabl...

Page 72: ...ze organization etc for memory channel 0 and memory channel 1 and identical for memory channel 2 and memory channel 3 Memory mirroring reduces the maximum available memory by half of the installed memory For example if the server has 64 GB of installed memory only 32 GB of addressable memory is available when memory mirroring is enabled The following table lists the DIMM installation sequence for ...

Page 73: ...single rank DIMMs that is 4 GB and 8 GB are used a minimum of two rank DIMMs must be installed per memory channel to support memory sparing When multi rank DIMMs that is 16 GB 32 GB and 64 GB are used one multi rank DIMM can be installed per memory channel to support memory sparing The total memory available in the system is reduced by the amount of memory allocated for the spare ranks DIMM instal...

Page 74: ...g off the server on page 40 and all attached peripheral devices Disconnect all power cords then disconnect all external cables from the server 3 Remove the compute book from the server see Removing a compute book on page 291 4 Remove the compute book cover left or right cover depending on the DIMM connector in which you are installing the DIMM Press down on both blue touch points on the cover and ...

Page 75: ...s Microprocessor heatsink Compute book 5 Open the retaining clip on each end of the DIMM connector Note To avoid breaking the retaining clips or damaging the DIMM connectors open and close the clips gently Chapter 2 Installing optional devices 61 ...

Page 76: ...y press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously The retaining clips snap into the locked position when the DIMM is firmly seated in the connector Note If there is a gap between the DIMM and the retaining clips the DIMM has not been correctly inserted open the retaining clips remove the DIMM and then reinsert it 10 Replace the compute b...

Page 77: ... x8xx v2 series microprocessor installed before you install the new compute book you must update the firmware to a minimum firmware level to support the E7 x8xx v3 or v4 microprocessor The server will not operate without the firmware update The recommended minimum UEFI code level for E7 x8xx v2 and v3 is A9e130E The recommended minimum UEFI code level for E7 x8xx v4 is A9e132W The recommended mini...

Page 78: ...ver supports compute book configurations of two or four These are the only configurations supported The following tables list the installation sequence for the supported compute book configurations Table 14 Installation sequence for the two compute books configuration for a 4 socket server Compute book bay 1 bay 2 bay 3 bay 3 1 compute book 1 2 compute book 2 Table 15 Installation sequence for the...

Page 79: ...3 Bottom node bay 4 1 compute book 1 2 compute book 2 3 compute book 3 4 compute book 4 5 compute book 5 6 compute book 6 7 compute book 7 8 compute book 8 For more information about the compute book see Compute book on page 29 For more information about installing DIMMs see Installing a memory module on page 46 For a list of supported devices see http www lenovo com serverproven To install the co...

Page 80: ...this information for an overview of the type drives that the server supports The following notes describe the type of drives that the server supports and other information that you must consider when you install a drive For a list of supported drives see http www lenovo com serverproven The server can support up to eight 2 5 inch HDD or SSD drives sixteen 1 8 inch SSD drives or a combination of bo...

Page 81: ...ve bay numbers are the same Notes 1 When you mix drive backplane configurations IMM renumbers the drive bay IDs automatically 2 When mixing drive backplane configurations you must install all 1 8 inch solid state drive backplanes above all 2 5 inch hard disk drive or 2 5 inch solid state drive backplanes 3 If you install a 8x1 8 inch drive backplane assembly the drive IDs that are indicated on the...

Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 83: ... NVMe PCIe Gen3 solid state drive backplane rear view This drive backplane can support up to four 2 5 inch NVMe PCIe solid state drives The backplane signal cable is attached to the NVMe PCIe Gen3 solid state drive extender adapter Each NVMe PCIe Gen3 solid state drive extender adapter supports two NVMe PCIe solid state drives Port 0 Port 1 Port 2 Port 3 Power connector 4x2 5 inch SAS Gen3 12 Gb d...

Page 84: ...ector Port 1 SAS signal cable connector You can install a combination of 2 5 inch and 1 8 inch SAS SATA drive backplanes in the server for the maximum drive capacity However any SAS SATA adapter that you install in the server to control the backplane must be capable of supporting two internal 4 lane SAS SATA signal connectors Also the server must have a minimum of two compute books with microproce...

Page 85: ...stall an additional SAS SATA backplane in the lower backplane bay The drive IDs assigned by IMM2 match the IDs that are indicated on the server front bezel The operating system and uEFI report the hard disk drives attached to the 4x2 5 inch NVMe PCIe Gen3 solid state drive backplane as PCI devices 7 2 5 inch NVMe PCIe SSD drive PCIe slot 19 Empty 6 2 5 inch NVMe PCIe SSD drive PCIe slot 18 5 2 5 i...

Page 86: ...3 2 5 inch HDD SSD drive Empty 2 2 5 inch HDD SSD drive 1 2 5 inch HDD SSD drive 0 2 5 inch HDD SSD drive 72 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 87: ...The following illustrations show the supported backplane configurations to support eight drives This configuration consists of two 4x2 5 inch drive backplanes and requires two SAS signal cables This configuration consists of one 8x1 8 inch drive backplane and requires two SAS signal cables Chapter 2 Installing optional devices 73 ...

Page 88: ...SSD drive 6 1 8 inch SSD drive 5 1 8 inch SSD drive 4 1 8 inch SSD drive 3 1 8 inch SSD drive 2 1 8 inch SSD drive 1 1 8 inch SSD drive 0 1 8 inch SSD drive 74 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 89: ...guration consists of one 4x2 5 inch drive backplane and one 8x1 8 inch drive backplane and requires three SAS signal cables 3 2 5 inch HDD SSD drive 2 2 5 inch HDD SSD drive 1 2 5 inch HDD SSD drive 0 2 5 inch HDD SSD drive 4 1 8 inch SSD drive 5 1 8 inch SSD drive 6 1 8 inch SSD drive 7 1 8 inch SSD drive 8 1 8 inch SSD drive 9 1 8 inch SSD drive 10 1 8 inch SSD drive 11 1 8 inch SSD drive Chapte...

Page 90: ...instructions for installing 2 5 inch and 1 8 inch hot swap drives To install a hot swap SAS or SATA drive complete the following steps For information about installing drives see Installing drives on page 66 Note If you install only one drive you must install it in drive bay 0 Step 1 Before you begin read Safety on page v and Installation guidelines on page 44 Step 2 Remove the storage book see Re...

Page 91: ...ip to step 6 Step 5 To install a 1 8 inch drive complete the following step a Remove the filler panel EMC filler panel b Grasp the black and orange release latch on the drive tray handle of the drive tray in which you want to install the drive and slide the release latch to the right to unlock the drive tray handle then rotate the drive tray handle to the right Chapter 2 Installing optional device...

Page 92: ... operation through a ServeRAID adapter you might have to reconfigure your disk arrays after you install drives See the ServeRAID adapter documentation for additional information about RAID operation and complete instructions for using the ServeRAID adapter Step 7 If you are installing additional hot swap drives do so now Step 8 Complete the additional steps in Instructions for Business Partners on...

Page 93: ...t adapters on page 88 Supported RAID adapters on page 86 Supported RAID cache cards on page 87 and Supported host bus adapters on page 85 The half length I O book is hot swappable if no adapters are installed in the I O book However if adapters are installed in the I O book you must first press the Power button on the I O book and power off all three PCIe slots before you remove the I O book from ...

Page 94: ...ot in the server and slide it into the server Release latch Handle Handle Filler panel Step 6 Rotate the handle all the way up and push it into the server until the handle locks in place If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 117 Installing the full length I O book This information provides notes and other information that you n...

Page 95: ...supports both half length full height and full length full height and low profile PCIe Gen3 and Gen2 adapters When this I O book is installed in the server it is connected to compute book 3 or compute book 4 See Table 20 PCIe slot number and the associated compute books on page 81 You can install up to two full length I O books in the server You can also install one full length I O book and one ha...

Page 96: ...ntinued PCIe slot number facing the rear of the server Compute book associated with the PCIe slot 1 Compute book 4 2 Compute book 4 3 Compute book 4 4 Compute book 3 5 Compute book 3 6 Compute book 3 82 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 97: ...mes with the I O book Insert the bracket into the slots in the I O bay as shown in the illustration Release latch Extension bracket Filler panel Handle Step 7 Open the I O book cam handle Step 8 Align the I O book with the I O bay in the server and slide it into the server Step 9 Rotate the handle all the way up and push it into the server until it locks in place If you have other devices to insta...

Page 98: ...and K6000 adapter options in systems containing 1TB of system memory or more If these options are installed in systems with 1TB of memory or more it might cause undetected data corruption and system instability These options are only supported in systems containing less than 1TB of memory This limitation applies to both the 4 socket 4U and the 8 socket 8U configurations For information about the s...

Page 99: ...apters that the server supports For more information about installing adapters see Installing an adapter on page 83 Table 21 Supported host bus adapters and information about the adapters Name of adapter Notes N2215 SAS SATA Host Bus Adapter for System x This solid state drive controller provides no RAID support It helps provide optimized performance for applications that do not need RAID support ...

Page 100: ...adapter you also get RAID level 6 and 60 support You can also install the following RAID cache cards on this adapter for RAID levels 5 and 50 support ServeRAID M5100 Series 512 MB Cache RAID 5 Upgrade for System x ServeRAID M5100 Series 512 MB Flash RAID 5 Upgrade for System x ServeRAID M5100 Series 1 GB Flash RAID 5 Upgrade for System x Note When any one of these three cache cards is installed on...

Page 101: ... for System x RAID cache card You can install this cache card in the optional SAS adapter connector on the following ServeRAID controller ServeRAID M5120 SAS SATA Controller for System x Provides RAID levels 5 and 50 upgrade support This cache card comes with a flash power module Supercap pack that you can attach to this card It powers the integrated RAID subsystem long enough to store the cache c...

Page 102: ...s Intel X540 ML2 quad port 1 Gb T Ethernet Adapter for System x This adapter can only be installed in slot 10 on the standard I O book board Port 1 on the adapter is the default port for IMM Shared mode when enabled through UEFI This adapter provides the following features Single chip quad port 1 Gb Base T controller with integrated MAC and PHY PCI Express v2 1 with 5 0 GT s and 2 5 GT s support f...

Page 103: ...on the standard I O book board Port 1 on the adapter is the default port for IMM Shared mode when enabled through UEFI This adapter provides the following features PCIe Gen2 x8 dual port 10 Gb Base T controller in 50 mm wide ML2 form factor TCP IP Offload TOE Wake on LAN WOL UCM and CIM capable Supports standard pNIC or vNIC2 modes Unified networking delivering LAN and iSCSI over 10 Gb Base T Two ...

Page 104: ... cards must be installed in the RAID cache card connector on the RAID controller to enable this capability ServeRAID M5100 Series SSD Caching Enabler for System x FoD Cachecade 1 or 2 Enables a hard disk drive RAID array to have its own solid state drive cache The solid state drive cache is much larger than the DRAM cache on the controller and can provide better performance acceleration Cachecade ...

Page 105: ...he keys align correctly with the connector on the board Step 9 Insert the adapter into the connector aligning the edge connector on the adapter with the connector on the I O book board Press the edge of the connector on the adapter firmly into the connector Make sure that the adapter snaps into the connector on the I O book board securely Attention Make sure that the adapter is correctly seated in...

Page 106: ...pter into the connector on the board aligning the edge connector on the adapter with the connector on the I O book board Step 9 Press the edge of the connector on the adapter firmly into the connector on the board Make sure that the adapter snaps into connector securely Attention When you install an adapter make sure that the adapter is correctly seated in the connector on the board before you tur...

Page 107: ...n see the ServeRAID documentation at http datacentersupport lenovo com Attention Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code Notes This adapter is for external RAID and can be used when external storage expansion units...

Page 108: ...onnector Make sure that the adapter snaps into the connector on the I O book board securely Attention Make sure that the adapter is correctly seated into the connector before you turn on the server An incorrectly seated adapter might cause damage to the I O book board or the adapter Step 10 Close the PCIe retention lever Step 11 Follow the instructions for reinstalling the I O book that you remove...

Page 109: ...want to install the adapter Step 5 Touch the static protective package that contains the adapter to any unpainted surface on the outside of the server then grasp the adapter by the top edge or upper corners of the adapter and remove it from the package Step 6 Align the adapter so that the keys align correctly with the connector on the I O book board Step 7 Insert the adapter into the connector ali...

Page 110: ...page v and Installation guidelines on page 44 Step 2 Turn off the server see Turning off the server on page 40 and all attached peripheral devices Disconnect all power cords then disconnect all external cables from the server Step 3 Remove the storage book from the server see Removing the storage book on page 273 Step 4 Open the PCIe retention lever and remove the expansion slot cover from the slo...

Page 111: ...e card by the edges and remove it from the package Step 5 Align the cache card with the RAID cache card slot on the adapter and lower it onto the connector Step 6 Gently press down on the center of the cache card until it clicks into place on the connector and is firmly seated If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 117 Installin...

Page 112: ...ions on how to install a RAID adapter flash power module in the standard I O book Note You can install up to three RAID flash power modules in the standard I O book When you install RAID adapters that come with flash power modules in the standard I O book install the flash power modules in the slots inside the standard I O book air baffle to prevent them from overheating To install a RAID adapter ...

Page 113: ...ules in the two slots on the left side facing the front of the standard I O book of the air baffle route the cables through the clips and the holes on the side of the air baffle as shown in the following illustration When you install a flash power module in the slot on the right side of the air baffle route the cable through the hole under the flash power module slot Chapter 2 Installing optional ...

Page 114: ...te The information and instructions in this documentation apply to both the 4 socket and the 8 socket server The following list describes the types of power supplies that the server supports and other information that you must consider when you install power supplies The server default power supply configuration setting when shipped from the factory is non redundant mode with throttling enabled fo...

Page 115: ... installed in bays 1 and 4 4 power supplies Power supplies 1 2 3 and 4 must be the same input type that is all ac power supplies or all dc power supplies Four 750 watt 48 volt dc power supplies is the only 750 watt 48 volt dc power supply configuration that the server supports for each 4 socket node The following table lists the supported ac power supply configurations at both 220 V ac and 110 V a...

Page 116: ...u are installing see http www lenovo com serverproven Attention Only trained service technicians other than Lenovo approved service technicians are authorized to install and remove the 750 watt 48 V to 60 V dc power supply and make connections to or disconnections from the 750 watt 48 V to 60 V dc power source Lenovo service technicians are not certified or authorized to install or remove the 750 ...

Page 117: ...nents If you suspect a problem with one of these parts contact a service technician Statement 19 CAUTION The power control button on the device does not turn off the electrical current supplied to the device The device also might have more than one connection to dc power To remove all electrical current from the device ensure that all connections to dc power are disconnected at the dc power input ...

Page 118: ...und should use a two hole lug for safety 4 Attach signal cables to other devices 5 Connect power cords to their sources 6 Turn ON all the power sources Do not connect or disconnect any cables or perform installation maintenance or reconfiguration of this product during an electrical storm Connect all power cords to a properly wired and grounded power source Connect to properly wired power sources ...

Page 119: ...uthorized to install and remove the 750 watt 48 V to 60 V dc power supply and make connections to or disconnections from the 750 watt 48 V to 60 V dc power source Lenovo approved service technicians are not certified or authorized to install or remove the 750 watt 48 V to 60 V dc power cable You are responsible for ensuring that only a trained service technician install or remove the 750 watt 48 V...

Page 120: ... in until it snaps into place on the tabs on the side of the power supply bay Filler panel Spacer 750 watt ac power supply Power supply release tab Spacer release tab Step 8 Grasp the handle on the rear of the power supply and slide the power supply into the bay next to the spacer until it clicks into place and is seated firmly into the connector Step 9 Connect the other ends of the dc power cable...

Page 121: ...er supply that you are installing see http www lenovo com serverproven For more notes and information that you must consider when you install power supplies in the server see Installing power supplies on page 100 The following table lists the population sequence for the supported power supply configurations These configurations apply for each 4 socket node of the 8 socket server Table 29 Populatio...

Page 122: ...gurations at both 220 V ac and 110 V ac for each 4 socket node Number of power supplies Power supply wattage One 900 watt One 1400 watt Two 900 watt Two 1400 watt Four Two 900 watt and two 1400 watt Four 900 watt Four 1400 watt Statement 5 CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device...

Page 123: ...c protective surface Step 3 If you are installing the power supply into an empty bay remove the power supply filler panel from the power supply bay Step 4 Use one of the following procedures to install the power supply a To install a 1400 watt power supply complete the following steps 1 Grasp the handle on the rear of the power supply and slide the power supply forward into the power supply bay un...

Page 124: ... Restart the server Confirm that it starts correctly and recognizes the newly installed device and make sure that no error LEDs are lit Installing a USB embedded hypervisor flash device Use this information for instructions on how to install a USB hypervisor flash device To install a hypervisor flash device complete the following steps Step 1 Before you begin read Safety on page v and Installation...

Page 125: ... Notes The SAS SATA adapter that you install in the server to control the backplane must be capable of supporting two internal 4 lane SAS SATA signal connectors The server must have a minimum of two compute books with microprocessors and memory installed to support the controller backplane and drives When you install a 8x1 8 inch drive backplane assembly the drive IDs that are indicated on the ser...

Page 126: ...h you are installing the assembly 8x1 8 inch drive filler 8x1 8 inch drive backplane assembly Storage book Drive LEDs Step 7 Slide the drive backplane assembly into the backplane bay until it clicks into place Step 8 Connect the power cable to the power connector on the drive backplane assembly one end of the power cable is connected to the rear of the storage book Note If the cables are not conne...

Page 127: ...ll power cords then disconnect all external cables from the server Step 3 Remove the storage book from the server see Removing the storage book on page 273 Step 4 If a backplane filler panel is installed in the backplane bay in which you are installing the backplane remove the backplane filler panel Step 5 Insert the backplane tabs into the slots on the left side of the backplane cage and rotate t...

Page 128: ... that you connect the shorter blue power cable connector to the bottom backplane and connect the grey power cable connector to the top backplane Step 7 Connect the SAS SATA signal cable to the backplane and to the adapter If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 117 114 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 129: ...rive backplane consider the following information The 4x2 5 inch NVMe PCIe Gen3 solid state drive backplane can support up to four 2 5 inch NVMe PCIe solid state drives You can install one 4x2 5 inch NVMe PCIe Gen3 solid state drive backplane Install the 4x2 5 inch NVMe PCIe Gen3 solid state drive backplane in the top backplane bay only You can install an additional SAS SATA backplane in the lower...

Page 130: ...ort 0 to backplane port 2 Connect adapter port 1 to backplane port 3 To install the 4x2 5 inch NVMe PCIe Gen3 solid state drive backplane complete the following steps Step 1 Before you begin read Safety on page v and Installation guidelines on page 44 Step 2 Turn off the server see Turning off the server on page 40 and all attached peripheral devices Disconnect all power cords then disconnect all ...

Page 131: ... server configuration tasks that you might need to perform when you add and remove devices When you start the server for the first time after you add or remove a device you might receive a message that the configuration has changed The Setup utility starts automatically so that you can save the new configuration settings Some optional devices have device drivers that you must install For informati...

Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 133: ...ed with the downloaded update These files contain important information about the update and the procedure for installing the update including any special procedure for updating from an early firmware or device driver version to the latest version You can install code updates that are packaged as an UpdateXpress System Pack or UpdateXpress CD image An UpdateXpress System Pack contains an integrati...

Page 134: ...allation of your operating system For information about using this CD see Using the ServerGuide Setup and Installation DVD on page 121 Integrated management module Use the integrated management module II IMM2 for configuration to update the firmware and sensor data record field replaceable unit SDR FRU data and to remotely manage a network For information about using the IMM see Using the integrat...

Page 135: ...o restart the server to run the Setup utility For more information about using this program see Advanced Settings Utility program on page 140 Using the ServerGuide Setup and Installation DVD This topic provides information about using the ServerGuide Setup and Installation DVD The Lenovo ServerGuide Setup and Installation DVD provides software setup tools and installation tools that are designed f...

Page 136: ...etup program provides a list of tasks that are required to set up your server model On a server with a ServeRAID adapter or SAS SATA controller with RAID capabilities you can run the SAS SATA RAID configuration program to create logical drives Note Features and functions can vary slightly with different versions of the ServerGuide program Typical operating system installation This topic provides i...

Page 137: ...ons on how to start the server Setup utility To start the Setup utility complete the following steps Step 1 Turn on the server Note Approximately 10 seconds after the server is connected to input power the power on button becomes active Step 2 When the prompt F1 Setup is displayed press F1 If you have set an administrator password you must type the administrator password to access the full Setup u...

Page 138: ...equivalent to disconnecting the device Driver Health Select this choice to view the health of the controllers in the server as reported by their device drivers Integrated Management Module Select this choice to view or change the settings for the integrated management module Power Restore Policy Select this choice to determine the mode of operation to which the server will be restored after a powe...

Page 139: ...of the system during operation Server performance in this mode might be reduced depending on the application that is running Efficiency Favor Power mode Select this choice to configure the server to draw the minimum amount of power and generate the least noise Server performance might be degraded depending on the application that you are running This mode provides the best features for reducing po...

Page 140: ...the recovery is started System Recovery Select this choice to view or set the time to start the system recovery attempt POST Watchdog Timer Select this choice to view or enable the POST watchdog timer Reboot System on NMI Select this choice to enable or disable restarting the server whenever a nonmaskable interrupt NMI occurs The default is Enabled Halt On Server Error Select this choice to preven...

Page 141: ...essages in the POST event log System Event Log Select this choice to view the system event log Clear System Event Log Select this choice to clear the system event log User Security Select this choice to set change or clear passwords The full Setup utility menu enables all of the options in the User Security option See Passwords on page 128 for more information This choice is on the full and limite...

Page 142: ...e system startup A system administrator who types the administrator password has access to the full Setup utility menu the system administrator can give the user authority to set change and delete the power on password A user who types the power on password has access to only the limited Setup utility menu the user can set change and delete the power on password if the system administrator has giv...

Page 143: ...rd override switch does not affect the administrator password Administrator password This topic provides information about setting an administrator password using the server Setup utility If an administrator password is set you must type the administrator password for access to the full Setup utility menu You can use any combination of 6 to 20 printable ASCII characters for the password Attention ...

Page 144: ...o ON See Jumpers switches and buttons on standard I O book board on page 37 for more information about the jumpers switches and buttons on the server The following illustration shows the location of the SW1 switch block NMI button SW1 switch block SW2 switch block reserved IMM security jumper J35 8 7 6 5 4 3 2 1 OFF ON 1 2 3 Use the backup copy of the server firmware until the primary copy is rest...

Page 145: ...minimum of four power supplies two power supplies in each node Before you create a multinode system make sure that all the nodes in the multinode configuration contain the following software and hardware The current level of UEFI firmware and IMM firmware all nodes must be at the same level Microprocessors that are the same cache size type and clock speed To check for the latest firmware levels an...

Page 146: ...see Logging on to the IMM web interface on page 135 For more information about using IMM2 the IMM2 web interface and the IMM2 telnet interface to manage and partition the server see Using the integrated management module on page 133 and the Integrated Management Module II User s Guide at https systemx lenovofiles com help topic com lenovo sysx imm2 doc printable_doc html 132 System x3850 X6 and x3...

Page 147: ...operating system watchdog timer times out The IMM might be configured to watch for the operating system watchdog timer and reboot the system after a timeout if the ASR feature is enabled Otherwise the IMM allows the administrator to generate a nonmaskable interrupt NMI by pressing an NMI button on the rear of the server for an operating system memory dump ASR is supported by IPMI Remote presence s...

Page 148: ...e following functions Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz regardless of the system state Remotely accessing the server using the keyboard and mouse from a remote client Mapping the CD or DVD drive diskette drive and USB flash drive on a remote client and mapping ISO and diskette image files as virtual drives that are available for use by the server Uploading...

Page 149: ...also obtain the IMM host name MAC address and IP address from the LCD display panel See LCD system information display panel on page 27 for more information Step 1 Turn on the server Note Approximately 10 seconds after the server is connected to ac power the power on button becomes active Step 2 When the prompt F1 Setup is displayed press F1 This prompt is displayed on the screen for only a few se...

Page 150: ...ws 2008 console This might also affect blue screen capture features netsh firewall set icmpsetting type 8 mode ENABLE By default the icmp packet is blocked by Windows firewall The IMM GUI will then change to OS booted status after you change the setting as indicated above in both the Web and CLI interfaces Step 1 From the command prompt type telnet then the IP address for the IMM to which you want...

Page 151: ...stem Power Configurations You cannot use UEFI to change Power Policy and System Power Configurations The power configurations and policies can be changed using IMM2 web interface CIM or Advanced Settings Utility ASU Five N N configurations are supported for 1 1 and 2 2 as listed in the System power configuration screen on IMM2 web interface For redundancy the input feeds must be wired with separat...

Page 152: ...t how to enable the embedded hypervisor software on the USB flash device The VMware ESXi embedded hypervisor software is available on the optional USB flash device with embedded hypervisor The USB flash device can be installed in USB flash device connector on the Standard I O book see Standard I O book on page 31 for the location of the connector Hypervisor is virtualization software that enables ...

Page 153: ...e to set any jumpers or configure the controller However you must install a device driver to enable the operating system to address the controller For device drivers and information about configuring the Ethernet controller go to http datacentersupport lenovo com Enabling Features on Demand Ethernet software This topic provides information about enabling Features on Demand Ethernet software You ca...

Page 154: ...gs Use the ASU program online or out of band to modify UEFI settings from the command line without the need to restart the system to access the Setup utility You can also use the ASU program to configure the optional remote presence features or other IMM settings The remote presence features provide enhanced systems management capabilities In addition the ASU program provides limited settings for ...

Page 155: ...r is installed by default The Advanced Settings Utility ASU provides the corresponding mapping layer To update the UUID in the ASU command line interface enter the following command asu set SYSTEM_PROD_DATA SysInfoUUID uuid where uuid is the user assigned hexadecimal value up to 16 bytes that identifies the server To update the DMI SMBIOS data complete the following steps Step 1 In the ASU command...

Page 156: ...IMM The default is 169 254 95 118 userid is the IMM account name 1 of 12 accounts The default is USERID password is the IMM account password 1 of 12 accounts The default is PASSW0RD with a zero not the letter O Step 2 Enter the following command asu set SYSTEM_PROD_DATA SysInfoSerialNum zzzzzzz host ipaddress user userid password password where zzzzzzz is the 7 character serial number of the serve...

Page 157: ...ord where xxxx is the 4 digit machine type of the server yyy is the 3 digit model number of the server ipaddress is the external LAN IP address of the IMM userid is the IMM account name 1 of 12 accounts The default is USERID password is the IMM account password 1 or 12 accounts The default is PASSW0RD with a zero not the letter O Step 2 Enter the following command asu set SYSTEM_PROD_DATA SysInfoS...

Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 159: ...curred if possible reverse those changes This might include any of the following items Hardware components Device drivers and firmware System software UEFI firmware System input power or network connections Step 2 View the light path diagnostics LEDs and event logs The server is designed for ease of diagnosis of hardware and software problems Light path diagnostics LEDs See Light path diagnostics ...

Page 160: ...an the release date of the UpdateXpress System Pack or UpdateXpress image see step b b Install manual system updates 1 Determine the existing code levels In DSA click Firmware VPD to view system firmware levels or click Software to view operating system levels 2 Download and install updates of code that is not at the latest level To display a list of available updates for the server go to http dat...

Page 161: ... service provider for assistance with additional problem determination and possible hardware replacement To open an online service request go to https www ibm com support servicerequest Home action Be prepared to provide information about any error codes and collected data Undocumented problems If you have completed the diagnostic procedure and the problem remains the problem might not have been p...

Page 162: ...e whether the failing server is part of a shared hard disk drive cluster two or more servers sharing external storage devices If it is part of a cluster you can run all diagnostic programs except the ones that test the storage unit that is a hard disk drive in the storage unit or the storage adapter that is attached to the storage unit The failing server might be part of a cluster if any of the fo...

Page 163: ...ices g Turn on the server If the server does not start see Troubleshooting by symptom on page 170 h Check the system error LED on the operator information panel If it is lit check the light path diagnostics LEDs see Light path diagnostics on page 152 i Check for the following results Successful completion of POST see POST on page 164 for more information Successful completion of startup which is i...

Page 164: ...ystem component fails the IMM lights LEDs to help you diagnose the problem records the error in the IMM event log and alerts you to the problem Optionally the IMM also provides a virtual presence capability for remote server management capabilities The IMM provides remote server management through the following industry standard interfaces Intelligent Platform Management Protocol IPMI version 2 0 ...

Page 165: ... server DSA Preboot collects and analyzes system information to aid in diagnosing server problems as well as offering a rich set of diagnostic tests of the major components of the server DSA Preboot collects the following information about the server Drive health information Event logs for ServeRAID controllers and service processors Installed hardware including PCI and USB information Light path ...

Page 166: ...rror has occurred go to step 2 Note Reset button Press this button on the front operator panel to reset the server and run the power on self test POST You might have to use a pen or the end of a straightened paper clip to press the button 2 The modules in the server on the front and rear have LEDs that are lit to indicate the location of a problem In addition to the light path diagnostic LEDs the ...

Page 167: ...ge 158 Storage book LEDs Use this information to determine the location of the LEDs on the storage book The following illustration shows the location of the LEDs on the storage book Storage book Reset button Power button LED Locate button LED Check log LED System error LED PCIe slot 11 error LED PCIe slot 12 error LED Board error LED Drive activity LED green Drive status LED yellow Chapter 4 Troub...

Page 168: ...ine the location of the LEDs on the compute book The following illustration shows the location of the LEDs on the compute book Fan LEDs Power LED Error LED Compute book Light path button 154 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 169: ...essor side of the compute book board Left side of board DIMM 1 3 error LEDs DIMM 7 12 error LEDs DIMM 4 6 error LEDs Light path power LED Microprocessor error LED Board error LED The following illustration shows the location of the DIMM LEDs on the non microprocessor side of the compute book board Right side of board DIMM 19 21 error LEDs DIMM 13 18 error LEDs DIMM 22 24 error LEDs Chapter 4 Troub...

Page 170: ...k Half length I O book LEDs Use this information to determine the location of the half length I O book LEDs The following illustration shows the location of the half length I O book LEDs Half length I O book I O board error LED Slot power LEDs Slot error LEDs Power button 156 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 171: ...or LEDs Power button Standard I O book LEDs Use this information to determine the location of the LEDs on the standard I O book The following illustration shows the location of the LEDs on the standard I O book Fan pack 9 error LED NMI button 3V battery error LED I O board error LED Locate LED System power LED System error LED Fan pack 10 error LED Ethernet activity LED Ethernet link LED Slot erro...

Page 172: ...rver to start A minimum of four compute books two in each node with E7 8xxx microprocessors The microprocessors must be of the same cache size type and clock speed The 8 socket chassis Two standard I O books Two storage books A minimum of four power supplies two power supplies in each node The following illustration shows the locations of the power supply LEDs Power connector AC power LED green DC...

Page 173: ...em is off The system is connected to power The server is functioning correctly The system is on Power supply not fully seated faulty standard I O book or faulty power supply 1 Reseat the power supply 2 Replace the power supply 3 Replace the standard I O book Typically indicates a power supply is not fully seated On Off On Faulty power supply Replace the power supply On On On Power supply is faulty...

Page 174: ... powered on but not in use Drive status LEDs These LEDs are on SAS or SATA hard disk drives and solid state drives When one of these LEDs is lit it indicates that the drive has failed When this LED is flashing slowly one flash per second it indicates that the drive is being rebuilt When the LED is flashing rapidly three flashes per second it indicates that the controller is identifying the drive E...

Page 175: ...ntents of the POST event log from the Setup utility see Starting the Setup utility on page 123 For more information about POST error codes see Appendix D UEFI POST error codes on page 1925 System event log This log contains POST and system management interrupt SMI events and all events that are generated by the baseboard management controller that is embedded in the integrated management module IM...

Page 176: ...tor password to view the event logs Step 3 Select System Event Logs and use one of the following procedures To view the POST event log select POST Event Viewer To view the system event log select System Event Log Viewing event logs without restarting the server Use this information to learn how to view event logs without restarting the server If the server is not hung and the IMM is connected to a...

Page 177: ...interface on page 135 The integrated management module IMM is connected to a network and ac power is applied The server state might be hung not hung or powered off Use any of the following methods Use IPMItool over the network to the IMM external IP address to view the system event log Use the web browser interface to the IMM to view the system event log In the Web browser type the IP address for ...

Page 178: ...vo Dynamic System Analysis program Lenovo Dynamic System Analysis DSA collects and analyzes system information to aid in diagnosing server problems DSA collects the following information about the server Drive health information Event logs for ServeRAID controllers and service processors Hardware inventory including PCI and USB information Installed applications and hot fixes available in DSA Port...

Page 179: ... Preboot DSA Preboot runs outside of the operating system you must restart the server to run it It is provided in the flash memory on the server or you can create a bootable media such as a CD DVD ISO USB or PXE using the Lenovo ToolsCenter Bootable Media Creator BoMC For more details see the BoMC User Guide at https support lenovo com solutions LNVO BOMC In addition to the capabilities of the oth...

Page 180: ... on the screen to select the diagnostic test to run If the server stops during testing and you cannot continue restart the server and try running the DSA Preboot diagnostic programs again If the problem remains replace the component that was being tested when the server stopped Diagnostic text messages This topic provides a description of the diagnostic text messages results Diagnostic text messag...

Page 181: ... sends that data to Lenovo Service for problem determination It also includes the call home feature that automatically calls Lenovo Service when a problem occurs The Service Advisor feature is integrated into the Integrated Management Module II IMM2 You will need to setup and configure the Service Advisor feature before you can use it For more information about how to setup and configure the Servi...

Page 182: ... to your tftp server or sftp server 5 Type exit to exit the session when you are done Capturing the FFDC log using IPMI commands This topic provides instructions for using the IPMI commands to capture the FFDC log data To generate and download the first failure data capture FFDC log data using IPMI commands complete the following steps 1 From a host system type the command ipmitool I lanplus H 169...

Page 183: ...he messages that might display on the LCD system information display panel during POST and the actions to take to correct the problem see Appendix A LCD display panel messages on page 339 Chapter 4 Troubleshooting 169 ...

Page 184: ... new optional device and the server is not working complete the following steps before you use the troubleshooting tables 1 Check the system error LED on the operator information panel if it is lit check the light path diagnostics LEDs see Light path diagnostics on page 152 2 Remove the software or device that you just added 3 Run Dynamic System Analysis DSA to determine whether the server is runn...

Page 185: ...l setup complete the following steps 1 Make sure that a The I O adapter is powered on and the ports are enabled b All cables between the I O adapter and the network device switch or router are connected correctly and secure and that the activity LEDs are lit on the applicable ports 2 From the server operating system verify the adapter network settings IP address subnet mask if using IPv4 DHCP and ...

Page 186: ...n to the IMM then do the following a If the IMM is proven accessible by system administrator verify the login information b If the IMM is not accessible by system administrator reset the IMM to defaults through the Setup utility c Retry the login If IMM is still not accessible replace the standard I O book see Removing the standard I O book on page 224 and Replacing the standard I O book on page 2...

Page 187: ...mponents are field replaceable units FRU If an action step is preceded by Trained service technician only that step must be performed only by a Trained service technician Symptom Action The server fails to recognize one drive 1 Verify that the drive is supported for this server Check the ServerProven web site at http www lenovo com serverproven for a list of supported hard drives 2 Make sure that ...

Page 188: ... backplane 4 Observe the associated green hard disk drive activity LED and the amber status LED If the green activity LED is flashing and the amber status LED is not lit the drive is recognized by the controller and is working correctly Run the DSA hard disk drive test to determine whether the drive is detected see Running the DSA Preboot diagnostic programs on page 166 If the green activity LED i...

Page 189: ...er was recently installed moved or serviced make sure that the drives are seated correctly the backplane cables are securely connected to the backplane and the storage book board and the RAID adapter is configured correctly 2 Make sure that there is no physical damage to the drive connectors backplanes or cables make sure the cables are not pinched or damaged 3 Verify that the drives are supported...

Page 190: ...vity LED is flashing If it is not recognized see A newly installed hard disk drive is not recognized symptom actions to set the RAID configuration1 on page 174 3 Review the SAS SATA RAID adapter documentation to determine the correct configuration parameters and settings An amber hard disk drive status LED does not accurately represent the actual state of the associated drive 1 If the server was r...

Page 191: ...ervice technician Symptom Action If an optional embedded hypervisor flash device is not listed in the expected boot order does not appear in the list of boot devices or a similar problem has occurred 1 Make sure that the optional embedded hypervisor flash device is selected on the boot manager F12 Select Boot Device at startup 2 Make sure that the embedded hypervisor flash device is seated in the ...

Page 192: ...vers are installed See the manufacturer s website for documentation 2 For a USB device complete the following steps a Make sure that the device is configured correctly see Using the Setup utility on page 123 b Connect the device to another port If using a USB hub remove the hub and connect the device directly to the server Make sure that the device is configured correctly for the port see Using th...

Page 193: ...3 If you are using a USB keyboard and it is connected to a USB hub disconnect the keyboard from the hub and connect it directly to the server 4 If you are using a USB keyboard and it is connected to a USB hub disconnect the keyboard from the hub and connect it directly to the server If connected directly to the server try another port If the keyboard works replace the USB hub 5 Replace the keyboar...

Page 194: ...e seated correctly 2 If a new DIMM has been installed recently verify that you have not received any configuration events in the event log Otherwise check the IMM event log If any DIMM configuration events are listed resolve the DIMM event problems first 3 Make sure that No error LEDs are lit on the operator information panel or on the compute book Memory mirroring does not account for the discrep...

Page 195: ...units FRU If an action step is preceded by Trained service technician only that step must be performed only by a Trained service technician Symptom Action The server goes directly to the POST event viewer when it is turned on Check the IMM event log and resolve any errors that have occurred Monitor and video problems Use this information to solve monitor and video problems Some monitors have their...

Page 196: ...to the correct connector on the rear of the server If the video now works replace the KVM switch 3 Replace the standard I O book The monitor works when you turn on the server but the screen goes blank when you start some application programs 1 Make sure that The application program is not setting a display mode that is higher than the capability of the monitor You installed the necessary device dr...

Page 197: ...nstalled verify that it is supported by the server see http www lenovo com serverproven 2 Verify the network adapter slot power state and configuration see Using the Setup utility on page 123 3 Check to make sure that the server is properly connected to the network and that there is no damage to the network cables 4 Check the firmware device driver 5 Check the Retain Tips for related issues on the...

Page 198: ...g air noise Check the IMM event log for events associated with thermals cooling and fans Power supply Clicking or rattling noise 1 If the server is running redundant power pull and replace each power supply one at a time to determine which power supply is causing the noise 2 If a single power supply is identified as causing the problem complete the following steps a Make sure that the power supply...

Page 199: ...eplacing components on page 221 Server is unresponsive POST is complete and operating system is running If you are in the same location as the server complete the following steps 1 If you are using a KVM connection make sure that the connection is operating correctly Otherwise make sure that the keyboard and mouse are operating correctly 2 If possible log in to the server and verify that all appli...

Page 200: ...is preceded by Trained service technician only that step must be performed only by a Trained service technician Symptom Action Unusual smell Complete the following steps until the problem is solved 1 An unusual smell might be coming from newly installed equipment 2 If the problem remains contact Lenovo Support Server seems to be running hot Make sure that the room temperature is within the specifi...

Page 201: ...t you just installed An optional device that worked previously does not work now 1 Check the IMM event log for any events associated with the device 2 Make sure that all of the cable connections for the device are secure 3 If the device comes with test instructions use those instructions to test the device 4 If the failing device is a SCSI device make sure that The cables for all external SCSI dev...

Page 202: ...llowing steps a Check the IMM event log for any power faults and to ensure that the power state matches the power LED b Check the power supply LEDs and address any power fault issues c Press the power on button to attempt to restore power d Attempt to restore power remotely If power is restored replace the front operator panel e Remove ac power input to the server for 20 seconds and power on the s...

Page 203: ... 49 Symptoms and user actions for serial device problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved See Chapter 5 Parts listing System x3850 X6 and x3950 X6 Type 6241 on page 201 to determine which components are customer replaceable units CRU and which components are field replaceable units FRU If an action step is preceded ...

Page 204: ...ct all installed drives or the operating system cannot be installed 1 Make sure that the hard disk drive is connected correctly 2 Make sure that the SAS SATA hard disk drive cables are securely connected 3 Follow the steps in A newly installed hard disk drive is not recognized 1 on page 174 symptom actions in the Hard disk drive problems on page topic The operating system installation program cont...

Page 205: ...ently been installed moved or serviced or if this is the first time the embedded hypervisor is being used make sure that the device is connected properly and that there is no physical damage to the connectors see Removing a USB embedded hypervisor flash device on page 252 and Replacing a USB embedded hypervisor flash device on page 254 2 Check the Lenovo ServerProven web site at http www lenovo co...

Page 206: ... log for messages associated with the restart event and resolve the issue Some correctable errors require that the server reboots so that it can disable a device such as a memory DIMM or a microprocessor to allow the machine to boot up properly 2 If the server restart occurs during POST and the POST watchdog timer is enabled select System Settings Recovery System Recovery POST Watchdog Timer in th...

Page 207: ...y events related to your software and attempt to resolve them 4 Contact your software provider for additional problem resolution 5 Contact the software vendor Universal Serial Bus USB port problems Use this information to solve Universal Serial Bus USB port problems Table 53 Symptoms and user actions for USB port problems Follow the suggested actions in the order in which they are listed in the Ac...

Page 208: ...tem you are using See the operating system documentation for information about Ethernet controllers and see the Ethernet controller device driver readme file Try the following procedures Make sure that the correct device drivers which come with the server are installed and that they are at the latest level Make sure that the Ethernet cable is installed correctly The cable must be securely attached...

Page 209: ...tly Step 3 Remove or disconnect the following devices one at a time until you find the failure Turn on the server and reconfigure it each time Any external devices Surge suppressor device on the server Printer mouse and non Lenovo devices Each adapter Hard disk drives Memory modules The minimum configuration requirement is one DIMM in each compute book Step 4 Turn on the server If the problem is s...

Page 210: ...version level Hardware configuration print screen of the system summary UEFI firmware level IMM firmware level Operating system software You can solve some problems by comparing the configuration and software setups between working and nonworking servers When you compare servers to each other for diagnostic purposes consider them identical only if all the following factors are exactly the same in ...

Page 211: ...ive To download the server firmware update package from the World Wide Web go to http datacentersupport lenovo com Attention Installing the wrong firmware or device driver update might cause the server to malfunction Before you install a firmware or device driver update read any readme and change history files that are provided with the downloaded update These files contain important information a...

Page 212: ...d with the firmware update package Step 10 Turn off the server and disconnect all power cords and external cables Step 11 Change the position of switch 7 back to OFF the default Step 12 Reconnect all the power cables Step 13 Restart the server In band automated boot recovery method Note Use this method if the standard I O book board LED is lit and there is a log entry or Booting Backup Image is di...

Page 213: ...es such as added devices or adapter firmware updates and firmware or application code problems can cause the server to fail POST power on self test If this occurs the server responds in either of the following ways The server restarts automatically and attempts POST again The server hangs and you must manually restart the server for the server to attempt POST again After a specified number of cons...

Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 215: ...component at your request you will be charged for the service Field replaceable unit FRU FRUs must be installed only by trained service technicians unless they are classified as customer replaceable units CRUs Tier 1 customer replaceable unit CRU Replacement of Tier 1 CRUs is your responsibility If a Lenovo approved warranty service provider installs a Tier 1 CRU at your request you will be charge...

Page 216: ...5 1 14 8 7 4 5 6 3 2 9 10 12 13 11 The following is an illustration of the components in the rear of the server 16 17 18 19 20 23 24 21 22 202 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 217: ...ts listing Type 6241 Index Description CRU part number Tier 1 CRU part number Tier 2 FRU part number 1 Shuttle x3850 X6 4 socket for 4U included in part number 00FN661 2 ServeRAID M5210 SAS SATA Controller 46C9111 2 ServeRAID M5120 SAS SATA Controller 00AE811 3 Board storage I O book assembly 00D0055 4 Filler compute book 95Y4378 5 Compute book for E7 x8xx v2 and v3 series 00FN785 5 Compute book f...

Page 218: ...sk drive 2 5 inch SAS Gen3 NL hot swap 500 GB 7 2K 6 Gbps 00AJ137 9 Hard disk drive 2 5 inch SATA Gen3 NL hot swap 1 TB 7 2K 6 Gbps 00AJ142 9 Hard disk drive 2 5 inch SAS Gen3 hot swap 1 2 TB 10K 6 Gbps 00AJ147 9 Hard disk drive 2 5 inch SAS Gen3 hot swap 600 GB 15K 6Gbps for x3950 X6 8U 00AJ127 9 Hard disk drive IBM 300 GB 15K 12 Gbps SAS 2 5 inch G3HS 512e 00NA222 9 Hard disk drive IBM 600 GB 15...

Page 219: ...ps SAS 2 5 inch G3HS 512e 00NA302 Self encrypting drive SED IBM 1 8 TB 10K 12 Gbps SAS 2 5 inch G3HS 512e 00NA307 Self encrypting drive SED IBM 300 GB 15K 12 Gbps SAS 2 5 inch G3HS 512e Hybrid 00NA312 Self encrypting drive SED IBM 600 GB 15K 12 Gbps SAS 2 5 inch G3HS 512e Hybrid 00NA322 Self encrypting drive SED 2 5 inch SAS Gen3 hot swap 900 GB 10K 6 Gbps 00AJ077 Self encrypting drive SED 2 5 inc...

Page 220: ...ATA Gen3 MLC hot swap 240 GB for x3950 X6 8U 00AJ401 Solid state drive Enterprise Value 2 5 inch SATA Gen3 MLC hot swap 480 GB for x3950 X6 8U 00AJ406 Solid state drive Enterprise Value 2 5 inch SATA Gen3 MLC hot swap 800 GB for x3950 X6 8U 00AJ411 Solid state drive P3600 400GB NVMe 2 5 inch G3HS Enterprise Value PCIe for System x 90Y3228 Solid state drive P3600 800 GB NVMe 2 5 inch G3HS Enterpris...

Page 221: ...ue 1 8 inch SATA MLC 800 GB for x3950 X6 8U 00AJ351 Solid state drive 1 92TB Value NVMe 2 5 PCIe 01GR661 Solid state drive 3 84TB Value NVMe 2 5 PCIe 01GT716 Solid state drive S3510 120GB Enterprise Entry SATA 2 5 inch Gen3 hot swap 00WG621 Solid state drive S3510 240GB Enterprise Entry SATA 2 5 inch Gen3 hot swap 00WG626 Solid state drive S3510 480GB Enterprise Entry SATA 2 5 inch Gen3 hot swap 0...

Page 222: ...5 inch Gen4 hot swap 00YK289 Solid state drive 1 92TB Enterprise Mainstream PCIe x4 2 5 inch HHHL card 00YK290 Solid state drive 3 84TB Enterprise Capacity 6Gb SAS MLC Gen3 hot swap 00NA672 Solid state drive 3 84TB Enterprise Capacity 12Gb SAS Gen3 hot swap 01GR787 Solid state drive 3 84TB Enterprise Mainstream PCIe x4 2 5 inch HHHL card 00YK291 Solid state drive P3700 400GB Enterprise Performance...

Page 223: ...ve included in part number 95Y4383 14 Chassis and shuttle x3850 X6 4 socket 4U assembly 00FN661 Chassis and shuttle x3950 X6 8 socket 8U assembly 00FN662 15 Midplane x3850 X6 4 socket for 4U chassis 00D0051 16 Fan rear hot swap 00WC276 17 I O book X6 standard with fan cable and air duct 00YA701 18 I O book X6 half length models A4X H1X 00FN822 19 I O book X6 full length with brackets and two suppl...

Page 224: ...ys 95Y4383 Hard disk drive backplane filler 69Y2286 Front operator panel assembly include bracket light pipe assembly 00FG825 Handles cam front 00FN594 Handles cam rear 00FN595 Labels 4U 00WC269 Labels 8U 00WC270 LCD display panel 00D0464 Memory 4 GB 2 Gb 1Rx4 1 35 V PC3 12800 DDR3 ECC 1600 MHz LP RDIMM 00D5026 Memory 8 GB 4 Gb 1Rx4 l 35 V PC3 12800 DDR3 ECC 1600 MHz LP RDIMM 00D5038 Memory 16 GB ...

Page 225: ...DIMM eXFlash 400 GB DDR3 90Y3247 Heatsink assembly for DDR3 compute book 95Y4388 Heatsink assembly for DDR4 compute book 00FN671 Microprocessor 1 9 GHz 12 MB 105W 6C E7 4809 v2 44X3963 Microprocessor 2 0 GHz 16 MB 105W 8C E7 4820 v2 44X3968 Microprocessor 2 2 GHz 20 MB 105W 10C E7 4830 v2 44X3973 Microprocessor 2 3 GHz 24 MB 105W 12C E7 4850 v2 44X3978 Microprocessor 2 6 GHz 30 MB 130W 12C E7 4860...

Page 226: ...icroprocessor E7 8880L v3 00FP686 Microprocessor E7 8891 v3 00FP687 Microprocessor E7 8893 v3 00FP688 Microprocessor E7 8867 v3 00FP689 Microprocessor E7 4809 v4 00MT484 Microprocessor E7 4820 v4 00MT485 Microprocessor E7 4850 v4 00MT487 Microprocessor E7 8860 v4 00MT489 Microprocessor E7 8870 v4 00MT490 Microprocessor E7 8890 v4 00MT492 Microprocessor E7 4830 v4 00MT486 Microprocessor E7 8880 v4 ...

Page 227: ...ed in systems with 1TB of memory or more it might cause undetected data corruption and system instability This option is only supported in systems containing less than 1TB of memory This limitation applies to both the 4 socket 4U and the 8 socket 8U configurations 90Y2395 NVIDIA Quadro K4000 PCI Express x16 Adapter Note Do not install this adapter in systems containing 1TB of system memory or more...

Page 228: ... system memory or more If this option is installed in systems with 1TB of memory or more it might cause undetected data corruption and system instability This option is only supported in systems containing less than 1TB of memory This limitation applies to both the 4 socket 4U and the 8 socket 8U configurations 90Y2391 NVIDIA Tesla K40c PCI Express x16 Adapter Note Do not install this adapter in s...

Page 229: ...er 47C8671 ServeRAID M5100 Series 512 MB Flash RAID 5 Adapter 46C9027 ServeRAID Cache Flash SuperCap 00JY023 ServeRAID M5225 2 GB SAS SATA Controller 00AE939 N2225 SAS SATA HBA for IBM System x 00AE914 N2226 SAS SATA HBA for IBM System x 00KH483 IBM 1 2 TB High IOPS MLC Mono Adapter 90Y4378 IBM 2 4 TB High IOPS MLC Duo Adapter 90Y4398 IBM 365 GB High IOPS MLC Mono Adapter 46C9079 IBM 785 GB High I...

Page 230: ...3340 Qlogic 16GB FC single port HBA for Lenovo System X 01CV753 Qlogic 16 GB FC dual port HBA FOR IBM SYSTEM X 00Y3344 Qlogic 16GB FC dual port HBA for Lenovo System X 01CV763 Emulex 16 GB FC single port HBA 00D8546 Emulex 16 GB FC dual port HBA 00JY849 Emulex 16 GB FC single port HBA 81Y1658 Emulex 16 GB FC dual port HBA 81Y1665 Emulex 16 Gb FC single port HBA 01CV833 Emulex 16 Gb FC dual port HB...

Page 231: ...System x 00D9552 Mellanox 10 GbE Adapter for IBM System x 00D9692 Mellanox CX4 LX ML2 1x25GbE Adapter 00MN993 Mellanox ConnectX 4 EDR IB VPI Single port x16 PCIe 3 0 HCA 00KH926 Broadcom NetXtreme 2x10 GbE BaseT Adapter for IBM System x 95Y3759 Qlogic 8200 Dual Port 10 GbE SFP VFA for IBM System x 90Y4605 Brocade 10 Gb SFP SR Optical Transceiver 46C9297 Qlogic 10 Gb SFP SR Optical Transceiver 42C1...

Page 232: ...lash Power Module Kit 81Y4579 To order a consumable part complete the following steps Note Changes are made periodically to the World Wide Web The actual procedure might vary slightly from what is described in this document 1 Go to http www lenovo com 2 From the Support menu select Support resources 3 Select Data Center as the product family 4 Enter a machine type of 6241 and select System x3850 X...

Page 233: ...stria Azerbaijan Belarus Belgium Benin Bosnia and Herzegovina Bulgaria Burkina Faso Burundi Cambodia Cameroon Cape Verde Central African Republic Chad Comoros Congo Democratic Republic of Congo Republic of Cote D Ivoire Ivory Coast Croatia Republic of Czech Republic Dahomey Djibouti Egypt Equatorial Guinea Eritrea Estonia Ethiopia Finland France French Guyana French Polynesia Germany Greece Guadel...

Page 234: ...ua Panama Peru Philippines Saudi Arabia Thailand Taiwan United States of America Venezuela 39M5076 110 120 V Antigua and Barbuda Aruba Bahamas Barbados Belize Bermuda Bolivia Caicos Islands Canada Cayman Islands Colombia Costa Rica Cuba Dominican Republic Ecuador El Salvador Guam Guatemala Haiti Honduras Jamaica Mexico Micronesia Federal States of Netherlands Antilles Nicaragua Panama Peru Philipp...

Page 235: ...by a trained service technician For information about the terms of the warranty see the Lenovo Warranty Information document that comes with the server For more information about getting service and assistance see Appendix E Getting help and technical assistance on page 1951 Returning a device or component This topic provides information about returning a device or component If you are instructed ...

Page 236: ...or and DIMMs 1 through 12 remove the left cover To access DIMMs 13 through 24 remove the right cover To remove the compute book covers complete the following steps Step 1 Before you begin read Safety on page v and Installation guidelines on page 44 Step 2 Turn off the server see Turning off the server on page 40 and all attached peripheral devices Disconnect all power cords then disconnect all ext...

Page 237: ... replace the compute book covers The compute book has a cover on the left side and a cover on the right side for access to the microprocessor and DIMMs Use the same procedure to remove both covers To access the microprocessor and DIMMs 1 through 12 remove the left cover To access DIMMs 13 through 24 remove the right cover To replace the compute book covers complete the following steps Step 1 Align...

Page 238: ...nt information needed to complete the replacement This information must then be manually gathered by disassembling components and reading the information on component labels Links are provided to removal and replacement procedures that provide label access for components external to the standard I O book such as the front operator panel assembly LCD system information display panel and midplane 1 ...

Page 239: ... in any of the following Customer records Service offering support information Component VPD file saved using the Advanced Settings Utility ASU For more information about using ASU and additional command options see Advanced Settings Utility program on page 140 Save component VPD information Use the following ASU command to save component VPD information asu64 show VPD component_vpd where componen...

Page 240: ...ram on page 140 Save component VPD information Use the following ASU command to save component VPD information asu64 show VPD component_vpd where component_vpd is the complete path name of the file where the component VPD information is to be saved The 4 socket midplane is the component with extension 1 and the 8 socket midplane is the component with extension 2 in the saved component VPD file Exi...

Page 241: ...t do not come with a flash power module can also be installed in the standard I O book You can install up to three flash power modules in the standard I O book You can install only ML2 Ethernet adapters in PCIe slot 10 of the standard I O book See Supported ML2 Ethernet adapters on page 88 for more information about the Ethernet adapters When you replace the standard I O book you must either updat...

Page 242: ...evice see Replacing a USB embedded hypervisor flash device on page 254 4 Install the adapters see Replacing an adapter on page 238 5 Cable the adapters 6 Close the adapter retention lever 7 Install the fans see Replacing a hot swap fan assembly on page 260 8 Grasp the standard I O book and align it with the slot on the server and slide it into the chassis shuttle Handle Handle Standard I O book 9 ...

Page 243: ... Update the system serial number VPD Use the following ASU command to update the system serial number VPD asu64 set SYSTEM_PROD_DATA SysInfoSerialNum serial_number where serial_number is the 7 character system product serial number Update the system UUID VPD Use the following ASU command to update the system UUID VPD asu64 set SYSTEM_PROD_DATA SysInfoUUID uuid where uuid is the 16 character hexade...

Page 244: ...umber VPD Use the following ASU commands to update the component serial number and prefix serial number VPD asu64 set VPD CompVPD_SerialNumber 4 s n asu64 set VPD CompVPD_PrefixSerialNumber 4 prefix_s n where s n is the 6 character component serial number prefix_s n is the 6 character component prefix serial number Update the FRU part number VPD Use the following ASU command to update the FRU part...

Page 245: ...rmware or device driver update read any readme and change history files that are provided with the downloaded update These files contain important information about the update and the procedure for installing the update including any special procedure for updating from an early firmware or device driver version to the latest version 17 Restart the IMM2 then restart the server Removing the standard...

Page 246: ... Step 7 If you are instructed to return the module follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the standard I O book air baffle Use this information for instructions on how to replace the standard I O book air baffle The air baffle is located in the standard I O book To install the air baffle complete the following steps 232 Sys...

Page 247: ...server with an air baffle removed might damage server components Removing the half length I O book This information provides instructions for removing the half length I O book To remove the half length I O book complete the following steps Step 1 Before you begin read Safety on page v and Installation guidelines on page 44 Step 2 The half length I O book is hot swappable if no adapters are install...

Page 248: ...and information that you must consider when install this I O book see Installing the half length I O book on page 79 If you are replacing the half length I O book with a full length I O book see Installing the full length I O book on page 80 To replace the half length I O book complete the following steps Step 1 Reinstall the adapters see Installing an adapter on page 83 Step 2 Close the adapter r...

Page 249: ...he full length I O book complete the following steps Step 1 Before you begin read Safety on page v and Installation guidelines on page 44 Step 2 The full length I O book is hot swappable if no adapters are installed in the I O book If adapters are installed in the I O book you must first press the Power button on the I O book and power off all three PCIe adapter slots before you remove the I O boo...

Page 250: ...ok on page 79 The ability to hot add the full length I O book is dependent on the operating system If the operating system does not support hot plug the addition or removal of a full length I O book might cause an unrecoverable system error Attention If the I O bay is not populated with a full length I O book when the operating system boots or the operating system is still running a full length I ...

Page 251: ...ines on page 44 Step 2 Turn off the server see Turning off the server on page 40 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the I O book in which the failed adapter is installed Follow the removal instructions as documented for the I O book Step 4 Disconnect any cables from the adapter Step 5 L...

Page 252: ...the connector on the board before you turn on the server An incorrectly seated adapter might cause damage to the board or the adapter Step 7 Close the adapter retention lever to secure the adapter in place Step 8 Connect any cables to the adapter if necessary Step 9 Reinstall the I O book in the server Step 10 Perform any configuration tasks that are required for the adapter Step 11 Reconnect the ...

Page 253: ... swap drive a Remove the filler panel b Grasp the orange and black release latch on the drive tray handle for the drive that you want to remove and slide the release latch down to unlock the drive tray handle then rotate the drive tray handle to the right and the pull the handle toward you to slide the drive out of the bay Lift the drive out of the drive tray Chapter 6 Removing and replacing compo...

Page 254: ...rts 2 5 inch hot swap SAS or hot swap SATA hard disk drives 2 5 inch hot swap solid state drive or 1 8 inch hot swap solid state drives see Supported drive backplane configurations on page 69 for more information You can mix 2 5 inch hot swap SAS and SATA hard disk drives 2 5 inch hot swap solid state drive and 1 8 inch hot swap solid state drives in the same server as long as they are not on the ...

Page 255: ...ot swap drive a Make sure that the drive tray handle is in the open unlocked position b Align the drive assembly with the guide rails in the bay Drive tray assembly Drive handle in open position c Gently push the drive tray assembly into the bay until it is seat firmly in place d Rotate the drive tray handle to the closed locked position e Skip to Step 4 step 4 on page 242 Chapter 6 Removing and r...

Page 256: ...erveRAID adapter you might have to reconfigure your disk arrays after you install drives See the ServeRAID adapter documentation for additional information about RAID operation and complete instructions for using the ServeRAID adapter Step 5 If you are installing additional hot swap drives do so now Removing the 4x2 5 inch hot swap drive backplanes Use this information for instructions on how to r...

Page 257: ...structed to return the drive backplane follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the 4x2 5 inch hot swap drive backplanes Use this information for instructions on how to replace the 4x2 5 inch hot swap drive backplane assembly To install the replacement hot swap 2 5 inch drive backplanes complete the following steps 1 Align th...

Page 258: ...backplane assembly if you have not done so see Replacing 2 5 inch and 1 8 inch hot swap drives on page 240 5 Reinstall the filler panels 6 Reinstall the storage book into the server 7 Reconnect the power cords and any cables that you removed 8 Turn on the peripheral devices and the server 244 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 259: ...5 Remove the drives from the drive backplane assembly see Removing 2 5 inch and 1 8 inch hot swap drives on page 238 and install them in the new backplane assembly Step 6 Disconnect the cables from the drive backplane Step 7 Press the release latch to the left on the drive backplane assembly while pushing on the rear of the drive backplane and slide the drive backplane assembly out of the storage ...

Page 260: ... Reconnect the power cords and any cables that you removed Step 8 Turn on the peripheral devices and the server Removing a memory module This topic provides instructions about how to remove a memory module To remove a dual inline memory module DIMM complete the following steps Note You can press the light path button on the compute book to light the LEDs on the board when the compute book has been...

Page 261: ... Step 6 If you are instructed to return the DIMM follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing a memory module This topic provides instructions about how to replace a memory module Notes See Installing a memory module on page 46 for notes and information that you must consider when you install DIMMs For DIMM population information...

Page 262: ...IMM 13 DIMM 18 DIMM 17 DIMM 16 To install a DIMM complete the following steps Step 1 Touch the static protective package that contains the DIMM to any unpainted metal surface on the outside of the server Then remove the DIMM from the package Step 2 Open the retaining clip on each end of the DIMM connector Attention To avoid breaking the retaining clips or damaging the DIMM connectors open and clos...

Page 263: ...ok Step 7 Reinstall the compute book in the server see Replacing a compute book on page 292 Step 8 Reconnect the power cord and any cables that you removed Step 9 Turn on the peripheral devices and the server Removing the ServeRAID M5120 SAS SATA Controller for System x User this information for instructions on how to remove the ServeRAID M5120 SAS SATA Controller To remove a ServeRAID M5120 SAS S...

Page 264: ...rs on page 86 for more information For configuration information see the ServeRAID documentation at http datacentersupport lenovo com Attention Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code To install a ServeRAID M5120 S...

Page 265: ...d to you Replacing the N2215 SAS SATA Host Bus Adapter for System x User this information for instructions on how to replace the N2215 SAS SATA Host Bus Adapter Note For additional information and notes about installing adapters see Installing an adapter on page 83 You can purchase the optional N2215 SAS SATA Host Bus Adapter for System x This solid state driver controller provides no RAID support...

Page 266: ...ines on page 44 Step 2 Turn off the server see Turning off the server on page 40 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the standard I O book from the server see Removing the standard I O book on page 224 Step 4 Locate the USB embedded hypervisor flash device connector on the standard I O b...

Page 267: ...ffle Standard I O book Step 6 If you are instructed to return the USB flash device follow all packaging instructions and use any packaging materials for shipping that are supplied to you Chapter 6 Removing and replacing components 253 ...

Page 268: ...th the connector on the standard I O book board and push it into the connector until it is firmly seated Step 2 Slide the lockbar up to the locked position until the lockbar is firmly seated Rotate the air baffle down if rotated it up earlier Lockbar USB Hypervisor key Air baffle Standard I O book Step 3 Reinstall the standard I O book in the server see Replacing the standard I O book on page 227 ...

Page 269: ...nnected from the power source 1 2 Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician To remove a hot ...

Page 270: ...structed to return the power supply follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing a 1400 watt or 900 watt hot swap power supply Use this information for instructions on how to replace a 1400 watt or 900 watt hot swap power supply Note This information and instructions apply to both the 4 socket and the 8 socket servers The followi...

Page 271: ... configurations apply for each 4 socket node of the 8 socket server Table 56 Supported ac power supply configurations at both 220 V ac and 110 V ac for each 4 socket node Number of power supplies Power supply wattage One 900 watt One 1400 watt Two 900 watt Two 1400 watt Four Two 900 watt and two 1400 watt Four 900 watt Four 1400 watt Statement 5 CAUTION The power control button on the device and t...

Page 272: ...d metal surface on the server then remove the power supply from the package and place it on a static protective surface 3 If you are installing a hot swap power supply into an empty bay remove the power supply filler panel from the power supply bay 4 Replacing a 1400 watt hot swap power supply a Grasp the handle on the rear of the power supply and slide the power supply forward into the power supp...

Page 273: ... power supply 8 Connect the other end of the power cord to a properly grounded electrical outlet 9 Turn on the peripheral devices and the server 10 Make sure that the ac power LED and the dc power LED on the power supply are lit indicating that the power supply is being supplied to the power supply through the power cord During normal operation both ac and dc power LEDs are lit For other combinati...

Page 274: ...otal of 20 fans Notes The fan packs on the compute books and the Standard I O book are not interchangeable The fan packs have text printed on the front of the fan above the fan handle that indicates which book the fan pack should be installed in For example the fan pack for a compute books might have the text Top Compute Book Only The fan pack for a Standard I O book might have the text Top Standa...

Page 275: ...eplace a hot swap fan pack complete the following steps Note These procedures for replacing a hot swap fan assembly apply to both the standard I O book and the compute books 1 Make sure that you are installing the appropriate fan pack for the I O book Note The fan packs have text printed on the front of the fan above the fan handle that indicates which book the fan pack should be installed in For ...

Page 276: ...O book board Step 6 If you are instructed to return the adapter follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing an ML2 Ethernet adapter Use this information for instructions on how to remove an ML2 Ethernet adapter The following are illustrations of the ML2 Ethernet adapters that the server supports See Supported ML2 Ethernet adapte...

Page 277: ...ion of the Intel x540 ML2 Dual port 10 Gb T Ethernet Adapter for System x Intel x540 ML2 Dual port 10 Gb T Ethernet adapter Link LED Activity LED Link LED Activity LED Port 1 Port 2 The following is an illustration of the Emulex VFA5 ML2 Dual port 10 Gb SFP Ethernet Adapter for System x Chapter 6 Removing and replacing components 263 ...

Page 278: ...NetXtreme II ML2 Dual port 10 Gb T Ethernet adapter for System x Broadcom NetXtremeII ML2 Dual port 10 Gb T Ethernet adapter Link LED Activity LED Link LED Activity LED Port 1 Port 2 The following is an illustration of the Broadcom NetXtreme II ML2 Dual port 10 Gb SFP Ethernet adapter for System x 264 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 279: ...ly seated adapter might cause damage to the standard I O book board or the adapter Step 4 Close the adapter retention lever Step 5 Reinstall the standard I O book in the server see Replacing the standard I O book on page 227 Step 6 Perform any configuration tasks that are required for the adapter Step 7 Reconnect the power cord and any cables that you removed Step 8 Turn on the peripheral devices ...

Page 280: ... the adapter and remove the flash power module from the slot on the air baffle Air baffle Standard I O book If you are instructed to return the flash power module follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing a RAID adapter flash power module in the standard I O book Use this information for instructions on how to replace a RAID a...

Page 281: ...the flash power modules in the two slots on the left side facing the front of the standard I O book of the air baffle route the cables through the clips and the holes on the side of the air baffle as shown in the following illustration When you install a flash power module in the slot on the right side of the air baffle route the cable through the hole under the flash power module slot Step 3 Conn...

Page 282: ...this information for instructions on how to replace a RAID cache card Notes For additional information and notes about installing adapters see Installing an adapter on page 83 For information about the support RAID adapters and cache cards see Supported RAID adapters on page 86 and Supported RAID cache cards on page 87 To replace an RAID cache card complete the following steps Step 1 Align the new...

Page 283: ... replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not Throw or immerse into water Heat to more than 100 C 212 F Repair or disassemble Dispose of the battery as required by local ordinances or regulations To remove the system battery that is on the standard I O book board complete the ...

Page 284: ...ery recommended by the manufacturer If your system has a module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not Throw or immerse into water Heat to more than 100 C 212 F Repair or disassemble Dispose of the battery as required by local ordinances or r...

Page 285: ...er before the power on button becomes active Step 5 Start the Setup utility and reset the configuration 1 Set the system date and time 2 Set the power on password 3 Reconfigure the server See Using the Setup utility on page 123 for details Chapter 6 Removing and replacing components 271 ...

Page 286: ...k and place two fingers in the finger holes and carefully slide the front I O panel forward toward the front of the storage bookand remove it Front I O panel Storage book Finger holes Release latch Step 6 If you are instructed to return the front I O panel assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the front I O panel ...

Page 287: ... to install it at no additional charge under the type of warranty service that is designated for your server The illustrations in this document might differ slightly from your hardware Removing the storage book Use this information for instructions on how to remove the storage book To remove the storage book complete the following steps 1 Before you begin read Safety on page v and Installation gui...

Page 288: ...mbly on page 272 13 If you are instructed to return the assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the storage book Use this information for instructions on how to replace the storage book Notes For additional information see Storage book on page 24 The PCIe slots on this storage book only support storage host bus adap...

Page 289: ...o the server Place one hand under the center of the storage book to support it while sliding it into the server Storage book 9 Rotate the cam handle all the way up and push it into the server until it locks in place 10 Reinstall the drives in the front of the storage book 11 Reconnect the power cord and any cables that you removed 12 Turn on the peripheral devices and the server Removing the stora...

Page 290: ...oard assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the storage book board assembly Use this information for instructions on how to replace the storage book board assembly To replace the storage book board assembly complete the following steps 1 Align the new storage book board assembly with the slots on the side of storag...

Page 291: ...mplete the following steps Step 1 Before you begin read Safety on page v and Installation guidelines on page 44 Step 2 Turn off the server see Turning off the server on page 40 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the storage book from the server see Removing the storage book on page 273 ...

Page 292: ...ng materials for shipping that are supplied to you Replacing the front operator panel assembly Use this information for instructions on how to replace the front operator panel To install the front operator panel complete the following steps Step 1 Record take a photograph of the barcode label or write down the barcode number the 11S and FRU barcode information for the existing and replacement fron...

Page 293: ...t the LCD display panel cable to the LCD display panel Step 6 Align the front operator panel with the slot on the storage book and slide it in until it is seated in place Step 7 Reconnect the front operator panel cables to the storage book board and the rear air baffle Make sure that you reinstall the plug that your removed from the old assembly to the rear of the new air baffle Step 8 Reinstall t...

Page 294: ...barcode In the following example the FRU part number is shown in bold FRU 12X4567 d Update FRU part number VPD Use the following ASU command to update the FRU part number VPD asu64 set VPD CompVPD_FRUNumber 3 fru_number sp sp sp sp sp where fru_number is the 7 character FRU part number above followed by five padding spaces Step 12 Restart the IMM2 then restart the server Removing the LCD system in...

Page 295: ... Step 7 Grasp the tab on the LCD retention latch and pull it to the right to disengage the latch and remove the LCD display panel Step 8 If you are instructed to return the device follow all packaging instructions and use any packaging materials for shipping that are supplied to you Chapter 6 Removing and replacing components 281 ...

Page 296: ...board installed on the back of the LCD system information display panel This information is required to update the customer records service offering support information and component VPD Step 2 Orient the LCD system information display panel so that the LCD connect is next to the LEDs on the operator panel Step 3 Lower the LCD system information display panel while aligning the LCD retention latch...

Page 297: ...rmation The component part number is the first seven characters following the 11S of the 11S barcode In the following example the component part number is shown in bold 11S12X4567YJ1105A34567 b Update component part number VPD Use the following ASU command to update the component VPD asu64 set VPD CompVPD_PartNumber 4 p n sp sp sp sp sp where p n is the 7 character component part number followed b...

Page 298: ...mber 4 fru_number sp sp sp sp sp where fru_number is the 7 character FRU part number above followed by five padding spaces Step 11 Restart the IMM2 then restart the server Removing and replacing FRUs This topic provides information about removing and replacing FRUs FRUs must be replaced or installed only by trained service technicians The illustrations in this document might differ slightly from t...

Page 299: ...e Step 3 Remove the compute book from the server Step 4 Remove the compute book cover see Removing the compute book cover on page 222 Step 5 Remove the heat sinks a Use a screwdriver to loosen the captive screw on one side of the heat sink to break the seal with the microprocessor b Loosen all the captive screws on the heat sink rotating each screw one full turn until each screw is loose Heatsink ...

Page 300: ...r from the socket a Use the empty installation tool and ensure that the handle is in the open position If the tool handle is not in the open position twist the handle on the microprocessor installation tool counterclockwise so that it is in the open position b Align the holes on the installation tool with the screws on the microprocessor bracket then lower the microprocessor installation tool down...

Page 301: ...acts are very fragile Do not allow the thermal grease on the microprocessor and heat sink to come in contact with anything Contact with any surface can compromise the thermal grease and the microprocessor socket Do not touch the microprocessor contacts Contaminants on the microprocessor contacts such as oil from your skin can cause connection failures between the contacts and the socket Be sure to...

Page 302: ...y Dropping the microprocessor during installation or removal can damage the contacts Do not use excessive force when you press the microprocessor into the socket Make sure that the microprocessor is oriented and aligned and positioned in the socket before you try to close the lever d Release the sides of the microprocessor protective cover on the bottom of the microprocessor and carefully remove t...

Page 303: ... Notes Do not press the microprocessor into the socket Do not touch the thermal grease on the bottom of the heat sink or on top of the microprocessor Touching the thermal grease will contaminate it Make sure that the microprocessor is oriented and aligned correctly in the socket before you close the microprocessor bracket frame g Lift the microprocessor installation tool from the socket h Remove t...

Page 304: ...ocessor The heat sink is keyed to assist with proper alignment b Align the screws on the heat sink with the holes on the heat sink retention module Heatsink c Press firmly on the center of the heat sink then press firmly on the captive screws and tighten them with a screwdriver alternating between the screws in a figure 8 pattern as indicated on the heat sink label Rotate each screw one full rotat...

Page 305: ...e the cleaning pad from its package and unfold it completely 3 Use the cleaning pad to wipe the thermal grease from the bottom of the heat sink Note Make sure that all of the thermal grease is removed 4 Use a clean area of the cleaning pad to wipe the thermal grease from the microprocessor then dispose of the cleaning pad after all of the thermal grease is removed Microprocessor 0 02 mL of thermal...

Page 306: ...see Removing a microprocessor and heat sink on page 284 Step 7 Remove the DIMMs see Removing a memory module on page 246 Step 8 Remove the fans see Removing a hot swap fan assembly on page 259 If you are instructed to return the compute book follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing a compute book This information provides ins...

Page 307: ...ompute book 3 4 compute book 4 The 8 socket x3950 X6 server supports compute book configurations of four six or eight These are the only configurations supported The following tables list the installation sequence for the supported compute book configurations Table 60 Installation sequence for the four compute books configuration for an 8 socket server Compute book Top node bay 1 Top node bay 2 To...

Page 308: ...k on page 29 For more information about installing DIMMs see Installing a memory module on page 46 For a list of supported devices see http www lenovo com serverproven To install the compute book complete the following steps Step 1 Reinstall the microprocessor and heat sink on the new compute book see Replacing a microprocessor and heat sink on page 287 Step 2 Reinstall the DIMMs see Replacing a m...

Page 309: ...ve a 750 watt 48 volt to 60 volt dc power supply When you remove a 750 watt 48 V to 60 V dc power supply observe the following precautions Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these ...

Page 310: ...uct When possible use one hand only to connect or disconnect signal cables Never turn on any equipment when there is evidence of fire water or structural damage Disconnect the attached ac power cords dc power sources network connections telecommunications systems and serial cables before you open the device covers unless you are instructed otherwise in the installation and configuration procedures...

Page 311: ...lt dc power supply The following notes provide information that you must consider when you install a 750 watt 48 V to 60 V dc power supply To confirm that the server supports the power supply that you are installing see http www lenovo com serverproven Attention This information apply to both the 4 socket and 8 socket servers Only trained service technicians other than Lenovo service technicians a...

Page 312: ...lowing label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Statement 19 CAUTION The power control button on the device does not turn off the electrical current supplied to the device The device also...

Page 313: ...arth ground should use a two hole lug for safety 4 Attach signal cables to other devices 5 Connect power cords to their sources 6 Turn ON all the power sources Do not connect or disconnect any cables or perform installation maintenance or reconfiguration of this product during an electrical storm Connect all power cords to a properly wired and grounded power source Connect to properly wired power ...

Page 314: ...on for the required wire size See the specifications in the product documentation for the required torque values for the wiring terminal screws To install a 750 watt 48 V to 60 V dc power supply complete the following steps 1 Touch the static protective package that contains the power supply to any unpainted metal surface on the server then remove the power supply from the package and place it on ...

Page 315: ...cks Make sure that the power supply connects firmly into the power supply connector 7 Route the power cord through the hook and loop strap so that it does not accidentally become disconnected 8 Turn on the circuit breaker s for the dc power supplies 9 Reconnect any external cables that you disconnected 10 Turn on the server and the peripheral devices 11 Make sure that the server starts correctly a...

Page 316: ...ightly Step 4 Remove all of the components from the rear of the server Step 5 Optional Install the lower shipping bracket that comes with the System x3850 X6 and x3950 X6 Rack Installation Kit or with the replacement midplane to help support the shuttle while removing and replacing the midplane See the Lenovo System x3850 X6 and x3950 X6 Type 6241 Rack Installation Instructions for instructions No...

Page 317: ...To replace the chassis midplane complete the following steps Note This procedure for replacing the midplane apply to both the 4 socket and the 8 socket configurations of the server unless otherwise specified Step 1 Record take a photograph of the barcode label or write down the barcode number the 11S and FRU barcode information for the existing and replacement 4 socket or 8 socket midplane The lab...

Page 318: ...they lock in place on the chassis Step 5 Reinstall all of the components in the rear of the server Step 6 Slide the components in the front of the server back into the server Step 7 Reconnect the power cords and any cables that you removed Step 8 Turn on the peripheral devices and the server Step 9 Update the midplane part number FRU part number serial number and prefix serial number in the custom...

Page 319: ...refix serial number is the six characters of the 11S barcode that follow the first 10 characters of the 11S barcode the six characters preceding the component serial number portion of the 11S barcode In the following example the prefix serial number is shown in bold 11S12X4567YJ1105A34567 d Update component serial number and prefix serial number VPD Use the following ASU command to update the comp...

Page 320: ...s Disconnect all power cords then disconnect all external cables from the server Step 3 Slide all of the components in the front of the server out slightly Step 4 Remove all of the components from the rear of the server Step 5 Remove the shuttle For the 4U server configuration do the following 1 Press the blue buttons on the interior wall of the shuttle to release the shuttle cam handles and rotat...

Page 321: ...interior wall of the top node shuttle to release the shuttle cam handles and rotate the handles all the way down 3 Now rotate the cam handles on the bottom node shuttle all the way down Chapter 6 Removing and replacing components 307 ...

Page 322: ...s Step 6 Lift the midplane all the way up off the alignment pins on the shuttle and remove it from the shuttle Midplane assembly Alignment pins Alignment pins Shuttle If you are instructed to return the shuttle follow all packaging instructions and use any packaging materials for shipping that are supplied to you 308 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 323: ...the midplane onto the pins until the midplane is seated in place on the shuttle Midplane assembly Alignment pins Alignment pins Shuttle Step 2 Make sure that the cam handles are open Grasp the shuttle with your hand through the hole on the center of the shuttle and grasp the bottom of the shuttle with your other hand and align it with the shuttle slot then slide the shuttle into the chassis until ...

Page 324: ...vements from Lenovo Attention Installation of the ITL kit must be performed by a Lenovo approved service technician Upgrade task summary Several processes need to be completed to perform an IBM to Lenovo server upgrade Some tasks must be completed to prepare for the upgrade in advance of performing the actual upgrade Each task is described in detail by the sub topics following the task summary In ...

Page 325: ...est new FoD keys for use in the Lenovo server a Make a list of all the FoD activation keys that are active for the IBM server Select Retrieve history at the Features on Demand website https www ibm com systems x fod to view the active keys for the IBM server b Verify which FoD are installed in the IBM server see the IBM Integrated Management Module II User s Guide at https www ibm com support entr...

Page 326: ...es with the ITL kit This is required to update the customer entitlement and service offering support Note You will need the server IMM IP address user name and password to perform the following step If you are upgrading a x3950 server you will need the IP address for both IMMs 5 Using the IBM Advanced Settings Utility ASU tool backup export the system configuration Features on Demand FoD keys and ...

Page 327: ...how SYSTEM_PROD_DATA host IMM IP user IMM userid password IMM password serial _system txt where IMM IP is the IMM IP address IMM userid is the IMM user name IMM password is the IMM password serial is the serial number of the standard I O book allows each data file to be identified b To save the system component VPD information into a file run the ASU command asu64 show VPD host IMM IP user IMM use...

Page 328: ...IMM password is the IMM password serial is the serial number of the standard I O book allows each data file to be identified b To save the system component VPD information for node 2 into a file run the ASU command asu64 show VPD host IMM IP user IMM userid password IMM password serial _Node2_component txt where IMM IP is the IMM IP address IMM userid is the IMM user name IMM password is the IMM p...

Page 329: ...ion b Transfer components and devices adapters fans USB embedded hypervisor flash device and flash power modules from the IBM standard I O book originally installed in the server to the new Lenovo standard I O book that comes with the ITL kit see Replacing the standard I O book on page 227 for instructions Important When installing the standard I O book in the system look for missing or broken tab...

Page 330: ...stem see Replacing the standard I O book on page 227 for instructions Notes Make sure that all of the feet mounted on bottom side standard I O book engage the slots in the mechanical assembly 316 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 331: ...age html and the Lenovo Advanced Settings Utility InfoCenter at http toolscenter lenovofiles com help topic asu_lenovo asu_ main html for information about how to use these tools Access the Lenovo ASU tool Access the Lenovo ASU tool by completing the following steps Note For a Lenovo System x3950 X6 8 socket system the following procedure must be performed twice once for each of the standard I O b...

Page 332: ... serial _system bat file where serial is the serial number of the standard I O book allowing each batch file to be identified This file will be edited to create a VPD update batch file 2 Complete the following steps to add commands to the serial _system bat file a Open the serial _system txt file where serial is the serial number of the standard I O book This file was saved from the IBM System x38...

Page 333: ...me serial number that was used for the IBM server g Add a command line to the batch file for the Lenovo server serial number following the form asu64 set SYSTEM_PROD_DATA SysInfoSerialNum serial_number host IMM_IP user IMM_userid password IMM_password where serial_number is a 7 character field for the product serial number the Lenovo server and the IBM server use the same serial number IMM_IP is t...

Page 334: ...t number is shown in bold 11S12X4567YJ1105A34567 k Add a command line to the batch file for each Lenovo server component part number following the form asu64 set VPD CompVPD_PartNumber p n sp sp sp sp sp host IMM_IP user IMM_userid password IMM_password where is the component numeric identifier 1 for the 4 socket midplane 3 for the front I O panel assembly 4 for LCD display panel p n is the first ...

Page 335: ...IBM server component serial numbers in the serial _component txt file There are multiple component serial numbers in the following format VPD CompVPD_SerialNumber s n where is the component numeric identifier 1 for the 4 socket midplane 3 for the front I O panel assembly 4 for LCD display panel Note A serial number for the front I O panel assembly 3 is not required and might not be listed s n is a...

Page 336: ...serial numbers remain unchanged they are the same serial numbers that were used in the IBM server The serial number prefix is the six characters of the 11S barcode that follow the first 10 characters of the 11S barcode the six characters preceding the component serial number portion of the 11S barcode In the following example the serial number prefix is shown in bold 11S12X4567YJ1105A34567 q Add a...

Page 337: ...number c Change the IBM server machine type to the Lenovo server machine type by replacing the IBM server 4 character machine type 3837 with the Lenovo server 4 character machine type 6241 The 3 character model number remains unchanged between the IBM and Lenovo servers For example if the original IBM server machine type and model number was 3837FT4 the new Lenovo server machine type and model num...

Page 338: ...foUUID node1_uuid host IMM_IP user IMM_userid password IMM_password where node1_uuid is a 16 character hexadecimal field for the server node 1 UUID Contact the customer to determine if the original UUID value should be used or if a new UUID value should be generated for the upgraded server If needed locate the original IBM server UUID in the serial _Node1_system txt file This string has the follow...

Page 339: ...and the IBM server use the same component part numbers IMM_IP is the IMM IP address IMM_userid is the IMM user name IMM_password is the IMM password l Locate the IBM server component FRU part numbers in the serial _Node1_ component txt file There are multiple component FRU part numbers in the following format VPD CompVPD_FRUNumber fru_number where is the component numeric identifier 2 for the 8 so...

Page 340: ...rial number Notes The Lenovo server component serial numbers remain unchanged they are the same serial numbers that were used in the IBM server The serial number is the last six characters of the 11S barcode In the following example the serial number is shown in bold 11S12X4567YJ1105A34567 o Add a command line to the batch file for each Lenovo server component serial number following the form asu6...

Page 341: ...dd a command line to the batch file for each Lenovo server component serial number prefix following the form asu64 set VPD CompVPD_PrefixSerialNumber prefix_s n host IMM_IP user IMM_userid password IMM_password where is the component numeric identifier 2 for the 8 socket midplane 3 for the front I O panel assembly 4 for LCD display panel Note A serial number for the front I O panel assembly 3 is n...

Page 342: ...step this model number varies based on the original IBM server model number following the form asu64 set SYSTEM_PROD_DATA SysInfoProdName Lenovo_machine_type_model host IMM_IP user IMM_userid password IMM_password where Lenovo_machine_type_model is a 7 character field that combines the new Lenovo 4 character machine type and the original IBM 3 character model number IMM_IP is the IMM IP address IM...

Page 343: ... is the IMM IP address IMM_userid is the IMM user name IMM_password is the IMM password i Open the serial _Node2_component txt file where serial is the serial number of the standard I O book in node 2 This file was saved from node 2 of the IBM System x3950 X6 8 socket system during the Backup vital product data VPD procedure j Locate the IBM server component part numbers in the serial _Node2_compo...

Page 344: ...nel fru_number is a 7 character FRU part number Note The Lenovo server component FRU part numbers remain unchanged they are the same FRU numbers that were used in the IBM server m Add a command line to the batch file for each Lenovo server component FRU part number following the form asu64 set VPD CompVPD_FRUNumber fru_number sp sp sp sp sp host IMM_IP user IMM_userid password IMM_password where i...

Page 345: ...r IMM_ userid password IMM_password where is the component numeric identifier 2 for the 8 socket midplane 3 for the front I O panel assembly 4 for LCD display panel Note A serial number for the front I O panel assembly 3 is not required s n is a 6 character component serial number the Lenovo server and the IBM server use the same component serial numbers IMM_IP is the IMM IP address IMM_userid is ...

Page 346: ...aracter component serial number prefix the Lenovo server and the IBM server use the same component serial number prefixes IMM_IP is the IMM IP address IMM_userid is the IMM user name IMM_password is the IMM password Note To view an example VPD batch file see IBM to Lenovo server upgrade batch file examples on page 336 3 Save and close the file Restore VPD using the batch files Note For a Lenovo Sy...

Page 347: ...EIA bezel on the server then press it fully into place b Replace the IBM system labels with Lenovo system labels DANGER Be careful when sliding the server forward to attach the new agency label Moving the server too far forward can cause the rack to tip or the server to fall out of the rack 1 Slide the server forward in the rack Chapter 6 Removing and replacing components 333 ...

Page 348: ...Con ne ctor BR D 12 11 LC D Display Pow er Button LE D Res et Button Sys tem Error LE D Sys tem Iden tification Button LE D Che ck Lo g LE D Intern al PCIe Slot 11 Error LE D Intern al PCIe Slot 12 Error LE D Intern al Storage Boa rd Error LE D Lig ht Path Diagnostics Errors Error 1 Error 2 Error 3 Error n Sys tem VPD MTM Serial UUID String pDSA Code Sys tem FW Lev els UEFI Primary Lev el UEFI Bac...

Page 349: ...ure that there are no errors messages see Error messages on page 168 If problems are encountered following the ITL upgrade troubleshoot the system using standard methods see Start here on page 145 If you are unable to resolve the problem open an online service request go to https www ibm com support servicerequest Home action Be prepared to provide information about any error codes and collected d...

Page 350: ...he Lenovo System x3850 X6 4 socket system requires a single VPD batch file An example batch file is shown below rem Lenovo server machine type and model requires a total of 7 characters with no double quotes asu64 set SYSTEM_PROD_DATA SysInfoProdName 6241F4Y host 192 168 70 125 user USERID password PASSW0RD rem Lenovo server product indentifier requires double quotes asu64 set SYSTEM_PROD_DATA Sys...

Page 351: ...ASSW0RD rem Lenovo server UUID requires a total of 16 characters entered in hexadecimal with no double quotes Note 8 Socket Node 1 and Node 2 have different UUID s asu64 set SYSTEM_PROD_DATA SysInfoUUID 5CCEDA3465F436E8ADFA6EAE8B4B77BA host 192 168 70 125 user USERID password PASSW0RD rem Lenovo server component part numbers require double quotes and a total of 12 characters including insertion of...

Page 352: ...d PASSW0RD asu64 set VPD CompVPD_PartNumber 4 78P3448 host 192 168 70 125 user USERID password PASSW0RD rem Lenovo server component FRU part numbers require double quotes and a total of 12 characters including insertion of 5 blanks asu64 set VPD CompVPD_FRUNumber 1 00FN638 host 192 168 70 125 user USERID password PASSW0RD asu64 set VPD CompVPD_FRUNumber 3 00FG825 host 192 168 70 125 user USERID pa...

Page 353: ... system timeout if no activity Action SYS OFF BLK PWR The system is off no power permissions granted by IMM Normal No action is required SYSTEM OFF The system is off Normal No action is required UEFI AUTH USER Authenticating the user Normal No action is required UEFI F1 SETUP Waiting at F1 menu Normal No action is required UEFI BOOT DIAGS The system is booting to pDSA Normal No action is required ...

Page 354: ...Flash the UEFI primary bank UEFI SIG CHK BK Verifying the signature of the backup bank After 2 minutes Flash the UEFI backup bank UEFI UPDATE PRI UEFI is updating the primary bank After 2 minutes 1 Restart the server 2 Flash the UEFI firmware 3 Clear CMOS UEFI UPDATE BKP UEFI is updating the backup bank After 2 minutes 1 Restart the server 2 Flash the UEFI firmware 3 Clear CMOS UEFI END SEC UEFI i...

Page 355: ...on is running After 2 minutes 1 Restart the server 2 Flash the UEFI firmware 3 Clear CMOS UEFI SMBIOS RDY The SMBIOS tables are ready to be sent to IMM After 2 minutes 1 Restart the server 2 Flash the UEFI firmware 3 Clear CMOS UEFI SMI INS UEFI is running After 2 minutes 1 Restart the server 2 Flash the UEFI firmware 3 Clear CMOS UEFI BOOTLEG Booting legacy After 2 minutes Make sure that the boot...

Page 356: ...vity or 10 IMM reboot cycles 1 Disconnect the power from the server 2 Reset IMM see Setup utility menu choices on page 123 3 Replace the standard I O book IMM NETWORK IMM is loading the kernel After 15 minutes of no activity or 10 IMM reboot cycles 1 Disconnect the power from the server 2 Perform a web or inband flash of the IMM firmware using TFTP burn IMM BOOTING IMM is loading the kernel After ...

Page 357: ...flash of the IMM firmware using TFTP burn IMM FLASH MNGR IMM is loading the kernel After 15 minutes of no activity or 10 IMM reboot cycles 1 Disconnect the power from the server 2 Perform a web or inband flash of the IMM firmware using TFTP burn IMM UEFI SYNC IMM is loading the kernel After 15 minutes of no activity or 10 IMM reboot cycles 1 Disconnect the power from the server 2 Perform a web or ...

Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 359: ...the DSA Broadcom network test 405 000 000 BRCM TestControlRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 405 001 000 BRCM TestMIIRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support we...

Page 360: ...inks Lenovo Support website Latest level of DSA 405 004 000 BRCM TestInterrupt Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 405 005 000 BRCM TestLoopbackMAC Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links 346 Sys...

Page 361: ... Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 405 800 000 BRCM TestControlRegisters Test Aborted The control registers test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 405 801 000 BRCM TestMIIRegisters Test...

Page 362: ... No Related links Lenovo Support website Latest level of DSA 405 803 000 BRCM TestInternalMemory Test Aborted The internal memory test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 405 804 000 BRCM TestInterrupt Test Aborted The interrupt test was canceled Recoverable No Severity Warning Servicea...

Page 363: ...vel of DSA 405 806 000 BRCM TestLoopbackPhysical Test Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 405 807 000 BRCM TestLEDs Test Aborted Verification of status LEDs was canceled Recoverable No Severity Warning Serviceable No Automatically notify su...

Page 364: ...est level of DSA 405 901 000 BRCM TestMIIRegisters Test Failed A failure was detected while testing internal PHY registers Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD ...

Page 365: ... A failure was detected while testing internal memory Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refe...

Page 366: ...ceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next...

Page 367: ... Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website ...

Page 368: ...rdesLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 218 003 000 Brocade PCILoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 218 004 000 Brocade ExternalEthLo...

Page 369: ...ty Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 218 006 000 Brocade InternalLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 218 800 000 Brocade MemoryTest Aborted The test was canceled Recoverable No Severity Appe...

Page 370: ...ated links Lenovo Support website Latest level of DSA 218 802 000 Brocade SerdesLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 218 803 000 Brocade PCILoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support...

Page 371: ... Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 218 806 000 Brocade InternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 218 900 000 Brocade Memory...

Page 372: ...ure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at proper level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links Lenovo Support website Latest level of ...

Page 373: ... Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Rerun the test 2 Verify whether the firmware is at proper level 3 Rerun the test 4 If the problem remains contact your IBM technical support representative Related links Lenovo Support website Latest level of DSA 218 904 000 Brocade ExternalEthLoopbackTest Faile...

Page 374: ...fy support No User Response Complete the following steps 1 Rerun the test 2 Verify whether the firmware is at proper level 3 Rerun the test 4 If the problem remains contact your IBM technical support representative Related links Lenovo Support website Latest level of DSA 218 906 000 Brocade InternalLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Se...

Page 375: ...pport No Related links Lenovo Support website Latest level of DSA 180 801 000 Check point Panel Test Aborted Check point Panel Test Aborted BMC is unable to verify that the operator information panel cable is connected Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Inspect and reseat operator information panel cable at b...

Page 376: ... assembly 5 Run the test again 6 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA DSA CPU stress test results The following messages are generated when you run the CPU stress test Test results for the DSA CPU stress test The following messages can result when y...

Page 377: ...If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA 089 802 000 CPU Stress Test Aborted CPU Stress Test Aborted System resource unavailability error Recoverable No S...

Page 378: ...un the test At least 1GB is required Recoverable No Severity Warning Serviceable Yes Automatically notify support No Related links Lenovo Support website Latest level of DSA 089 804 000 CPU Stress Test Aborted CPU Stress Test Aborted User pressed Ctrl C Recoverable No Severity Warning Serviceable Yes Automatically notify support No Related links Lenovo Support website Latest level of DSA 089 901 0...

Page 379: ...ting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA DSA Emulex adapter test results The following messages are generated when you run the Emulex adapter test Test results for the DSA Emulex adapter test The following messages can result when you run the DSA Emulex adapter test 516 000 000 ELXUCNA NIC M...

Page 380: ...was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 516 801 000 ELXUCNA NIC PHY LoopBackTest Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 516 802 000 EL...

Page 381: ...cessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA 516 901 000 ELXUCNA NIC PHY LoopBackTest Failed A failure wa...

Page 382: ...wing steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA...

Page 383: ...technical service representative Related links Lenovo Support website Latest level of DSA 401 802 000 EXA Port Ping Test Aborted EXA Port Ping Test Aborted Port connections may not be correct Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure th...

Page 384: ...ur technical service representative Related links Lenovo Support website Latest level of DSA DSA hard drive test results The following messages are generated when you run the hard drive test Test results for the DSA hard drive test The following messages can result when you run the DSA hard drive test 217 000 000 HDD Test Passed HDD Stress Test Passed Recoverable No Severity Event Serviceable No A...

Page 385: ...No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify the firmware is at the latest level 4 Rerun the test 5 If the problem remains contact your technical support representative Related links Lenovo Support website Latest level of DSA DSA Intel network test results The following messages are ...

Page 386: ... Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 406 002 000 IANet FIFO Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 406 003 000 IANet Interrupts Test Passed The test passed Recoverable No Severity 372 System x3850 X6 and x3950...

Page 387: ...elated links Lenovo Support website Latest level of DSA 406 800 000 IANet Registers Test Aborted Registers test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 406 801 000 IANet EEPROM Test Aborted EEPROM test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support ...

Page 388: ...st was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 406 804 000 IANet Loopback Test Aborted Loopback test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 406 900 000 IANet Registers Test Failed A fai...

Page 389: ...t EEPROM Test Failed A failure was detected during the EEPROM test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure...

Page 390: ...esponse Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log If the ethernet device is sharing interrupts if possible modify the interrupt a...

Page 391: ...ective action Related links Lenovo Support website Latest level of DSA DSA LSI hard drive test results The following messages are generated when you run the LSI hard drive test Test results for the DSA LSI hard drive test The following messages can result when you run the DSA LSI hard drive test 407 000 000 LSIESG DiskDefaultDiagnostic Test Passed The test passed Recoverable No Severity Event Serv...

Page 392: ...em remains contact your IBM technical support representative Related links Lenovo Support website Latest level of DSA DSA Mellanox adapter test results The following messages are generated when you run the Mellanox adapter test Test results for the DSA Mellanox adapter test The following messages can result when you run the DSA Mellanox adapter test 408 000 000 MLNX MLNX_DiagnosticTestEthernetPort...

Page 393: ... was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 408 801 000 MLNX MLNX_DiagnosticTestIBPort Test Aborted Port Test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 408 900 000 MLNX MLNX_DiagnosticTes...

Page 394: ... following steps 1 Make sure that the physical link of the port under test in the active state and a subnet manager running on the fabric to which the port is attached 2 If these condition was met but the test keeps failing the port s adapter might be faulty 3 Try replacing the adapter and repeating the test Related links Lenovo Support website Latest level of DSA DSA memory isolation test results...

Page 395: ...rt No Related links Lenovo Support website Latest level of DSA 201 000 002 Standalone Memory Test Passed Quick Full Memory Test CPU 2 Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 201 000 003 Standalone Memory Test Passed Quick Full Memory Test CPU 3 Passed Recoverable No Severity Event Serviceable No Au...

Page 396: ...fy support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Supp...

Page 397: ...e SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4...

Page 398: ...ollowing steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 812 00...

Page 399: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 812 003 Standalone Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Comple...

Page 400: ...novo Support website Latest level of DSA 201 813 001 Standalone Memory Test Aborted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service...

Page 401: ...borted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 4...

Page 402: ...ature for CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Mak...

Page 403: ...plete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA...

Page 404: ... and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 815 002 Standalone Memory Test Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete...

Page 405: ...ated links Lenovo Support website Latest level of DSA 201 816 000 Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical...

Page 406: ...Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Re...

Page 407: ... Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Page 408: ...ollowing steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 818 00...

Page 409: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 819 001 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No...

Page 410: ...links Lenovo Support website Latest level of DSA 201 819 003 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your t...

Page 411: ...e Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45...

Page 412: ...coverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA ...

Page 413: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Page 414: ... 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 822 000 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete th...

Page 415: ...st level Related links Lenovo Support website Latest level of DSA 201 822 002 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service rep...

Page 416: ...p and disable Node Interleave option and then re run the test Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 s...

Page 417: ...disable Node Interleave option and then re run the test Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Page 418: ...ry Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Mak...

Page 419: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Page 420: ... and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 827 001 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Serviceable No Automatically notify suppo...

Page 421: ...Lenovo Support website Latest level of DSA 201 827 003 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains cont...

Page 422: ... in masking MSR machine check control MASK registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Re...

Page 423: ...heck control MASK registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it ...

Page 424: ...ollowing steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 845 00...

Page 425: ...resentative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 859 000 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complet...

Page 426: ...l Related links Lenovo Support website Latest level of DSA 201 859 002 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 ...

Page 427: ...201 860 000 Standalone Memory Test Aborted No OEM0 type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45...

Page 428: ... type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Mak...

Page 429: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Page 430: ... and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 861 003 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform th...

Page 431: ...test level Related links Lenovo Support website Latest level of DSA 201 862 001 Standalone Memory Test Aborted No OEM1 structure found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service repres...

Page 432: ...one Memory Test Aborted No OEM1 structure found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat ...

Page 433: ...R key in OEM1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Page 434: ...the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 8...

Page 435: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 864 002 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps...

Page 436: ...nks Lenovo Support website Latest level of DSA 201 865 000 Standalone Memory Test Aborted No XSECSRAT key in OEM0 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 ...

Page 437: ...tandalone Memory Test Aborted No XSECSRAT key in OEM0 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45...

Page 438: ...yMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Mak...

Page 439: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Page 440: ... and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 867 001 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Pe...

Page 441: ...lated links Lenovo Support website Latest level of DSA 201 867 003 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative...

Page 442: ...d EFI SAL Buffer allocated in GetMemoryMap too small Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Re...

Page 443: ...GetMemoryMap too small Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to po...

Page 444: ...ollowing steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 869 00...

Page 445: ...e 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 870 000 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete t...

Page 446: ...lated links Lenovo Support website Latest level of DSA 201 870 002 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative...

Page 447: ...000 Standalone Memory Test Aborted Data Mis compare encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45...

Page 448: ...e encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Mak...

Page 449: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Page 450: ... and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 877 003 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No Automatically notify support No...

Page 451: ...ovo Support website Latest level of DSA 201 878 001 Standalone Memory Test Aborted Sparing feature must be turned OFF Go to setup and turn the sparing feature OFF Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact y...

Page 452: ...F Go to setup and turn the sparing feature OFF Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat D...

Page 453: ...to memory without cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Page 454: ...r Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Lates...

Page 455: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 886 002 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete ...

Page 456: ...system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA 201 899 000 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support w...

Page 457: ...tandalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 201 901 000 Standalone Memory Test Failed Memory Diagnostics Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps ...

Page 458: ...ally notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level 5 Replace any DI...

Page 459: ...st Failed Memory Diagnostics Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s R...

Page 460: ...off and restart the system 2 Make sure that the DSA Diagnostic code is at the latest level 3 Run the test again 4 If the system has stopped responding turn off and restart the system 5 Check the system firmware level and upgrade if necessary 6 Run the memory diagnostic to identify the specific failing DIMM 7 If the failure remains refer to Troubleshooting by symptom in the system Installation and ...

Page 461: ...ally notify support No User Response Complete the following steps 1 Execute the standard DSA memory diagnostics to validate all memory 2 Make sure that the DSA Diagnostic code is at the latest level 3 Turn off the system and disconnect it from power 4 Reseat the memory cards and DIMMs 5 Reconnect the system to power and turn the system on 6 Run the test again 7 Execute the standard DSA memory diag...

Page 462: ...tic code is at the latest level 4 Run the test again 5 Execute the standard DSA memory diagnostics to validate all memory 6 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA DSA Nvidia GPU test results The following messages are generated when you run the Nv...

Page 463: ...Test Passed Nvidia GPU Query test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 409 005 000 Nvidia DiagnosticServiceProvider Matrix Test Passed Nvidia GPU Matrix test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of D...

Page 464: ...lated links Lenovo Support website Latest level of DSA 409 803 000 Nvidia DiagnosticServiceProvider Bandwidth Test Aborted Nvidia GPU Bandwidth test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 409 804 000 Nvidia DiagnosticServiceProvider Query Test Aborted Nvidia GPU Query test was canceled Rec...

Page 465: ...e Latest level of DSA 409 806 000 Nvidia DiagnosticServiceProvider Binomial Test Aborted Nvidia GPU Binomial test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 409 900 000 NVIDIA User Diagnostic Test Failed NVIDIA User Diagnostic Test Failed Recoverable No Severity Event Serviceable Yes Automatic...

Page 466: ...tomatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the system 2 Verify that the power connectors to the GPU are connected firmly Then power cycle the system 3 Run nvidia smi q In some cases this will report a poorly connected power cable 4 Rerun the diagnostics using the same GPU ...

Page 467: ...es Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the system 2 Verify that the power connectors to the GPU are connected firmly Then power cycle the system 3 Run nvidia smi q In some cases this will report a poorly connected power cable 4 Rerun the diagnostics using the same...

Page 468: ...cal drive test results The following messages are generated when you run the optical drive test Test results for the DSA optical drive test The following messages can result when you run the DSA optical drive test 215 000 000 Optical Drive Test Passed Optical Drive Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest l...

Page 469: ...ly notify support No User Response Complete the following steps 1 Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized Rerun the test 2 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system I...

Page 470: ... be recognized Rerun the test 3 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 4 Run the test again 5 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA 215 901 000 Optical Drive ...

Page 471: ...e and wait for 15 seconds for the media to be recognized Rerun the test 2 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Late...

Page 472: ...following messages are generated when you run the system management test Test results for the DSA system management test The following messages can result when you run the DSA system management test 166 000 001 IMM I2C Test Passed IMM I2C Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA 166 801 001 IMM...

Page 473: ...Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA 166 803 001 IMM I2C Test Aborted Node Busy Try later Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45...

Page 474: ...actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA 166 806 001 IMM I2C Test Aborted Timeout while processing command Recoverable No Severity Warning Serviceable Yes Automaticall...

Page 475: ...novo Support website Latest level of DSA 166 808 001 IMM I2C Test Aborted Reservation Canceled or Invalid Reservation ID Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure t...

Page 476: ... test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA 166 811 001 IMM I2C Test Aborted Request data field length limit exceeded Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response P...

Page 477: ...001 IMM I2C Test Aborted Cannot return number of requested data bytes Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related...

Page 478: ...ect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA 166 816 001 IMM I2C Test Aborted Command illegal for specified sensor or record type Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and...

Page 479: ...Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA 166 819 001 IMM I2C Test Aborted Command res...

Page 480: ... Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA 166 821 001 IMM I2C Test Aborted Command response could not be provided BMC initialization in progress Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after...

Page 481: ...t No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA 166 824 001 IMM I2C Test Aborted Cannot execute command Recoverable No Severity Warning Service...

Page 482: ...the next corrective action Related links Lenovo Support website Latest level of DSA 166 902 001 IMM I2C Test Failed IMM Indicates failure in TPM BUS 1 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconne...

Page 483: ...st level of DSA 166 905 001 IMM I2C Test Failed IMM Indicates failure in the 9545A bus BUS 4 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the...

Page 484: ...corrective action Related links Lenovo Support website Latest level of DSA DSA tape drive test results The following messages are generated when you run the tape drive test Test results for the DSA tape drive test The following messages can result when you run the DSA tape drive test 264 000 000 Tape Test Passed Tape Test Passed Recoverable No Severity Event Serviceable No Automatically notify sup...

Page 485: ...ape Test Failed Tape Test Failed Media is not detected Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Make sure that the drive firmware is at the latest level 4 Rerun the test after upgrading to the latest firmware level ...

Page 486: ...s Automatically notify support No User Response Complete the following steps 1 Check the tape drive cabling for loose or broken connections or damage to the cable Replace the cable if damage is present 2 Clean the tape drive using the appropriate cleaning media and install new media 3 Run the test again 4 Make sure that the drive firmware is at the latest level 5 Rerun the test after upgrading to ...

Page 487: ...DSA 264 906 000 Tape Test Failed Tape Test Failed Unrecognized error Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Make sure that the drive firmware is at the latest level 4 Rerun the test after upgrading to the latest f...

Page 488: ...t level of DSA 264 908 000 Tape Test Failed An error was found in getting tape capacity Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Make sure that medium is present 2 Clean the tape drive using the appropriate cleaning media and install new media Related links Lenovo Support website Latest level of DSA 474 System x3850 ...

Page 489: ...ected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error The event is a failure or critical condition that impairs service or an expected function Alert Category Similar events are grouped together in categories The alert category is in the following format severity deviceseverity is one of the following severity levels Critical A key c...

Page 490: ...oller arg1 Network Initialization Complete The IMM network subsystem initialization has completed May also be shown as 4000000100000000 or 0x4000000100000000 Severity Info Serviceable No Automatically notify support No Alert Category System IMM Network event SNMP Trap ID 37 CIM Information Prefix IMM ID 0001 User Response Information only no action is required 40000002 00000000 Certificate Authori...

Page 491: ...lex setting modified from arg1 to arg2 by user arg3 The specified user has changed the Ethernet duplex setting of the Integrated Management Module external network interface to the specified value May also be shown as 4000000400000000 or 0x4000000400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0004 User Response ...

Page 492: ...etwork interface to the specified value May also be shown as 4000000600000000 or 0x4000000600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0006 User Response Information only no action is required 40000007 00000000 Ethernet interface arg1 by user arg2 The specified user has enabled or disabled the Ethernet interfa...

Page 493: ... no action is required 40000009 00000000 IP address of network interface modified from arg1 to arg2 by user arg3 The specified user has changed the IP address of the Integrated Management Module external network interface to the specified value May also be shown as 4000000900000000 or 0x4000000900000000 Severity Info Serviceable No Automatically notify support No Alert Category System IMM Network ...

Page 494: ...specified user has changed the gateway address of the Integrated Management Module external network interface to the specified value May also be shown as 4000000b00000000 or 0x4000000b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0011 User Response Information only no action is required 4000000c 00000000 OS Watc...

Page 495: ...Response Complete the following steps until the problem is solved 1 Make sure that the IMM network cable is connected 2 Make sure that there is a DHCP server on the network that can assign an IP address to the IMM 4000000e 00000000 Remote Login Successful Login ID arg1 from arg2 at IP address arg3 The specified user has logged in to the Integrated Management Module May also be shown as 4000000e000...

Page 496: ...and has been prevented from logging in for the lockout period May also be shown as 4000001000000000 or 0x4000001000000000 Severity Warning Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0016 User Response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are be...

Page 497: ...sing an invalid login ID or password May also be shown as 4000001200000000 or 0x4000001200000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0018 User Response Make sure that the correct login ID and password are being used 40000013 00000000 Remote access attempt failed Invalid userid or password rece...

Page 498: ...ap ID CIM Information Prefix IMM ID 0020 User Response Information only no action is required 40000015 00000000 Management Controller arg1 reset was initiated by user arg2 The Integrated Management Module has been reset The logs provide additional details May also be shown as 4000001500000000 or 0x4000001500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNM...

Page 499: ...ess and configuration have been assigned using client data May also be shown as 4000001700000000 or 0x4000001700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0023 User Response Information only no action is required 40000018 00000000 LAN Ethernet arg1 interface is no longer active The IMM Ethernet interface has be...

Page 500: ...Trap ID CIM Information Prefix IMM ID 0025 User Response Information only no action is required 4000001a 00000000 DHCP setting changed to arg1 by user arg2 The specified user has changed the DHCP setting of the Integrated Management Module external network interface May also be shown as 4000001a00000000 or 0x4000001a00000000 Severity Info Serviceable No Automatically notify support No Alert Catego...

Page 501: ... operating system error has occurred and the screen capture was successful May also be shown as 4000001c00000000 or 0x4000001c00000000 Severity Info Serviceable No Automatically notify support No Alert Category System other SNMP Trap ID 22 CIM Information Prefix IMM ID 0028 User Response If there was no operating system error complete the following steps until the problem is solved 1 Reconfigure t...

Page 502: ...vels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4000001e 00000000 Running the backup Management Controller arg1 main application The IMM was unable to run the primary IMM image and has resorted to running the backup image May also be shown as 4000001e00000000 or 0x4000...

Page 503: ...f the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code Related links Updating the firmware IBM Flex System and IBM PureFlex Firmware Updates Best Practices 40000020 00000000 Management Controller arg1 Reset was caused by restoring default values The default configuration has been restored to the Integrated Ma...

Page 504: ...air that was previously generated through the Generate a New Key and Certificate Signing Request link May also be shown as 4000002200000000 or 0x4000002200000000 Severity Error Serviceable No Automatically notify support No Alert Category System other SNMP Trap ID 22 CIM Information Prefix IMM ID 0034 User Response Complete the following steps until the problem is solved 1 Make sure that the certi...

Page 505: ...ID 22 CIM Information Prefix IMM ID 0036 User Response Information only no action is required 40000025 00000000 The arg1 on system arg2 is 75 full The IMM event log is 75 full When the event log is completely full the new entries will overwrite the oldest entries To avoid losing older log entries save the log as a text file and clear the log May also be shown as 4000002500000000 or 0x4000002500000...

Page 506: ...027 00000000 Platform Watchdog Timer expired for arg1 A Platform Watchdog Timer Expired event has occurred May also be shown as 4000002700000000 or 0x4000002700000000 Severity Error Serviceable No Automatically notify support No Alert Category System OS Timeout SNMP Trap ID 21 CIM Information Prefix IMM ID 0039 User Response Complete the following steps until the problem is solved 1 Reconfigure th...

Page 507: ... from logging in for the lockout period May also be shown as 4000002900000000 or 0x4000002900000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0041 User Response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are being used 2 Have the syste...

Page 508: ... by user May also be shown as 4000002b00000000 or 0x4000002b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0043 User Response Information only no action is required 4000002c 00000000 Domain Source changed to arg1 by user arg2 Domain source changed by user May also be shown as 4000002c00000000 or 0x4000002c0000000...

Page 509: ...tion is required 4000002e 00000000 DDNS registration successful The domain name is arg1 The DDNS registration was successful May also be shown as 4000002e00000000 or 0x4000002e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0046 User Response Information only no action is required 4000002f 00000000 IPv6 enabled by...

Page 510: ...0 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0048 User Response Information only no action is required 40000031 00000000 IPv6 static IP configuration enabled by user arg1 The specified user has enabled IPv6 static address assignment on the Integrated Management Module May also be shown as 4000003100000000 or 0x4000003...

Page 511: ...nfiguration enabled by user arg1 IPv6 stateless address auto configuration has been enabled on the Integrated Management Module by the specified user May also be shown as 4000003300000000 or 0x4000003300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0051 User Response Information only no action is required 40000034...

Page 512: ...rviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0053 User Response Information only no action is required 40000036 00000000 IPv6 stateless auto configuration disabled by user arg1 IPv6 stateless address auto configuration has been disabled on the Integrated Management Module by the specified user May also be shown as 4000003600000000 or 0...

Page 513: ...o action is required 40000038 00000000 ENET arg1 IPv6 Static HstName arg2 IP arg3 Pref arg4 GW arg5 The IPv6 static address is active May also be shown as 4000003800000000 or 0x4000003800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0056 User Response Information only no action is required 40000039 00000000 ENET a...

Page 514: ...3a00000000 or 0x4000003a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0058 User Response Information only no action is required 4000003b 00000000 DHCPv6 failure no IP address assigned The DHCPv6 server has failed to assign an IP address to a management controller May also be shown as 4000003b00000000 or 0x400000...

Page 515: ...ader timeout SNMP Trap ID 26 CIM Information Prefix IMM ID 0060 User Response 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is enabled 3 Reinstall the RNDIS or cdc_ether device driver for the operating system 4 Disable the watchdog 5 Check the integrity of the installed operating system 4000003d 00000000 Telnet port number changed from arg1...

Page 516: ...g2 by user arg3 The specified user has changed the HTTP port number New HTTP web connections must use the new port number May also be shown as 4000003f00000000 or 0x4000003f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0063 User Response Information only no action is required 40000040 00000000 Web HTTPS port num...

Page 517: ...ity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0065 User Response Information only no action is required 40000042 00000000 CIM XML HTTPS port number changed from arg1 to arg2 by user arg3 The specified user has changed the CIM HTTPS port number May also be shown as 4000004200000000 or 0x4000004200000000 Severity Info Serviceab...

Page 518: ...0000 SNMP Traps port number changed from arg1 to arg2 by user arg3 The specified user has changed the Simple Network Management Protocol SNMP traps port number May also be shown as 4000004400000000 or 0x4000004400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0068 User Response Information only no action is require...

Page 519: ...000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0070 User Response Information only no action is required 40000047 00000000 LED arg1 state changed to arg2 by arg3 The specified LED has changed state May also be shown as 4000004700000000 or 0x4000004700000000 Severity Info Serviceable No Automatically notify support No ...

Page 520: ...equired 40000049 00000000 SNMP arg1 enabled by user arg2 The specified user has enabled the SNMPv1 or SNMPv3 agent May also be shown as 4000004900000000 or 0x4000004900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0073 User Response Information only no action is required 4000004a 00000000 SNMP arg1 disabled by use...

Page 521: ...tify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0075 User Response Information only no action is required 4000004c 00000000 LDAP Server configuration set by user arg1 SelectionMethod arg2 DomainName arg3 Server1 arg4 Server2 arg5 Server3 arg6 Server4 arg7 A user changed the LDAP server configuration May also be shown as 4000004c00000000 or 0x4000004c00000000 Severity...

Page 522: ...0004e 00000000 Serial Redirection set by user arg1 Mode arg2 BaudRate arg3 StopBits arg4 Parity arg5 SessionTerminateSequence arg6 A user configured the Serial Port mode May also be shown as 4000004e00000000 or 0x4000004e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0078 User Response Information only no action ...

Page 523: ...e shown as 4000005000000000 or 0x4000005000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0080 User Response Information only no action is required 40000051 00000000 Server Power Off Delay set to arg1 by user arg2 A user configured the Server Power Off Delay May also be shown as 4000005100000000 or 0x40000051000000...

Page 524: ...ion only no action is required 40000053 00000000 Server arg1 scheduled for every arg2 at arg3 by user arg4 A user configured a recurring Server Power Action May also be shown as 4000005300000000 or 0x4000005300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0083 User Response Information only no action is required 4...

Page 525: ... and Time synchronize settings May also be shown as 4000005500000000 or 0x4000005500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0085 User Response Information only no action is required 40000056 00000000 SMTP Server set by user arg1 to arg2 arg3 A user configured the SMTP server May also be shown as 400000560000...

Page 526: ...et by user arg1 UseAdditionalServers arg2 PreferredDNStype arg3 IPv4Server1 arg4 IPv4Server2 arg5 IPv4Server3 arg6 IPv6Server1 arg7 IPv6Server2 arg8 IPv6Server3 arg9 The specified user has configured the DNS servers May also be shown as 4000005800000000 or 0x4000005800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID ...

Page 527: ...n as 4000005a00000000 or 0x4000005a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0090 User Response Information only no action is required 4000005b 00000000 Secure Web services HTTPS arg1 by user arg2 A user enables or disables Secure web services May also be shown as 4000005b00000000 or 0x4000005b00000000 Sever...

Page 528: ...e Information only no action is required 4000005d 00000000 Secure LDAP arg1 by user arg2 A user enables or disables Secure LDAP services May also be shown as 4000005d00000000 or 0x4000005d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0093 User Response Information only no action is required 4000005e 00000000 SSH...

Page 529: ...f00000000 or 0x4000005f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0095 User Response Information only no action is required 40000060 00000000 License key for arg1 added by user arg2 A Integrated Management Module license that allows access to the specified feature was added to the system May also be shown as ...

Page 530: ...Response Information only no action is required 40000062 00000000 Global Login General Settings set by user arg1 AuthenticationMethod arg2 LockoutPeriod arg3 SessionTimeout arg4 A user changes the Global Login General Settings May also be shown as 4000006200000000 or 0x4000006200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Pre...

Page 531: ...ID CIM Information Prefix IMM ID 0099 User Response Information only no action is required 40000064 00000000 User arg1 created A user account has been created May also be shown as 4000006400000000 or 0x4000006400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0100 User Response Information only no action is required...

Page 532: ...Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0102 User Response Information only no action is required 40000067 00000000 User arg1 role set to arg2 A user account role assigned May also be shown as 4000006700000000 or 0x4000006700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNM...

Page 533: ...t AuthenticationProtocol arg2 PrivacyProtocol arg3 AccessType arg4 HostforTraps arg5 User account SNMPv3 settings changed May also be shown as 4000006900000000 or 0x4000006900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0105 User Response Information only no action is required 4000006a 00000000 SSH Client key add...

Page 534: ...fo Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0107 User Response Information only no action is required 4000006c 00000000 SSH Client key removed from user arg1 User removed an SSH Client key May also be shown as 4000006c00000000 or 0x4000006c00000000 Severity Info Serviceable No Automatically notify support No Alert Category none S...

Page 535: ...tryInterval arg3 EntryInterval arg4 A user changed the Global Event Notification settings May also be shown as 4000006e00000000 or 0x4000006e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0110 User Response Information only no action is required 4000006f 00000000 Alert Recipient Number arg1 updated Name arg2 Deli...

Page 536: ...0x4000007000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0112 User Response Information only no action is required 40000071 00000000 The power cap value changed from arg1 watts to arg2 watts by user arg3 The power capping level has been changed May also be shown as 4000007100000000 or 0x4000007100000000 Severity ...

Page 537: ...00073 00000000 The maximum power cap value changed from arg1 watts to arg2 watts The maximum power cap value has been changed May also be shown as 4000007300000000 or 0x4000007300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0115 User Response Information only no action is required 40000074 00000000 The soft minim...

Page 538: ... ID 164 CIM Information Prefix IMM ID 0117 User Response Make sure IMM firmware is at the latest level Raise the system power cap value or adjust the system workload to be less than the currently applied power cap Related links Updating the firmware IBM Flex System and IBM PureFlex Firmware Updates Best Practices 40000076 00000000 The new minimum power cap value exceeded the power cap value The ne...

Page 539: ... ID CIM Information Prefix IMM ID 0119 User Response Information only no action is required 40000078 00000000 Power capping was deactivated by user arg1 The power capping control has been disabled May also be shown as 4000007800000000 or 0x4000007800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0120 User Response ...

Page 540: ...ay also be shown as 4000007a00000000 or 0x4000007a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0122 User Response Information only no action is required 4000007b 00000000 Dynamic Power Savings mode has been turned on by user arg1 Dynamic Power Savings mode turned on by user May also be shown as 4000007b00000000...

Page 541: ...24 User Response Information only no action is required 4000007d 00000000 Power cap and external throttling occurred Power cap and external throttling has occurred May also be shown as 4000007d00000000 or 0x4000007d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0125 User Response Information only no action is req...

Page 542: ...7f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0127 User Response Information only no action is required 40000080 00000000 Remote Control session started by user arg1 in arg2 mode Remote Control session started May also be shown as 4000008000000000 or 0x4000008000000000 Severity Info Serviceable No Automaticall...

Page 543: ...urned below the power cap value The measured power value has returned below the power cap value May also be shown as 4000008200000000 or 0x4000008200000000 Severity Info Serviceable No Automatically notify support No Alert Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0130 User Response Information only no action is required 40000083 00000000 The new minimum power cap value...

Page 544: ...ly notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0132 User Response Attempt to update the IMM firmware to the same level on all nodes Related links Updating the firmware IBM Flex System and IBM PureFlex Firmware Updates Best Practices 40000085 00000000 FPGA firmware mismatch between nodes arg1 and arg2 Please attempt to flash the FPGA firmware to the s...

Page 545: ...4000008600000000 or 0x4000008600000000 Severity Info Serviceable No Automatically notify support Yes Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0134 User Response Information only no action is required 40000087 00000000 Manual Call Home by user arg1 arg2 The specified user has submitted a service request May also be shown as 4000008700000000 or 0x4000008700000000 Severity Info ...

Page 546: ...e by user arg2 failed to complete Restoration of the configuration of the specified management controller from a file by the specified user has not been completed May also be shown as 4000008900000000 or 0x4000008900000000 Severity Error Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0137 User Response 1 Turn off the server ...

Page 547: ...00 One or more of the Storage Management IP addresses has changed One or more of the Storage Management IP addresses has changed May also be shown as 4000008b00000000 or 0x4000008b00000000 Severity Info Serviceable No Automatically notify support No Alert Category System IMM Network event SNMP Trap ID 37 CIM Information Prefix IMM ID 0139 User Response Information only no action is required 400000...

Page 548: ...dress arg2 A user has attempted to log in from a CIM client by using an invalid login ID or password May also be shown as 4000008d00000000 or 0x4000008d00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0141 User Response Make sure that the correct login ID and password are being used 4000008e 00000...

Page 549: ...on Prefix IMM ID 0143 User Response Information only no action is required 40000090 00000000 The bare metal update application reports a status of arg1 Bare Metal Update Application Status May also be shown as 4000009000000000 or 0x4000009000000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0144 User Respon...

Page 550: ...arg9 A user configured the TKLM servers May also be shown as 4000009200000000 or 0x4000009200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0146 User Response Information only no action is required 40000093 00000000 TKLM servers device group set by user arg1 TKLMServerDeviceGroup arg2 A user configured the TKLM dev...

Page 551: ...y notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0148 User Response Information only no action is required 40000095 00000000 User arg1 has generated a new encryption key and certificate signing request for the TKLM client User generated a new encryption key and certificate signing request for the TKLM client May also be shown as 4000009500000000 or 0x4000009500000...

Page 552: ...orted a server certificate for the TKLM server User imported a server certificate for the TKLM Server May also be shown as 4000009700000000 or 0x4000009700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0151 User Response Information only no action is required 40000098 00000000 The UEFI Definitions have been changed...

Page 553: ...egory System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0153 User Response Information only no action is required 4000009a 00000000 Security Userid arg1 had arg2 login failures from SNMP client at IP address arg3 A user was not able to access a Management Controller from SNMP May also be shown as 4000009a00000000 or 0x4000009a00000000 Severity Info Serviceable No Automatically noti...

Page 554: ...ssful Login ID arg1 from arg2 serial interface A user successfully logged in to a Management Controller May also be shown as 4000009c00000000 or 0x4000009c00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0156 User Response Information only no action is required 4000009d 00000000 Login ID arg1 from...

Page 555: ... Trap ID 30 CIM Information Prefix IMM ID 0158 User Response Information only no action is required 4000009f 00000000 User arg1 has initiated a TKLM Server Connection Test to check connectivity to server arg2 User initiated a TKLM Server Connection test May also be shown as 4000009f00000000 or 0x4000009f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP ...

Page 556: ... May also be shown as 400000a100000000 or 0x400000a100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0161 User Response Information only no action is required 400000a2 00000000 User arg1 has arg2 file arg3 from arg4 User has mounted unmounted file from URL or server May also be shown as 400000a200000000 or 0x400000...

Page 557: ...SNMP Trap ID 22 CIM Information Prefix IMM ID 0163 User Response Information only no action is required 400000a4 00000000 User arg1 has removed a certificate User removed certificate May also be shown as 400000a400000000 or 0x400000a400000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0164 User Response Inf...

Page 558: ...own as 400000a600000000 or 0x400000a600000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0166 User Response Information only no action is required 400000a7 00000000 The server is restarted by chassis control command Server is restarted by chassis control command May also be shown as 400000a700000000 or 0x40...

Page 559: ...o action is required 400000a9 00000000 The server was powered up via power pushbutton Server was powered up via power pushbutton May also be shown as 400000a900000000 or 0x400000a900000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0169 User Response Information only no action is required 400000aa 00000000 ...

Page 560: ...matically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0171 User Response Information only no action is required 400000ac 00000000 The server was automatically powered on because the power restore policy is set to always restore Server was automatically powered on because the power restore policy is set to always restore May also be shown as 400000ac0...

Page 561: ...tegory System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0173 User Response Information only no action is required 400000ae 00000000 The server was reset via Platform Event Filter Server was reset via Platform Event Filter May also be shown as 400000ae00000000 or 0x400000ae00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM...

Page 562: ...00000b000000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0176 User Response Information only no action is required 400000b1 00000000 The server was powered up via Real Time Clock scheduled power on Server was powered up via Real Time Clock scheduled power on May also be shown as 400000b100000000 or 0x4000...

Page 563: ...ormation only no action is required 400000b3 00000000 The server was powered off by chassis control command Server was powered off by chassis control command May also be shown as 400000b300000000 or 0x400000b300000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0179 User Response Information only no action i...

Page 564: ...nfo Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0181 User Response Information only no action is required 400000b6 00000000 The server stayed powered off because the power restore policy is set to always restore Server stayed powered off because the power restore policy is set to always restore May also be shown as 400000...

Page 565: ... IMM ID 0183 User Response Information only no action is required 400000b8 00000000 The server was powered off via Platform Event Filter Server was power off via Platform Event Filter May also be shown as 400000b800000000 or 0x400000b800000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0184 User Response In...

Page 566: ...000000 or 0x400000ba00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0186 User Response Information only no action is required 400000bb 00000000 Management Controller arg1 reset was initiated by PRESET Management Controller reset was initiated by PRESET May also be shown as 400000bb00000000 or 0x400000bb...

Page 567: ...is required 400000bd 00000000 Management Controller arg1 reset was initiated by IMM firmware Management Controller reset was initiated by IMM firmware May also be shown as 400000bd00000000 or 0x400000bd00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0189 User Response Information only no action is requi...

Page 568: ...tomatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0191 User Response Information only no action is required 400000c0 00000000 Inventory data collecting and processing complete for arg1 Inventory data collecting and processing complete May also be shown as 400000c000000000 or 0x400000c000000000 Severity Info Serviceable No Automatically notify s...

Page 569: ...Name going low lower critical has asserted A Voltage has dropped below its specified threshold sensor SysBrd 12V SysBrd 3 3V or SysBrd 5V May also be shown as 800102020701ffff or 0x800102020701ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 0480 User Response 1 Trained service technician only If the ...

Page 570: ...tery 80010204 1d01ffff Numeric sensor NumericSensorElementName going low lower critical has asserted IMM has detected the speed of Fan 1A or Fan 1B has gone low May also be shown as 800102041d01ffff or 0x800102041d01ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the f...

Page 571: ...going low lower critical has asserted IMM has detected the speed of Fan 3A or Fan 3B has gone low May also be shown as 800102041d03ffff or 0x800102041d03ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan indicated by the lit LED on the fan 2 Replace Fan Re...

Page 572: ...speed of Fan 5A or Fan 5B has gone low May also be shown as 800102041d05ffff or 0x800102041d05ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan indicated by the lit LED on the fan 2 Replace Fan Related links Removing a hot swap fan assembly 80010204 1d06f...

Page 573: ...ow May also be shown as 800102041d07ffff or 0x800102041d07ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan indicated by the lit LED on the fan 2 Replace Fan Related links Removing a hot swap fan assembly 80010204 1d08ffff Numeric sensor NumericSensorElem...

Page 574: ...also be shown as 800102041d09ffff or 0x800102041d09ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan indicated by the lit LED on the fan 2 Replace Fan Related links Removing a hot swap fan assembly 80010204 1d0affff Numeric sensor NumericSensorElementName...

Page 575: ... Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifi...

Page 576: ...tected that the ambient temperature has risen above its upper critical threshold May also be shown as 800109012701ffff or 0x800109012701ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at...

Page 577: ... installed 3 Make sure that the room temperature is within operating specifications Related links Server features and specifications 80010902 0701ffff Numeric sensor NumericSensorElementName going high upper critical has asserted A voltage has risen above its specified threshold sensor SysBrd 12V SysBrd 3 3V or SysBrd 5V May also be shown as 800109020701ffff or 0x800109020701ffff Severity Error Se...

Page 578: ...ion Prefix PLAT ID 0498 User Response 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications Related links Server features and specifications 80010b01 2d01ffff Numeric sensor Numeri...

Page 579: ... SensorElementName has deasserted Secure UEFI Sig Verify Fail update completed Successfully May also be shown as 800300062101ffff or 0x800300062101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response Information only no action is required 80030108 1381ffff Sensor SensorElementName has asserted P...

Page 580: ...Center for the appropriate user response Related links Finding the UEFI POST error code 8003010d 2101ffff Sensor SensorElementName has asserted IMM has lost communication with the eXFlash IPMI Proxy Service The eXFlash DIMM device status is unknown May also be shown as 8003010d2101ffff or 0x8003010d2101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SN...

Page 581: ... code 8003010f 2101ffff Sensor SensorElementName has asserted IMM Firmware is Corrupted May also be shown as 8003010f2101ffff or 0x8003010f2101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Response Check that the primary build is correct and upgrade primary build to latest level 80030112 0601ffff ...

Page 582: ...ning Serviceable Yes Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0510 User Response Replace fan as soon as possible Related links Removing a hot swap fan assembly Replacing a hot swap fan assembly 80040104 1d02ffff Sensor SensorElementName is asserting predictive failure IMM predicted Fan 2 needs to be replaced to prevent a...

Page 583: ...ed Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0510 User Response Replace fan as soon as possible Related links Removing a hot swap fan assembly Replacing a hot swap fan assembly 80040104 1d04ffff Sensor SensorElementName is asserting predictive failure IMM predicted Fan 4 needs to be replaced to prevent a cooling failure May also be shown as 800401041d04ffff or 0x800401041d04ffff Sever...

Page 584: ...inks Removing a hot swap fan assembly Replacing a hot swap fan assembly 80040104 1d06ffff Sensor SensorElementName is asserting predictive failure IMM predicted Fan 6 needs to be replaced to prevent a cooling failure May also be shown as 800401041d06ffff or 0x800401041d06ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CI...

Page 585: ...M predicted Fan 8 needs to be replaced to prevent a cooling failure May also be shown as 800401041d08ffff or 0x800401041d08ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0510 User Response Replace fan as soon as possible Related links Removing a hot swap fan assembly Replacing a hot swap f...

Page 586: ...1d0affff or 0x800401041d0affff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0510 User Response Replace fan as soon as possible Related links Removing a hot swap fan assembly Replacing a hot swap fan assembly 8007000d 2582ffff Sensor SensorElementName has transitioned to normal state This mess...

Page 587: ...ation Prefix PLAT ID 0520 User Response 1 Check the IMM event log and resolve any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the Compute Book are not obstructed 3 Make sure that the room temperature is within operating specifications Related links Server features and specifications 80070101 0302ffff Sensor SensorElementName has transitioned from normal to n...

Page 588: ...erity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0520 User Response 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the Compute Book are not obstructed 3 Make sure that the room temperature is within operating specifications Related li...

Page 589: ...rning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0520 User Response Complete the following steps 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure tha...

Page 590: ...rom normal to non critical state PCI 3 temperature has risen above the critical level causing a hard shutdown of the node May also be shown as 800701010b03ffff or 0x800701010b03ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0520 User Response Complete the following steps 1 Check the IMM event l...

Page 591: ...at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications Related links Server features and specifications 80070101 0b05ffff Sensor SensorElementName has transitioned from normal to non critical state PCI 5 temperature has risen above the critical level causing a hard shutdown...

Page 592: ...egory Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0520 User Response Complete the following steps 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications Relat...

Page 593: ...atsink Related links Server features and specifications Removing and replacing components Thermal grease 80070107 0301ffff Sensor SensorElementName has transitioned from normal to non critical state The Compute Book 1 has been removed from the system System power blocked May also be shown as 800701070301ffff or 0x800701070301ffff Severity Warning Serviceable Yes Automatically notify support No Ale...

Page 594: ... May also be shown as 800701070303ffff or 0x800701070303ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links Replacing a compute book Removing a compute book 80070107 0304ffff Sensor SensorElementName has transitioned from normal to no...

Page 595: ...atically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Complete the following steps 1 Check the IBM ServerProven Web site to validate that the processor is a valid option for this system If not remove the processor and install one that is a valid option 2 Verify that matching processors are installed in the correct population seque...

Page 596: ...is reported Check if there is any other Power Supply event if PS ac input src 1 Check if there is any other Power Supply event 2 confirm power policy and configuration setting in Web GUI 3 check line feeds 4 check documentation for correct configuration Related links Solving power problems Installing power supplies 8007010d 2582ffff Sensor SensorElementName has transitioned from normal to non crit...

Page 597: ...No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b810002 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 2 in Compute Book 1 has less than 1 write warranty ...

Page 598: ...rt No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b810004 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 4 in Compute Book 1 has less than 1 write warran...

Page 599: ...tion Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b810006 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 6 in Compute Book 1 has less than 1 write warranty remaining May also be shown as 8007010d2b810006 or 0x800701...

Page 600: ... warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b810008 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 8 in Compute Book 1 has less than 1 write warranty remaining May also be shown as 8007010d2b810008 or 0x8007010d2b810008 Severity Warning Serviceable Yes Automatical...

Page 601: ... links eXFlash DIMMs 8007010d 2b81000a Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 10 in Compute Book 1 has less than 1 write warranty remaining May also be shown as 8007010d2b81000a or 0x8007010d2b81000a Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap I...

Page 602: ...al state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 12 in Compute Book 1 has less than 1 write warranty remaining May also be shown as 8007010d2b81000c or 0x8007010d2b81000c Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no...

Page 603: ... less than 1 write warranty remaining May also be shown as 8007010d2b81000e or 0x8007010d2b81000e Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b81000f Sensor SensorElementName ...

Page 604: ... May also be shown as 8007010d2b810010 or 0x8007010d2b810010 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b810011 Sensor SensorElementName has transitioned from normal to non c...

Page 605: ... as 8007010d2b810012 or 0x8007010d2b810012 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b810013 Sensor SensorElementName has transitioned from normal to non critical state The ...

Page 606: ... 0x8007010d2b810014 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b810015 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Serv...

Page 607: ...ning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b810017 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 2...

Page 608: ...omatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b81ffff Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated Compute Book 1 contains an eXFlash DIM...

Page 609: ...t No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b820002 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 2 in Compute Book 2 has less than 1 write warrant...

Page 610: ...mation Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b820004 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 4 in Compute Book 2 has less than 1 write warranty remaining May also be shown as 8007010d2b820004 or 0x8007...

Page 611: ...warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b820006 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 6 in Compute Book 2 has less than 1 write warranty remaining May also be shown as 8007010d2b820006 or 0x8007010d2b820006 Severity Warning Serviceable Yes Automaticall...

Page 612: ...ed links eXFlash DIMMs 8007010d 2b820008 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 8 in Compute Book 2 has less than 1 write warranty remaining May also be shown as 8007010d2b820008 or 0x8007010d2b820008 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ...

Page 613: ... state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 10 in Compute Book 2 has less than 1 write warranty remaining May also be shown as 8007010d2b82000a or 0x8007010d2b82000a Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no a...

Page 614: ...s less than 1 write warranty remaining May also be shown as 8007010d2b82000c or 0x8007010d2b82000c Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b82000d Sensor SensorElementName...

Page 615: ...ay also be shown as 8007010d2b82000e or 0x8007010d2b82000e Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b82000f Sensor SensorElementName has transitioned from normal to non cri...

Page 616: ...n as 8007010d2b820010 or 0x8007010d2b820010 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b820011 Sensor SensorElementName has transitioned from normal to non critical state The...

Page 617: ...0x8007010d2b820012 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b820013 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Servi...

Page 618: ...arning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b820015 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM...

Page 619: ...utomatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b820017 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 23 in Compute Book 2 ha...

Page 620: ...No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b82ffff Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated Compute Book 2 contains an eXFlash DIMM with less than 1 write w...

Page 621: ...tion Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b830002 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 2 in Compute Book 3 has less than 1 write warranty remaining May also be shown as 8007010d2b830002 or 0x800701...

Page 622: ... warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b830004 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 4 in Compute Book 3 has less than 1 write warranty remaining May also be shown as 8007010d2b830004 or 0x8007010d2b830004 Severity Warning Serviceable Yes Automatical...

Page 623: ... links eXFlash DIMMs 8007010d 2b830006 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 6 in Compute Book 3 has less than 1 write warranty remaining May also be shown as 8007010d2b830006 or 0x8007010d2b830006 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID...

Page 624: ...cal state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 8 in Compute Book 3 has less than 1 write warranty remaining May also be shown as 8007010d2b830008 or 0x8007010d2b830008 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no...

Page 625: ... less than 1 write warranty remaining May also be shown as 8007010d2b83000a or 0x8007010d2b83000a Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b83000b Sensor SensorElementName ...

Page 626: ... May also be shown as 8007010d2b83000c or 0x8007010d2b83000c Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b83000d Sensor SensorElementName has transitioned from normal to non c...

Page 627: ... as 8007010d2b83000e or 0x8007010d2b83000e Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b83000f Sensor SensorElementName has transitioned from normal to non critical state The ...

Page 628: ... 0x8007010d2b830010 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b830011 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Serv...

Page 629: ...ning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b830013 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 1...

Page 630: ...Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b830015 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 21 in Compute Book 3 h...

Page 631: ...t No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b830017 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 23 in Compute Book 3 has less than 1 write warran...

Page 632: ...on Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b83ffff Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated Compute Book 3 contains an eXFlash DIMM with less than 1 write warranty remaining May also be shown as 8007010d2b83ffff or 0x...

Page 633: ...warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b840002 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 2 in Compute Book 4 has less than 1 write warranty remaining May also be shown as 8007010d2b840002 or 0x8007010d2b840002 Severity Warning Serviceable Yes Automaticall...

Page 634: ...ed links eXFlash DIMMs 8007010d 2b840004 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 4 in Compute Book 4 has less than 1 write warranty remaining May also be shown as 8007010d2b840004 or 0x8007010d2b840004 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ...

Page 635: ...l state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 6 in Compute Book 4 has less than 1 write warranty remaining May also be shown as 8007010d2b840006 or 0x8007010d2b840006 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no a...

Page 636: ...s less than 1 write warranty remaining May also be shown as 8007010d2b840008 or 0x8007010d2b840008 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b840009 Sensor SensorElementName...

Page 637: ...ay also be shown as 8007010d2b84000a or 0x8007010d2b84000a Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b84000b Sensor SensorElementName has transitioned from normal to non cri...

Page 638: ...n as 8007010d2b84000c or 0x8007010d2b84000c Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b84000d Sensor SensorElementName has transitioned from normal to non critical state The...

Page 639: ...0x8007010d2b84000e Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b84000f Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Servi...

Page 640: ...arning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b840011 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM...

Page 641: ...utomatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b840013 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 19 in Compute Book 4 ha...

Page 642: ...rt No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b840015 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 21 in Compute Book 4 has less than 1 write warra...

Page 643: ...tion Prefix PLAT ID 0520 User Response Information only warranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b840017 Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 23 in Compute Book 4 has less than 1 write warranty remaining May also be shown as 8007010d2b840017 or 0x80070...

Page 644: ...rranty is about to expire but no action is required Related links eXFlash DIMMs 8007010d 2b84ffff Sensor SensorElementName has transitioned from normal to non critical state The eXFlash IPMI Proxy Service has indicated Compute Book 4 contains an eXFlash DIMM with less than 1 write warranty remaining May also be shown as 8007010d2b84ffff or 0x8007010d2b84ffff Severity Warning Serviceable Yes Automa...

Page 645: ...Recovery to Automatic 3 Replace the corrupt disk GPT Status Sec Rollback Err Secure Boot Err 80070114 2201ffff Sensor SensorElementName has transitioned from normal to non critical state Trusted Platform Module TPM event has transitioned to non critical state May also be shown as 800701142201ffff or 0x800701142201ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category ...

Page 646: ...severe state IMM has detected Compute Book 1 has warmed to a critical temperature May also be shown as 800702010301ffff or 0x800702010301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0522 User Response 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow a...

Page 647: ...s Server features and specifications 80070201 0303ffff Sensor SensorElementName has transitioned to critical from a less severe state IMM has detected Compute Book 3 has warmed to a critical temperature May also be shown as 800702010303ffff or 0x800702010303ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix ...

Page 648: ...d and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications Related links Server features and specifications 80070204 1381ffff Sensor SensorElementName has transitioned to critical from a less severe state Power Supply has detected a power supply fan fault May also be shown as 800702041381ffff or 0x800702041381ffff Severity Error...

Page 649: ...nd DC only Related links Solving power problems Installing power supplies Removing a 1400 watt or 900 watt hot swap power supply Removing a 750 watt 48 volt to 60 volt dc power supply Replacing a 1400 watt or 900 watt hot swap power supply Replacing a 750 watt 48 volt to 60 volt dc power supply 8007020c 2581ffff Sensor SensorElementName has transitioned to critical from a less severe state IMM has...

Page 650: ...ically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response RAID Vol State 8007020f 2201ffff Sensor SensorElementName has transitioned to critical from a less severe state The IMM has reported a Drive Key Fault or TXT ACM Module fault May also be shown as 8007020f2201ffff or 0x8007020f2201ffff Severity Error Serviceable yes Automatically...

Page 651: ...EFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 80070219 0701ffff Sensor SensorElementName has transitioned to critical from a less severe state The UEFI detected a critical System Board Fault May also be shown as 800702190701ffff or 0x800702190701ffff Severity Error Serviceable Yes Automatically notify support No Aler...

Page 652: ...on of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 8007021b 0302ffff Sensor SensorElementName has transitioned to critical from a less severe state IMM has reported a microprocessor 2 QPI Link Error May also be shown as 8007021b0302ffff or 0x8007021b0302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Ot...

Page 653: ... of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 8007021b 0304ffff Sensor SensorElementName has transitioned to critical from a less severe state IMM has reported a microprocessor 4 QPI Link Error May also be shown as 8007021b0304ffff or 0x8007021b0304ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Othe...

Page 654: ...t the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an ML2 Fault Condition Related links Server features and specifications 80070221 1f01ffff Sensor SensorElementName has transitioned to critical from a...

Page 655: ...r SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 80070221 1f03ffff Sensor SensorElementNam...

Page 656: ...y Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 80070221 2c01ffff Sensor S...

Page 657: ...sorElementName has transitioned to non recoverable from a less severe state IMM has detected that the temperature for microprocessor 1 has transitioned to a non recoverable state May also be shown as 800703010301ffff or 0x800703010301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0524 User Respon...

Page 658: ...ollowing steps until the problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Make sure that the microprocessor 2 heat sink is securely installed 5 Trained ser...

Page 659: ...e that the microprocessor 3 heat sink is installed correctly and the thermal material is correctly applied 6 Trained service technician only Replace microprocessor 3 Related links Server features and specifications Removing a microprocessor and heat sink Replacing a microprocessor and heat sink Thermal grease 80070301 0304ffff Sensor SensorElementName has transitioned to non recoverable from a les...

Page 660: ...ed a non recoverable Over temperature condition May also be shown as 800703012c01ffff or 0x800703012c01ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0522 User Response Complete the following steps until the problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make ...

Page 661: ... The S3 Resume Fail sesor has transitioned to non recoverable from less severe May also be shown as 800703192201ffff or 0x800703192201ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0524 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM m...

Page 662: ...the IO Module Storage Book VRD Indicates a problem with a voltage regulator for the Storage Book Board Check the IMM Web event log This event may be a symptom of an earlier error Depending on the error perform the following steps For a CPU BOOK 1 VRD CPU Book 2 VRD CPU Book 3 VRD or CPU Book 4 VRD error Check the IBM support site for service bulletins or firmware updates that apply to this micropr...

Page 663: ...t population sequence according to the product documentation for the system See the system documentation Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a microprocessor and heat sink Replacing a microprocessor and heat sink Thermal grease 80070607 2b01ffff Sensor SensorEleme...

Page 664: ...tion Prefix PLAT ID 0530 User Response if PS 12V OV Fault or PS 12V UV Fault or PS AUX UV Fault 1 Check the power supply LEDs see Power supply LEDs 2 Replace the failing power supply Related links Solving power problems Installing power supplies Removing a 1400 watt or 900 watt hot swap power supply Removing a 750 watt 48 volt to 60 volt dc power supply Replacing a 1400 watt or 900 watt hot swap p...

Page 665: ...y also be shown as 800706252583ffff or 0x800706252583ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0530 User Response Firmware of the PCI redrive card and NVME drive interface do not match Update the firmware 80070808 1381ffff Sensor SensorElementName has an informational state Power policies for eac...

Page 666: ...Trap ID CIM Information Prefix PLAT ID 0537 User Response Information only no action is required 80080025 2b01ffff Device LogicalDeviceElementName has been removed from unit PhysicalPackageElementName IMM has detected the Compute Book 1 has been removed from the system May also be shown as 800800252b01ffff or 0x800800252b01ffff Severity Info Serviceable No Automatically notify support No Alert Cat...

Page 667: ...erly seated replace the Compute Book Related links Replacing a compute book Removing a compute book 80080025 2b03ffff Device LogicalDeviceElementName has been removed from unit PhysicalPackageElementName IMM has detected the Compute Book 3 has been removed from the system May also be shown as 800800252b03ffff or 0x800800252b03ffff Severity Info Serviceable No Automatically notify support No Alert ...

Page 668: ... no action required 2 Make sure that the Compute Book is properly seated 3 If Compute Book is properly seated replace the Compute Book Related links Replacing a compute book Removing a compute book 80080025 2c01ffff Device LogicalDeviceElementName has been removed from unit PhysicalPackageElementName IMM has detected the I O Book 1 is no longer present Empty I O bays do require a filler be install...

Page 669: ...ity Info Serviceable no Automatically notify support no Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0537 User Response If the I O Book was intentionally removed no action required Make sure that the I O Book is properly seated If I O Book is properly seated replace the I O Book Related links Removing the half length I O book Replacing the half length I O book Removing t...

Page 670: ... only no action required 80080125 2b03ffff Device LogicalDeviceElementName has been added IMM has detected the Compute Book 3 has been added to the system May also be shown as 800801252b03ffff or 0x800801252b03ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0536 User Response Informational only no action requ...

Page 671: ...00801252c01ffff Severity Info Serviceable no Automatically notify support no Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0536 User Response Information only no action is required 80080125 2c02ffff Device LogicalDeviceElementName has been added IMM has detected the I O Book 2 has been added to the system May also be shown as 800801252c02ffff or 0x800801252c02ffff Severit...

Page 672: ... required 800b0008 1381ffff Redundancy RedundancySetElementName has been restored Power Supply Redundancy has been Restored May also be shown as 800b00081381ffff or 0x800b00081381ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Redundant Power Supply SNMP Trap ID 10 CIM Information Prefix PLAT ID 0561 User Response Information only no action is required 800b...

Page 673: ...750 watt 48 volt to 60 volt dc power supply 800b010a 1e81ffff Redundancy Lost for RedundancySetElementName has asserted Fan Redundancy in Zone 1 has been lost May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0802 User Response 1 Reseat the fai...

Page 674: ...also be shown as 800b010a1e83ffff or 0x800b010a1e83ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0802 User Response 1 Reseat the failing fan indicated by the lit LED on the fan 2 Replace Fan Related links Removing a hot swap fan assembly 800b010a 1e84ffff Redundancy Lost for RedundancySetElemen...

Page 675: ... or 0x800b010a1e85ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0802 User Response 1 Reseat the failing fan indicated by the lit LED on the fan 2 Replace Fan Related links Removing a hot swap fan assembly 800b010c 2581ffff Redundancy Lost for RedundancySetElementName has asserted Backup Memory ...

Page 676: ...ng Redundant Power Supply SNMP Trap ID 10 CIM Information Prefix PLAT ID 0804 User Response 1 Check if Power Supply is missing unplugged 2 Check the power supply LEDs see Power supply LEDs 3 Replace the affected power supply Related links Solving power problems Removing a 1400 watt or 900 watt hot swap power supply Removing a 750 watt 48 volt to 60 volt dc power supply Replacing a 1400 watt or 900...

Page 677: ...ndancySetElementName has asserted Power Resource is supplying sufficient power but is no longer in a redundancy state May also be shown as 800b03091381ffff or 0x800b03091381ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Redundant Power Supply SNMP Trap ID 10 CIM Information Prefix PLAT ID 0806 User Response 1 Power Unit Check if Power Supply is missing...

Page 678: ... redundant state and no longer capable of providing the power needs to operate the system May also be shown as 800b05081381ffff or 0x800b05081381ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Redundant Power Supply SNMP Trap ID 9 CIM Information Prefix PLAT ID 0810 User Response 1 Check if Power Supply is missing unplugged 2 Check the power supply LEDs ...

Page 679: ...power policy 3 Replace the affected power supply Related links Solving power problems Installing power supplies Removing a 1400 watt or 900 watt hot swap power supply Removing a 750 watt 48 volt to 60 volt dc power supply Replacing a 1400 watt or 900 watt hot swap power supply Replacing a 750 watt 48 volt to 60 volt dc power supply 800b050a 1e81ffff Non redundant Insufficient Resources for Redunda...

Page 680: ...n Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0810 User Response 1 Reseat the failing fan indicated by the lit LED on the fan 2 Replace Fan Related links Removing a hot swap fan assembly 800b050a 1e83ffff Non redundant Insufficient Resources for RedundancySetElementName has asserted Insufficient cooling provided by Fan Zone 3 May also be shown as 800b050a1e83ffff or 0x800b050a1e83ffff S...

Page 681: ...on Prefix PLAT ID 0810 User Response 1 Reseat the failing fan indicated by the lit LED on the fan 2 Replace Fan Related links Removing a hot swap fan assembly 800b050a 1e85ffff Non redundant Insufficient Resources for RedundancySetElementName has asserted Insufficient cooling provided by Fan Zone 5 May also be shown as 800b050a1e85ffff or 0x800b050a1e85ffff Severity Error Serviceable Yes Automatic...

Page 682: ...I diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0007 0301ffff ProcessorElementName has Failed with IERR IMM has reported microprocessor 1 failed IERR condition May also be shown as 806f00070301ffff or 0x806f00070301ffff Severity Error Serviceable Yes Automatically notify support No Alert C...

Page 683: ...fo Center for the appropriate user response Related links Finding the UEFI POST error code 806f0007 0303ffff ProcessorElementName has Failed with IERR IMM has reported microprocessor 3 failed IERR condition May also be shown as 806f00070303ffff or 0x806f00070303ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLA...

Page 684: ... the appropriate user response Related links Finding the UEFI POST error code 806f0008 0a01ffff PowerSupplyElementName has been added to container PhysicalPackageElementName IMM has detected that Power Supply 1 has been added May also be shown as 806f00080a01ffff or 0x806f00080a01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Informat...

Page 685: ... or 0x806f00080a03ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0084 User Response Information only no action is required 806f0008 0a04ffff PowerSupplyElementName has been added to container PhysicalPackageElementName IMM has detected that Power Supply 4 has been added May also be shown as 806f00080a04ffff ...

Page 686: ...esponse Host Power Information only no action is required 806f000d 0400ffff The NumericSensorElementName has been added Hard drive 0 has been installed May also be shown as 806f000d0400ffff or 0x806f000d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response Information only no ac...

Page 687: ...d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response Information only no action is required 806f000d 0403ffff The NumericSensorElementName has been added Hard drive 3 has been installed May also be shown as 806f000d0403ffff or 0x806f000d0403ffff Severity Info Serviceable No Au...

Page 688: ...on only no action is required 806f000d 0405ffff The NumericSensorElementName has been added Hard drive 5 has been installed May also be shown as 806f000d0405ffff or 0x806f000d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response Information only no action is required 806f000d 04...

Page 689: ...erviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response Information only no action is required 806f000d 0408ffff The NumericSensorElementName has been added Hard drive 8 has been installed May also be shown as 806f000d0408ffff or 0x806f000d0408ffff Severity Info Serviceable No Automatically notify suppor...

Page 690: ...ed 806f000d 040affff The NumericSensorElementName has been added Hard drive 10 has been installed May also be shown as 806f000d040affff or 0x806f000d040affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response Information only no action is required 806f000d 040bffff The NumericSensorEl...

Page 691: ...utomatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response Information only no action is required 806f000d 040dffff The NumericSensorElementName has been added Hard drive 13 has been installed May also be shown as 806f000d040dffff or 0x806f000d040dffff Severity Info Serviceable No Automatically notify support No Alert Cat...

Page 692: ...ard drive 15 has been installed May also be shown as 806f000d040fffff or 0x806f000d040fffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response Information only no action is required 806f000f 220101ff The System ComputerSystemElementName has detected no memory in the system IMM has rep...

Page 693: ...f000f220102ff or 0x806f000f220102ff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0132 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info C...

Page 694: ...806f000f220104ff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0795 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the approp...

Page 695: ...o be shown as 806f000f22010aff or 0x806f000f22010aff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0766 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code secti...

Page 696: ...socket voltage May also be shown as 806f000f22010cff or 0x806f000f22010cff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0050 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI d...

Page 697: ... has been a malfunction with the button May also be shown as 806f00131701ffff or 0x806f00131701ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0222 User Response If the NMI button has not been pressed complete the following steps 1 Make sure that the NMI button is not pressed 2 Replace the system board...

Page 698: ...verity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response Replace PCIe card Related links Installing an adapter Removing the half length I O book Removing the full length I O book 806f0021 0b02ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName IMM has detected ...

Page 699: ...iceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response Replace PCIe card Related links Installing an adapter Removing the half length I O book Removing the full length I O book 806f0021 0b04ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName IMM has detected a Fault in PCIe s...

Page 700: ...e Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response Replace PCIe card Related links Installing an adapter Removing the half length I O book Removing the full length I O book 806f0021 0b06ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName IMM has detected a Fault in PCIe slot 6 ...

Page 701: ... Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response Replace PCIe card Related links Installing an adapter Removing the half length I O book Removing the full length I O book 806f0021 0b08ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName IMM has detected a Fault in PCIe slot 8 M...

Page 702: ...e Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response Replace PCIe card Related links Installing an adapter Removing the half length I O book Removing the full length I O book 806f0021 0b0affff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName IMM has detected a Fault in PCIe slot 10...

Page 703: ... Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response Replace PCIe card Related links Installing an adapter Removing the half length I O book Removing the full length I O book 806f0021 0b0cffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName IMM has detected a Fault in PCIe slot 12 ...

Page 704: ...e Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response Replace PCIe card Related links Installing an adapter Removing the half length I O book Removing the full length I O book 806f0021 0b0effff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName IMM has detected a Fault in PCIe slot 17...

Page 705: ... Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response Replace PCIe card Related links Installing an adapter Removing the half length I O book Removing the full length I O book 806f0021 0b10ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName IMM has detected a Fault in PCIe slot 19 ...

Page 706: ...0330 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0021 2582ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSyste...

Page 707: ...ff or 0x806f00232101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0368 User Response Information only no action is required 806f0028 2101ffff Sensor SensorElementName is unavailable or degraded on management system ComputerSystemElementName Trusted Platform Module TPM initialization or start up commands hav...

Page 708: ...y no action is required 806f0107 0301ffff An Over Temperature Condition has been detected on ProcessorElementName The microprocessor 1 temperature has risen above the critical level causing a hard shutdown of the node May also be shown as 806f01070301ffff or 0x806f01070301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Info...

Page 709: ...e May also be shown as 806f01070302ffff or 0x806f01070302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0036 User Response Complete the following steps 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructe...

Page 710: ...orrectly installed 3 Make sure that the room temperature is within operating specifications 4 Make sure that the microprocessor 3 heat sink is securely installed 5 Trained service technician only Make sure that the microprocessor 3 heat sink is installed correctly and the thermal material is correctly applied 6 Trained service technician only Replace microprocessor 3 Related links Server features ...

Page 711: ...croprocessor 4 heat sink is installed correctly and the thermal material is correctly applied 6 Trained service technician only Replace microprocessor 4 Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a microprocessor and heat sink Replacing a microprocessor and heat sink The...

Page 712: ...matically notify support Yes Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0086 User Response 1 Check the log for additional Power Supply Failure 2 Replace the Power Supply if needed Related links Solving power problems Installing power supplies Removing a 1400 watt or 900 watt hot swap power supply Removing a 750 watt 48 volt to 60 volt dc power supply Replacing a 14...

Page 713: ...06f01080a04ffff or 0x806f01080a04ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0086 User Response 1 Check the log for additional Power Supply Failure 2 Replace the Power Supply if needed Related links Solving power problems Installing power supplies Removing a 1400 watt or 900 watt hot swap power sup...

Page 714: ... SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f010c 2b810001 Uncorrectable error dete...

Page 715: ...10002 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate use...

Page 716: ...0004 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 717: ...006 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 718: ...0008 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 719: ...00a Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 720: ...000c Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 721: ...00e Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 722: ...0010 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 723: ...012 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 724: ...0014 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 725: ...016 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 726: ...0c2b810018 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriat...

Page 727: ...001 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 728: ...0003 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 729: ...005 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 730: ...0007 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 731: ...09 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user r...

Page 732: ...000b Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 733: ...00d Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 734: ...000f Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 735: ...011 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 736: ...0013 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 737: ...015 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 738: ...0017 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 739: ...everity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user respo...

Page 740: ...0002 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 741: ...004 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 742: ...0006 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 743: ...008 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 744: ...000a Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 745: ...00c Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 746: ...000e Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 747: ...010 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 748: ...0012 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 749: ...014 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 750: ...0016 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 751: ...2b830018 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate ...

Page 752: ...0001 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 753: ...003 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 754: ...0005 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 755: ...007 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 756: ...0009 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 757: ...00b Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 758: ...000d Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 759: ...00f Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 760: ...0011 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 761: ...013 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 762: ...0015 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 763: ...017 Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user ...

Page 764: ...r Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related ...

Page 765: ... Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Check IBM Support site for Service Bulletins RETAIN tips related to your particular drive 2 Check IBM Support site for firmware updates related to your particular drive 3 Check for any other RAID related errors 4 Replace the drive Related link...

Page 766: ...d0403ffff or 0x806f010d0403ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Check IBM Support site for Service Bulletins RETAIN tips related to your particular drive 2 Check IBM Support site for firmware updates related to your particular drive 3 Check for any other RAID r...

Page 767: ...lt detected by the controller May also be shown as 806f010d0405ffff or 0x806f010d0405ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Check IBM Support site for Service Bulletins RETAIN tips related to your particular drive 2 Check IBM Support site for firmware updates rel...

Page 768: ...ch and 1 8 inch hot swap drives 806f010d 0407ffff The NumericSensorElementName has been disabled due to a detected fault The drive 7 has been disabled defunct due to a fault detected by the controller May also be shown as 806f010d0407ffff or 0x806f010d0407ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Pref...

Page 769: ...ated to your particular drive 3 Check for any other RAID related errors 4 Replace the drive Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f010d 0409ffff The NumericSensorElementName has been disabled due to a detected fault The drive 9 has been disabled defunct due to a fault detected by the controller May also be shown as 806f010d0...

Page 770: ...BM Support site for Service Bulletins RETAIN tips related to your particular drive 2 Check IBM Support site for firmware updates related to your particular drive 3 Check for any other RAID related errors 4 Replace the drive Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f010d 040bffff The NumericSensorElementName has been disabled du...

Page 771: ...t Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Check IBM Support site for Service Bulletins RETAIN tips related to your particular drive 2 Check IBM Support site for firmware updates related to your particular drive 3 Check for any other RAID related errors 4 Replace the drive Related links Removing 2 5 inch and 1 8 inch hot swap drives Repla...

Page 772: ...eable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Check IBM Support site for Service Bulletins RETAIN tips related to your particular drive 2 Check IBM Support site for firmware updates related to your particular drive 3 Check for any other RAID related errors 4 Replace the drive Related links Remov...

Page 773: ...esponse 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memo...

Page 774: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 775: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 776: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 777: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 778: ...book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b810007 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 7 in Compute Book 1 May also be shown as 806f010d2b810007 or 0x806f010d2b810007 Severity Error Serviceable Yes Automatically notify support...

Page 779: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 780: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 781: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 782: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 783: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 784: ...ook cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b81000e The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 14 in Compute Book 1 May also be shown as 806f010d2b81000e or 0x806f010d2b81000e Severity Error Serviceable Yes Automatically notify support...

Page 785: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 786: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 787: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 788: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 789: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 790: ...ook cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b810015 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 21 in Compute Book 1 May also be shown as 806f010d2b810015 or 0x806f010d2b810015 Severity Error Serviceable Yes Automatically notify support...

Page 791: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 792: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 793: ...rect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIM...

Page 794: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 795: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 796: ...book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b820004 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 4 in Compute Book 2 May also be shown as 806f010d2b820004 or 0x806f010d2b820004 Severity Error Serviceable Yes Automatically notify support...

Page 797: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 798: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 799: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 800: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 801: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 802: ...ook cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b82000b The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 11 in Compute Book 2 May also be shown as 806f010d2b82000b or 0x806f010d2b82000b Severity Error Serviceable Yes Automatically notify support...

Page 803: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 804: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 805: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 806: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 807: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 808: ...ook cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b820012 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 18 in Compute Book 2 May also be shown as 806f010d2b820012 or 0x806f010d2b820012 Severity Error Serviceable Yes Automatically notify support...

Page 809: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 810: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 811: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 812: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 813: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 814: ...book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b830001 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 1 in Compute Book 3 May also be shown as 806f010d2b830001 or 0x806f010d2b830001 Severity Error Serviceable Yes Automatically notify support...

Page 815: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 816: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 817: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 818: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 819: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 820: ...book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b830008 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 8 in Compute Book 3 May also be shown as 806f010d2b830008 or 0x806f010d2b830008 Severity Error Serviceable Yes Automatically notify support...

Page 821: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 822: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 823: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 824: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 825: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 826: ...ook cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b83000f The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 15 in Compute Book 3 May also be shown as 806f010d2b83000f or 0x806f010d2b83000f Severity Error Serviceable Yes Automatically notify support...

Page 827: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 828: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 829: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 830: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 831: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 832: ...ook cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b830016 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 22 in Compute Book 3 May also be shown as 806f010d2b830016 or 0x806f010d2b830016 Severity Error Serviceable Yes Automatically notify support...

Page 833: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 834: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 835: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 836: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 837: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 838: ...book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b840005 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 5 in Compute Book 4 May also be shown as 806f010d2b840005 or 0x806f010d2b840005 Severity Error Serviceable Yes Automatically notify support...

Page 839: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 840: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 841: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 842: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 843: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 844: ...ook cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b84000c The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 12 in Compute Book 4 May also be shown as 806f010d2b84000c or 0x806f010d2b84000c Severity Error Serviceable Yes Automatically notify support...

Page 845: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 846: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 847: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 848: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 849: ...ersists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memor...

Page 850: ...ook cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f010d 2b840013 The NumericSensorElementName has been disabled due to a detected fault The eXFlash Proxy Service detected a fault on the eXFlash DIMM 19 in Compute Book 4 May also be shown as 806f010d2b840013 or 0x806f010d2b840013 Severity Error Serviceable Yes Automatically notify support...

Page 851: ...k drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 Reinstall your eXFlash IPMI Proxy Service 3 Perform a full AC power cycle on the system 4 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify tha...

Page 852: ...cently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to t...

Page 853: ...ect and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM...

Page 854: ... Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Rem...

Page 855: ...ulletin or firmware update that applies to this eXFlash error 6 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement 7 Replace compute book 8 Trained Service technician only Replace affected Processor Related links Server features and specifications Removing a compute book Replacing a compute book Remov...

Page 856: ... 50 CIM Information Prefix PLAT ID 0224 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f011b 0701ffff The connector PhysicalConnectorElemen...

Page 857: ...Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0266 User Response Storage Book Card or Drive backplane cable FP LCD Cable Front Panel LCD cable 1 Remove the Storage Book 2 Check for missing or loose cables in the Storage Book 3 Check connector for damege or debris Related links Removing the storage book 806f0123 2101ffff Reboot of system ComputerSystemElementName ...

Page 858: ...ed no action required 2 Make sure that the Storage Book is properly seated 3 If Storage Book is properly seated replace the Storage Book Related links Removing the storage book board assembly Replacing the storage book board assembly 806f0207 0301ffff ProcessorElementName has Failed with FRB1 BIST condition IMM has reported a Miroprocessor 1 Failed FRB1 BIST condition May also be shown as 806f0207...

Page 859: ...U SNMP Trap ID 40 CIM Information Prefix PLAT ID 0044 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0207 0303ffff ProcessorElementName ha...

Page 860: ...CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0044 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0207 2583ffff ProcessorElementName ...

Page 861: ...Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response Replace the hard disk drive at the next maintenance period Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f020d 0401ffff Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Failure predicted PFA on the har...

Page 862: ...k drive at the next maintenance period Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f020d 0403ffff Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Failure predicted PFA on the hard drive 3 May also be shown as 806f020d0403ffff or 0x806f020d0403ffff Severity Warning Serviceable Yes Automatically not...

Page 863: ...oving 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f020d 0405ffff Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Failure predicted PFA on the hard drive 5 May also be shown as 806f020d0405ffff or 0x806f020d0405ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure ...

Page 864: ...nch hot swap drives 806f020d 0407ffff Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Failure predicted PFA on the hard drive 7 May also be shown as 806f020d0407ffff or 0x806f020d0407ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response Replac...

Page 865: ...stemElementName Failure predicted PFA on the hard drive 9 May also be shown as 806f020d0409ffff or 0x806f020d0409ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response Replace the hard disk drive at the next maintenance period Related links Removing 2 5 inch and 1 8 inch hot sw...

Page 866: ... May also be shown as 806f020d040bffff or 0x806f020d040bffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response Replace the hard disk drive at the next maintenance period Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives...

Page 867: ... as 806f020d040dffff or 0x806f020d040dffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response Replace the hard disk drive at the next maintenance period Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f020d 040effff...

Page 868: ... Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response Replace the hard disk drive at the next maintenance period Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f020d 2b810801 Failure Predicted on NumericSensorElementName for ...

Page 869: ...m persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b810802 Failure Predic...

Page 870: ...Flash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 3 in Compute Book 1 May also be shown as 806f020d2b810803 or 0x806f020d2b810803 Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash D...

Page 871: ...erly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware u...

Page 872: ... that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute boo...

Page 873: ...warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b810807 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure...

Page 874: ...d2b810808 or 0x806f020d2b810808 Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upg...

Page 875: ...erial in any DIMM connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persis...

Page 876: ...m 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Rep...

Page 877: ...res and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b81080c Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 12 in Compute Book ...

Page 878: ...e Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and v...

Page 879: ...M connector on that memory channel If either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are...

Page 880: ...eck IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing...

Page 881: ...g the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b810811 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 17 in Compute Book 1 May also be shown as 806f020d2b810811 or 0x806f020d2b810811 Severity Warning ...

Page 882: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 883: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 884: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 885: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b810816 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 22 in Compute Book 1 May also be shown as 806f020d2b810816 or 0x806f020d2b810816 Severity Warning Servicea...

Page 886: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 887: ...f either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the sam...

Page 888: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 889: ...ompute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b820803 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 3 in Compute Book 2 May also be shown as 806f020d2b820803 or 0x806f020d2b820803 Severity Warning Servicea...

Page 890: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 891: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 892: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 893: ...ompute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b820808 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 8 in Compute Book 2 May also be shown as 806f020d2b820808 or 0x806f020d2b820808 Severity Warning Servicea...

Page 894: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 895: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 896: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 897: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b82080d Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 13 in Compute Book 2 May also be shown as 806f020d2b82080d or 0x806f020d2b82080d Severity Warning Servicea...

Page 898: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 899: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 900: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 901: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b820812 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 18 in Compute Book 2 May also be shown as 806f020d2b820812 or 0x806f020d2b820812 Severity Warning Servicea...

Page 902: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 903: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 904: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 905: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b820817 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 23 in Compute Book 2 May also be shown as 806f020d2b820817 or 0x806f020d2b820817 Severity Warning Servicea...

Page 906: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 907: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 908: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 909: ...ompute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b830804 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 4 in Compute Book 3 May also be shown as 806f020d2b830804 or 0x806f020d2b830804 Severity Warning Servicea...

Page 910: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 911: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 912: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 913: ...ompute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b830809 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 9 in Compute Book 3 May also be shown as 806f020d2b830809 or 0x806f020d2b830809 Severity Warning Servicea...

Page 914: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 915: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 916: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 917: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b83080e Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 14 in Compute Book 3 May also be shown as 806f020d2b83080e or 0x806f020d2b83080e Severity Warning Servicea...

Page 918: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 919: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 920: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 921: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b830813 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 19 in Compute Book 3 May also be shown as 806f020d2b830813 or 0x806f020d2b830813 Severity Warning Servicea...

Page 922: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 923: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 924: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 925: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b830818 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 24 in Compute Book 3 May also be shown as 806f020d2b830818 or 0x806f020d2b830818 Severity Warning Servicea...

Page 926: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 927: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 928: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 929: ...ompute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b840805 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 5 in Compute Book 4 May also be shown as 806f020d2b840805 or 0x806f020d2b840805 Severity Warning Servicea...

Page 930: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 931: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 932: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 933: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b84080a Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 10 in Compute Book 4 May also be shown as 806f020d2b84080a or 0x806f020d2b84080a Severity Warning Servicea...

Page 934: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 935: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 936: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 937: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b84080f Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 15 in Compute Book 4 May also be shown as 806f020d2b84080f or 0x806f020d2b84080f Severity Warning Servicea...

Page 938: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 939: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 940: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 941: ...mpute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f020d 2b840814 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service reported a failure predicted PFA on the eXFlash DIMM 20 in Compute Book 4 May also be shown as 806f020d2b840814 or 0x806f020d2b840814 Severity Warning Servicea...

Page 942: ... Prefix PLAT ID 0168 User Response At the next maintenance opportunity 1 Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed 2 If the node has recently been installed moved serviced or upgraded verify that the eXFlash DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel If either of the...

Page 943: ... either of these conditions is found correct and retry with the same eXFlash DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 3 Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same...

Page 944: ...ort site for an applicable service bulletin or firmware update that applies to this eXFlash error 4 If problem persists and there are no other eXFLash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute...

Page 945: ...XFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0221 0b01ffff Package installed in slot PhysicalConnectorElementName for system ComputerSystemElementName IMM has detec...

Page 946: ...210b03ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0334 User Response Information only no action is required 806f0221 0b04ffff Package installed in slot PhysicalConnectorElementName for system ComputerSystemElementName IMM has detected that a card was was Installed in a PCIe slot 4 May also be shown as 806...

Page 947: ...d 806f0221 0b06ffff Package installed in slot PhysicalConnectorElementName for system ComputerSystemElementName IMM has detected that a card was was Installed in a PCIe slot 6 May also be shown as 806f02210b06ffff or 0x806f02210b06ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0334 User Response Information ...

Page 948: ...x806f03080a01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0100 User Response Information only no action is required 806f0308 0a02ffff PowerSupplyElementName has lost input Power Supply 2 AC input has been lost May also be shown as 806f03080a02ffff or 0x806f03080a02ffff Severity Info Serviceable No Automati...

Page 949: ...f PowerSupplyElementName has lost input Power Supply 4 AC input has been lost May also be shown as 806f03080a04ffff or 0x806f03080a04ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0100 User Response Information only no action is required 806f030c 2b810001 Scrub Failure for PhysicalMemoryElementName on Subsys...

Page 950: ...time error on DIMM 2 in Compute Book 1 May also be shown as 806f030c2b810002 or 0x806f030c2b810002 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI di...

Page 951: ...moryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 4 in Compute Book 1 May also be shown as 806f030c2b810004 or 0x806f030c2b810004 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for th...

Page 952: ...e UEFI POST error code 806f030c 2b810006 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 6 in Compute Book 1 May also be shown as 806f030c2b810006 or 0x806f030c2b810006 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Informa...

Page 953: ...ter for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b810008 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 8 in Compute Book 1 May also be shown as 806f030c2b810008 or 0x806f030c2b810008 Severity Error Serviceable Yes Automatically notify support...

Page 954: ... section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b81000a Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 10 in Compute Book 1 May also be shown as 806f030c2b81000a or 0x806f030c2b81000a Severity Error Serviceable Yes Aut...

Page 955: ... for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b81000c Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime e...

Page 956: ...al Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b81000e Scrub Failure f...

Page 957: ... Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b810010...

Page 958: ...fy support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error cod...

Page 959: ...lly notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST e...

Page 960: ...Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the U...

Page 961: ...viceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links ...

Page 962: ...ty Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Re...

Page 963: ...20002 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user...

Page 964: ...4 or 0x806f030c2b820004 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for th...

Page 965: ...806f030c2b820006 or 0x806f030c2b820006 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Inf...

Page 966: ...shown as 806f030c2b820008 or 0x806f030c2b820008 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section o...

Page 967: ...also be shown as 806f030c2b82000a or 0x806f030c2b82000a Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code s...

Page 968: ...ok 2 May also be shown as 806f030c2b82000c or 0x806f030c2b82000c Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnost...

Page 969: ...me error on DIMM 14 in Compute Book 2 May also be shown as 806f030c2b82000e or 0x806f030c2b82000e Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI dia...

Page 970: ...emoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 16 in Compute Book 2 May also be shown as 806f030c2b820010 or 0x806f030c2b820010 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for ...

Page 971: ...UEFI POST error code 806f030c 2b820012 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 18 in Compute Book 2 May also be shown as 806f030c2b820012 or 0x806f030c2b820012 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Informat...

Page 972: ...nter for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b820014 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 20 in Compute Book 2 May also be shown as 806f030c2b820014 or 0x806f030c2b820014 Severity Error Serviceable Yes Automatically notify suppo...

Page 973: ...section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b820016 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 22 in Compute Book 2 May also be shown as 806f030c2b820016 or 0x806f030c2b820016 Severity Error Serviceable Yes Auto...

Page 974: ...e for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b820018 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime ...

Page 975: ...ory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b830001 Scrub Failure for Phy...

Page 976: ...t Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b83000...

Page 977: ...y support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code...

Page 978: ...cally notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST...

Page 979: ...tomatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEF...

Page 980: ...rviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links...

Page 981: ...erity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response...

Page 982: ...b83000e Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate us...

Page 983: ...or 0x806f030c2b830010 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the ...

Page 984: ... 806f030c2b830012 or 0x806f030c2b830012 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the In...

Page 985: ...hown as 806f030c2b830014 or 0x806f030c2b830014 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of...

Page 986: ... also be shown as 806f030c2b830016 or 0x806f030c2b830016 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code ...

Page 987: ...e Book 3 May also be shown as 806f030c2b830018 or 0x806f030c2b830018 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diag...

Page 988: ...time error on DIMM 1 in Compute Book 4 May also be shown as 806f030c2b840001 or 0x806f030c2b840001 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI di...

Page 989: ...moryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 3 in Compute Book 4 May also be shown as 806f030c2b840003 or 0x806f030c2b840003 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for th...

Page 990: ...e UEFI POST error code 806f030c 2b840005 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 5 in Compute Book 4 May also be shown as 806f030c2b840005 or 0x806f030c2b840005 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Informa...

Page 991: ...ter for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b840007 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 7 in Compute Book 4 May also be shown as 806f030c2b840007 or 0x806f030c2b840007 Severity Error Serviceable Yes Automatically notify support...

Page 992: ...e section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b840009 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime error on DIMM 9 in Compute Book 4 May also be shown as 806f030c2b840009 or 0x806f030c2b840009 Severity Error Serviceable Yes Aut...

Page 993: ... for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b84000b Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName The IMM has reported a Memory POST failure during Boot not a runtime e...

Page 994: ...al Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b84000d Scrub Failure f...

Page 995: ... Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f030c 2b84000f...

Page 996: ...fy support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error cod...

Page 997: ...lly notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST e...

Page 998: ...Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the U...

Page 999: ...viceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links ...

Page 1000: ...018 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user r...

Page 1001: ...entName A hot spare drive is available May also be shown as 806f030d0400ffff or 0x806f030d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response Information only no action required 806f030d 0401ffff Hot Spare enabled for ComputerSystemElementName A hot spare drive is available May also be show...

Page 1002: ... 806f030d 0403ffff Hot Spare enabled for ComputerSystemElementName A hot spare drive is available May also be shown as 806f030d0403ffff or 0x806f030d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response Information only no action required 806f030d 0404ffff Hot Spare enabled for ComputerSystem...

Page 1003: ...le No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response Information only no action required 806f030d 0406ffff Hot Spare enabled for ComputerSystemElementName A hot spare drive is available May also be shown as 806f030d0406ffff or 0x806f030d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category Sy...

Page 1004: ...t Spare enabled for ComputerSystemElementName A hot spare drive is available May also be shown as 806f030d0408ffff or 0x806f030d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response Information only no action required 806f030d 0409ffff Hot Spare enabled for ComputerSystemElementName A hot spa...

Page 1005: ...rt No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response Information only no action required 806f030d 040bffff Hot Spare enabled for ComputerSystemElementName A hot spare drive is available May also be shown as 806f030d040bffff or 0x806f030d040bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Info...

Page 1006: ... ComputerSystemElementName A hot spare drive is available May also be shown as 806f030d040dffff or 0x806f030d040dffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response Information only no action required 806f030d 040effff Hot Spare enabled for ComputerSystemElementName A hot spare drive is availab...

Page 1007: ...fix PLAT ID 0170 User Response Information only no action required 806f0313 1701ffff A software NMI has occurred on system ComputerSystemElementName A software NMI has occurred Your system may have been rebooted depending on the configuration setting May also be shown as 806f03131701ffff or 0x806f03131701ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Ot...

Page 1008: ...stemElementName A mismatch of IMM firmware between nodes has been detected May also be shown as 806f032b2101ffff or 0x806f032b2101ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hardware Incompatibility SNMP Trap ID 36 CIM Information Prefix PLAT ID 0442 User Response Attempt to flash the IMM firmware to the same level on all nodes 806f032b 2e01ffff A fi...

Page 1009: ... ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b810001 PhysicalMemoryElementName Disabled on...

Page 1010: ...ty Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related li...

Page 1011: ...ically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST erro...

Page 1012: ... Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b810007 Physi...

Page 1013: ...ther SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b810009 PhysicalMemoryElementNa...

Page 1014: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b81000b PhysicalMemoryElementN...

Page 1015: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b81000d PhysicalMemoryElementNam...

Page 1016: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b81000f PhysicalMemoryElementN...

Page 1017: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b810011 PhysicalMemoryElementNam...

Page 1018: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b810013 PhysicalMemoryElementN...

Page 1019: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b810015 PhysicalMemoryElementNam...

Page 1020: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b810017 PhysicalMemoryElementN...

Page 1021: ...tem Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b81ffff PhysicalMemoryElem...

Page 1022: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820002 PhysicalMemoryElementN...

Page 1023: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820004 PhysicalMemoryElementNam...

Page 1024: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820006 PhysicalMemoryElementN...

Page 1025: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820008 PhysicalMemoryElementNam...

Page 1026: ...ther SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b82000a PhysicalMemoryElementNa...

Page 1027: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b82000c PhysicalMemoryElementNam...

Page 1028: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b82000e PhysicalMemoryElementN...

Page 1029: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820010 PhysicalMemoryElementNam...

Page 1030: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820012 PhysicalMemoryElementN...

Page 1031: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820014 PhysicalMemoryElementNam...

Page 1032: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820016 PhysicalMemoryElementN...

Page 1033: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b820018 PhysicalMemoryElementNam...

Page 1034: ... SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830001 PhysicalMemoryElementName D...

Page 1035: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830003 PhysicalMemoryElementNam...

Page 1036: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830005 PhysicalMemoryElementN...

Page 1037: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830007 PhysicalMemoryElementNam...

Page 1038: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830009 PhysicalMemoryElementN...

Page 1039: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b83000b PhysicalMemoryElementNam...

Page 1040: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b83000d PhysicalMemoryElementN...

Page 1041: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b83000f PhysicalMemoryElementNam...

Page 1042: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830011 PhysicalMemoryElementN...

Page 1043: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830013 PhysicalMemoryElementNam...

Page 1044: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830015 PhysicalMemoryElementN...

Page 1045: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b830017 PhysicalMemoryElementNam...

Page 1046: ...stem Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b83ffff PhysicalMemoryEle...

Page 1047: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840002 PhysicalMemoryElementNam...

Page 1048: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840004 PhysicalMemoryElementN...

Page 1049: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840006 PhysicalMemoryElementNam...

Page 1050: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840008 PhysicalMemoryElementN...

Page 1051: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b84000a PhysicalMemoryElementNam...

Page 1052: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b84000c PhysicalMemoryElementN...

Page 1053: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b84000e PhysicalMemoryElementNam...

Page 1054: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840010 PhysicalMemoryElementN...

Page 1055: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840012 PhysicalMemoryElementNam...

Page 1056: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840014 PhysicalMemoryElementN...

Page 1057: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840016 PhysicalMemoryElementNam...

Page 1058: ...Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f040c 2b840018 PhysicalMemoryElementN...

Page 1059: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0507 0301ffff ProcessorElementName has...

Page 1060: ...PU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0062 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0507 0303ffff ProcessorElementName h...

Page 1061: ... CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0062 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0507 2583ffff ProcessorElementName...

Page 1062: ...D 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810001 Memory Logging Limit Reached for Phy...

Page 1063: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810003 Memory Logging Limit Rea...

Page 1064: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810005 Memory Logging Limit R...

Page 1065: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810007 Memory Logging Limit Rea...

Page 1066: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810009 Memory Logging Limit R...

Page 1067: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b81000b Memory Logging Limit Rea...

Page 1068: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b81000d Memory Logging Limit R...

Page 1069: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b81000f Memory Logging Limit Rea...

Page 1070: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810011 Memory Logging Limit R...

Page 1071: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810013 Memory Logging Limit Rea...

Page 1072: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810015 Memory Logging Limit R...

Page 1073: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b810017 Memory Logging Limit Rea...

Page 1074: ... Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b81ffff Memory Logging Li...

Page 1075: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820002 Memory Logging Limit Rea...

Page 1076: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820004 Memory Logging Limit R...

Page 1077: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820006 Memory Logging Limit Rea...

Page 1078: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820008 Memory Logging Limit R...

Page 1079: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b82000a Memory Logging Limit Rea...

Page 1080: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b82000c Memory Logging Limit R...

Page 1081: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b82000e Memory Logging Limit Rea...

Page 1082: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820010 Memory Logging Limit R...

Page 1083: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820012 Memory Logging Limit Rea...

Page 1084: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820014 Memory Logging Limit R...

Page 1085: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820016 Memory Logging Limit Rea...

Page 1086: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b820018 Memory Logging Limit R...

Page 1087: ... Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830001 Memory Logging Limit Reached ...

Page 1088: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830003 Memory Logging Limit R...

Page 1089: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830005 Memory Logging Limit Rea...

Page 1090: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830007 Memory Logging Limit R...

Page 1091: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830009 Memory Logging Limit Rea...

Page 1092: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b83000b Memory Logging Limit R...

Page 1093: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b83000d Memory Logging Limit Rea...

Page 1094: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b83000f Memory Logging Limit R...

Page 1095: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830011 Memory Logging Limit Rea...

Page 1096: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830013 Memory Logging Limit R...

Page 1097: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830015 Memory Logging Limit Rea...

Page 1098: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b830017 Memory Logging Limit R...

Page 1099: ...Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b83ffff Memory Logging Lim...

Page 1100: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840002 Memory Logging Limit R...

Page 1101: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840004 Memory Logging Limit Rea...

Page 1102: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840006 Memory Logging Limit R...

Page 1103: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840008 Memory Logging Limit Rea...

Page 1104: ...y SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b84000a Memory Logging Limit Re...

Page 1105: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b84000c Memory Logging Limit Rea...

Page 1106: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b84000e Memory Logging Limit R...

Page 1107: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840010 Memory Logging Limit Rea...

Page 1108: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840012 Memory Logging Limit R...

Page 1109: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840014 Memory Logging Limit Rea...

Page 1110: ...ry SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840016 Memory Logging Limit R...

Page 1111: ... SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050c 2b840018 Memory Logging Limit Rea...

Page 1112: ... ID 0144 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f050d 0400ffff Array ComputerSystemElementName is in critical condition Drive 0 is ...

Page 1113: ...isk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drive that is indicated by a lit status LED Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f050d 0402ffff Array ComputerSystemElementName...

Page 1114: ...ry Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drive that is indicated by a lit status LED Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f050d 0404ffff Array Compute...

Page 1115: ... No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drive that is indicated by a lit status LED Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f050d 0406ff...

Page 1116: ...ify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drive that is indicated by a lit status LED Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f...

Page 1117: ...y notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drive that is indicated by a lit status LED Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives...

Page 1118: ...able Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drive that is indicated by a lit status LED Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8...

Page 1119: ...erity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drive that is indicated by a lit status LED Related links Removing 2 5 inch and 1 8 inch hot swap drives Replaci...

Page 1120: ...own as 806f050d040fffff or 0x806f050d040fffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drive that is indicated by a lit status LED Related links Remov...

Page 1121: ... User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0607 0302ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has asse...

Page 1122: ...tically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0816 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST ...

Page 1123: ... Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0816 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEF...

Page 1124: ...e SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drives that are indicated by a lit status LED Recreate the array Restore data from backup Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f060d 04...

Page 1125: ...Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drives that are indicated by a lit status LED Recreate the array Restore data from backup Related links Remo...

Page 1126: ...o be shown as 806f060d0404ffff or 0x806f060d0404ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drives that are indicated by a lit status LED Recreate ...

Page 1127: ...6 is part of an RAID array that is in the failed condition To identify drives in the failed array all member drives will report this message May also be shown as 806f060d0406ffff or 0x806f060d0406ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response Check IMM log for Predictive F...

Page 1128: ...e the array Restore data from backup Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f060d 0408ffff Array ComputerSystemElementName has failed Drive 8 is part of an RAID array that is in the failed condition To identify drives in the failed array all member drives will report this message May also be shown as 806f060d0408ffff or 0x806...

Page 1129: ...Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drives that are indicated by a lit status LED Recreate the array Restore data from backup Related links Removing 2 5 inch and 1 8 inch hot swap drives Replacing 2 5 inch and 1 8 inch hot swap drives 806f060d 040affff Array ComputerSystemElementName has failed Drive 10 is part ...

Page 1130: ...Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drives that are indicated by a lit status LED Recreate the array Restore data from backup Related links Removing 2 5 inch and 1 8 inch hot ...

Page 1131: ...dffff or 0x806f060d040dffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify failing drive s Replace the hard disk drives that are indicated by a lit status LED Recreate the array Restore data fr...

Page 1132: ...ion To identify drives in the failed array all member drives will report this message May also be shown as 806f060d040fffff or 0x806f060d040fffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response Check IMM log for Predictive Fault PFA or other hard drive messages to help identify ...

Page 1133: ...hysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 1 in Compute Book 1 May also be shown as 806f070c2b810001 or 0x806f070c2b810001 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detected event Th...

Page 1134: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 3 in Compute Book 1 May also be shown as 806f070c2b810003 or 0x806f070c2b810003 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1135: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 5 in Compute Book 1 May also be shown as 806f070c2b810005 or 0x806f070c2b810005 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detect...

Page 1136: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 7 in Compute Book 1 May also be shown as 806f070c2b810007 or 0x806f070c2b810007 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1137: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 9 in Compute Book 1 May also be shown as 806f070c2b810009 or 0x806f070c2b810009 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detect...

Page 1138: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 11 in Compute Book 1 May also be shown as 806f070c2b81000b or 0x806f070c2b81000b Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1139: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 13 in Compute Book 1 May also be shown as 806f070c2b81000d or 0x806f070c2b81000d Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1140: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 15 in Compute Book 1 May also be shown as 806f070c2b81000f or 0x806f070c2b81000f Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1141: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 17 in Compute Book 1 May also be shown as 806f070c2b810011 or 0x806f070c2b810011 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1142: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 19 in Compute Book 1 May also be shown as 806f070c2b810013 or 0x806f070c2b810013 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1143: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 21 in Compute Book 1 May also be shown as 806f070c2b810015 or 0x806f070c2b810015 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1144: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 23 in Compute Book 1 May also be shown as 806f070c2b810017 or 0x806f070c2b810017 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1145: ...ation Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on Compute Book 1 May also be shown as 806f070c2b81ffff or 0x806f070c2b81ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detected e...

Page 1146: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 2 in Compute Book 2 May also be shown as 806f070c2b820002 or 0x806f070c2b820002 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1147: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 4 in Compute Book 2 May also be shown as 806f070c2b820004 or 0x806f070c2b820004 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detect...

Page 1148: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 6 in Compute Book 2 May also be shown as 806f070c2b820006 or 0x806f070c2b820006 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1149: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 8 in Compute Book 2 May also be shown as 806f070c2b820008 or 0x806f070c2b820008 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detect...

Page 1150: ... Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 10 in Compute Book 2 May also be shown as 806f070c2b82000a or 0x806f070c2b82000a Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1151: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 12 in Compute Book 2 May also be shown as 806f070c2b82000c or 0x806f070c2b82000c Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1152: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 14 in Compute Book 2 May also be shown as 806f070c2b82000e or 0x806f070c2b82000e Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1153: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 16 in Compute Book 2 May also be shown as 806f070c2b820010 or 0x806f070c2b820010 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1154: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 18 in Compute Book 2 May also be shown as 806f070c2b820012 or 0x806f070c2b820012 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1155: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 20 in Compute Book 2 May also be shown as 806f070c2b820014 or 0x806f070c2b820014 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1156: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 22 in Compute Book 2 May also be shown as 806f070c2b820016 or 0x806f070c2b820016 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1157: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 24 in Compute Book 2 May also be shown as 806f070c2b820018 or 0x806f070c2b820018 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1158: ...or for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 1 in Compute Book 3 May also be shown as 806f070c2b830001 or 0x806f070c2b830001 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detected ...

Page 1159: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 3 in Compute Book 3 May also be shown as 806f070c2b830003 or 0x806f070c2b830003 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detect...

Page 1160: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 5 in Compute Book 3 May also be shown as 806f070c2b830005 or 0x806f070c2b830005 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1161: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 7 in Compute Book 3 May also be shown as 806f070c2b830007 or 0x806f070c2b830007 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detect...

Page 1162: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 9 in Compute Book 3 May also be shown as 806f070c2b830009 or 0x806f070c2b830009 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1163: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 11 in Compute Book 3 May also be shown as 806f070c2b83000b or 0x806f070c2b83000b Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1164: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 13 in Compute Book 3 May also be shown as 806f070c2b83000d or 0x806f070c2b83000d Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1165: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 15 in Compute Book 3 May also be shown as 806f070c2b83000f or 0x806f070c2b83000f Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1166: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 17 in Compute Book 3 May also be shown as 806f070c2b830011 or 0x806f070c2b830011 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1167: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 19 in Compute Book 3 May also be shown as 806f070c2b830013 or 0x806f070c2b830013 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1168: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 21 in Compute Book 3 May also be shown as 806f070c2b830015 or 0x806f070c2b830015 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1169: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 23 in Compute Book 3 May also be shown as 806f070c2b830017 or 0x806f070c2b830017 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1170: ...ration Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on Compute Book 3 May also be shown as 806f070c2b83ffff or 0x806f070c2b83ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detected ...

Page 1171: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 2 in Compute Book 4 May also be shown as 806f070c2b840002 or 0x806f070c2b840002 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detect...

Page 1172: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 4 in Compute Book 4 May also be shown as 806f070c2b840004 or 0x806f070c2b840004 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1173: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 6 in Compute Book 4 May also be shown as 806f070c2b840006 or 0x806f070c2b840006 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detect...

Page 1174: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 8 in Compute Book 4 May also be shown as 806f070c2b840008 or 0x806f070c2b840008 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI dete...

Page 1175: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 10 in Compute Book 4 May also be shown as 806f070c2b84000a or 0x806f070c2b84000a Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1176: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 12 in Compute Book 4 May also be shown as 806f070c2b84000c or 0x806f070c2b84000c Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1177: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 14 in Compute Book 4 May also be shown as 806f070c2b84000e or 0x806f070c2b84000e Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1178: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 16 in Compute Book 4 May also be shown as 806f070c2b840010 or 0x806f070c2b840010 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1179: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 18 in Compute Book 4 May also be shown as 806f070c2b840012 or 0x806f070c2b840012 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1180: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 20 in Compute Book 4 May also be shown as 806f070c2b840014 or 0x806f070c2b840014 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1181: ...Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 22 in Compute Book 4 May also be shown as 806f070c2b840016 or 0x806f070c2b840016 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI detec...

Page 1182: ...n Error for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that a Memory configuration error has occurred on DIMM 24 in Compute Book 4 May also be shown as 806f070c2b840018 or 0x806f070c2b840018 Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response This is a UEFI det...

Page 1183: ...elated links Finding the UEFI POST error code 806f070d 0400ffff Rebuild in progress for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild on Drive 0 is in Progress May also be shown as 806f070d0400ffff or 0x806f070d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Re...

Page 1184: ... Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response Information only no action is required 806f070d 0403ffff Rebuild in progress for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild on Drive 3 is in Progress May also be shown as 806f070d0403ffff or 0x806f070d0403ffff Severity Info...

Page 1185: ... in progress for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild on Drive 5 is in Progress May also be shown as 806f070d0405ffff or 0x806f070d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response Information only no action is required 806f070d 0406ffff Rebuild...

Page 1186: ...ble No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response Information only no action is required 806f070d 0408ffff Rebuild in progress for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild on Drive 8 is in Progress May also be shown as 806f070d0408ffff or 0x806f070d0408ffff Severity Info Servicea...

Page 1187: ...in system ComputerSystemElementName IMM has detected that an Array Rebuild on Drive 10 is in Progress May also be shown as 806f070d040affff or 0x806f070d040affff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response Information only no action is required 806f070d 040bffff Rebuild in progress for Array...

Page 1188: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response Information only no action is required 806f070d 040dffff Rebuild in progress for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild on Drive 13 is in Progress May also be shown as 806f070d040dffff or 0x806f070d040dffff Severity Info Serviceable No Automatically notify suppo...

Page 1189: ...s detected that an Array Rebuild on Drive 15 is in Progress May also be shown as 806f070d040fffff or 0x806f070d040fffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response Information only no action is required 806f072b 2101ffff A successful software or firmware change was detected on system Compute...

Page 1190: ...ff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0450 User Response Information only no action is required 806f0807 0301ffff ProcessorElementName has been Disabled IMM has reported that microprocessor 1 has been disabled May also be shown as 806f08070301ffff or 0x806f08070301ffff Severity Info Serviceable No Aut...

Page 1191: ...her SNMP Trap ID CIM Information Prefix PLAT ID 0061 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0807 0303ffff ProcessorElementName has...

Page 1192: ...m Other SNMP Trap ID CIM Information Prefix PLAT ID 0061 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0807 2583ffff ProcessorElementName...

Page 1193: ... SNMP Trap ID 50 CIM Information Prefix PLAT ID 0240 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0813 2582ffff An Uncorrectable Bus Err...

Page 1194: ...se This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Related links Finding the UEFI POST error code 806f0823 2101ffff Watchdog Timer interrupt occurred for WatchdogElementName The Watchdog Timer has expired...

Page 1195: ...f eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Remov...

Page 1196: ...he same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacin...

Page 1197: ... compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b810004 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 4 in Compute Book 1 has been throttled due to high temperature May also be shown as 806f090c2b810004 or 0x806f090c2b810004 Sev...

Page 1198: ... Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that th...

Page 1199: ...stalled 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists a...

Page 1200: ... FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute bo...

Page 1201: ...dication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory...

Page 1202: ...ng the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b81000a PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 10 in Compute Book 1 has been throttled due to high temperature May also be shown as 806f090c2b81000a or 0x806f090c2b81000a Severity Warning Serviceable yes Automatically ...

Page 1203: ...m Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications...

Page 1204: ...ake sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there ar...

Page 1205: ...W is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book...

Page 1206: ...ndication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memor...

Page 1207: ... the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b810010 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 16 in Compute Book 1 has been throttled due to high temperature May also be shown as 806f090c2b810010 or 0x806f090c2b810010 Severity Warning Serviceable yes Automatically no...

Page 1208: ...tem Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specificatio...

Page 1209: ...e sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are ...

Page 1210: ...FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute boo...

Page 1211: ...ication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory ...

Page 1212: ...ng the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b810016 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 22 in Compute Book 1 has been throttled due to high temperature May also be shown as 806f090c2b810016 or 0x806f090c2b810016 Severity Warning Serviceable yes Automatically ...

Page 1213: ...m Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications...

Page 1214: ...re that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no o...

Page 1215: ...DIMM FW is updated to the latest level 6 If a DIMM and it is the only DIMM with the this event replace the DIMM 7 If an eXFlash DIMM and it is the only eXFlash DIMM with the this event the device should be replaced confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute...

Page 1216: ...e eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b...

Page 1217: ...dule Replacing a memory module eXFlash DIMMs 806f090c 2b820003 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 3 in Compute Book 2 has been throttled due to high temperature May also be shown as 806f090c2b820003 or 0x806f090c2b820003 Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Pr...

Page 1218: ...g steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condit...

Page 1219: ... Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM i...

Page 1220: ...problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the ...

Page 1221: ...e are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b820008 PhysicalMemoryElementName on Subs...

Page 1222: ... eXFlash DIMMs 806f090c 2b820009 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 9 in Compute Book 2 has been throttled due to high temperature May also be shown as 806f090c2b820009 or 0x806f090c2b820009 Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Respons...

Page 1223: ... steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Conditi...

Page 1224: ...M Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM ...

Page 1225: ...oblem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the co...

Page 1226: ...re are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b82000e PhysicalMemoryElementName on Sub...

Page 1227: ...XFlash DIMMs 806f090c 2b82000f PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 15 in Compute Book 2 has been throttled due to high temperature May also be shown as 806f090c2b82000f or 0x806f090c2b82000f Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response...

Page 1228: ...ng steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condi...

Page 1229: ... Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM i...

Page 1230: ...problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the ...

Page 1231: ...e are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b820014 PhysicalMemoryElementName on Subs...

Page 1232: ...eXFlash DIMMs 806f090c 2b820015 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 21 in Compute Book 2 has been throttled due to high temperature May also be shown as 806f090c2b820015 or 0x806f090c2b820015 Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Respons...

Page 1233: ... steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Conditi...

Page 1234: ...M Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM ...

Page 1235: ...persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute ...

Page 1236: ...oving the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module 806f090c 2b830001 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 1 in Compute Book 3 has been throttled due to high temperature May also be shown as 806f090c2b830001 or 0x806f090c2b830001 Severity Warning Serviceable yes Automatically notify suppo...

Page 1237: ...30002 or 0x806f090c2b830002 Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fill...

Page 1238: ...structed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication re...

Page 1239: ...f eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Remov...

Page 1240: ...he same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacin...

Page 1241: ... compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b830007 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 7 in Compute Book 3 has been throttled due to high temperature May also be shown as 806f090c2b830007 or 0x806f090c2b830007 Sev...

Page 1242: ... Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that th...

Page 1243: ...talled 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists an...

Page 1244: ...FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute boo...

Page 1245: ...ication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory ...

Page 1246: ...ng the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b83000d PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 13 in Compute Book 3 has been throttled due to high temperature May also be shown as 806f090c2b83000d or 0x806f090c2b83000d Severity Warning Serviceable yes Automatically ...

Page 1247: ...m Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications...

Page 1248: ...ake sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there ar...

Page 1249: ...W is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book...

Page 1250: ...ndication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memor...

Page 1251: ... the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b830013 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 19 in Compute Book 3 has been throttled due to high temperature May also be shown as 806f090c2b830013 or 0x806f090c2b830013 Severity Warning Serviceable yes Automatically no...

Page 1252: ...tem Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specificatio...

Page 1253: ...e sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are ...

Page 1254: ...FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute boo...

Page 1255: ...ication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory ...

Page 1256: ...book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b83ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled Memory on Compute Book 3 has been throttled due to high temperature detected by the DIMM sensor May also be shown as 806f090c2b83ffff or 0x806f090c2b83ffff Severity Warning Serviceable Yes Automatically not...

Page 1257: ... the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persist...

Page 1258: ...letins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before repla...

Page 1259: ...d there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover ...

Page 1260: ...ash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b840005 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 5 in Compute Book 4 h...

Page 1261: ...tled due to high temperature May also be shown as 806f090c2b840006 or 0x806f090c2b840006 Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the...

Page 1262: ...ure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem...

Page 1263: ...etins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replac...

Page 1264: ...nd there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover...

Page 1265: ...h DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b84000b PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 11 in Compute Book 4 ha...

Page 1266: ...ottled due to high temperature May also be shown as 806f090c2b84000c or 0x806f090c2b84000c Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at t...

Page 1267: ...re that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem ...

Page 1268: ...letins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before repla...

Page 1269: ... there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover R...

Page 1270: ...ash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b840011 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 17 in Compute Book 4 ...

Page 1271: ...tled due to high temperature May also be shown as 806f090c2b840012 or 0x806f090c2b840012 Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the...

Page 1272: ...sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM proble...

Page 1273: ...etins RETAIN tips related to an throttled DIMM Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replac...

Page 1274: ...nd there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover...

Page 1275: ...h DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f090c 2b840017 PhysicalMemoryElementName on Subsystem MemoryElementName Throttled IMM determined DIMM 23 in Compute Book 4 ha...

Page 1276: ...ottled due to high temperature May also be shown as 806f090c2b840018 or 0x806f090c2b840018 Severity Warning Serviceable yes Automatically notify support no Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at t...

Page 1277: ... or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an throttled DIMM Condition 5 If the problem persists and there are no other DIMMs with the s...

Page 1278: ...att Make sure it is connected to 220V AC input 2 If using a 900 Watt rated power supply connected at either 110V or 220 V may need to upgrade to a 1400 Watt rated power supply connected at 220V Related links Server features and specifications Solving power problems Installing power supplies 806f0a07 0302ffff ProcessorElementName is operating in a Degraded State The microprocessor 2 is being thrott...

Page 1279: ...throttled due to thermal or power conditions May also be shown as 806f0a070303ffff or 0x806f0a070303ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning CPU SNMP Trap ID 42 CIM Information Prefix PLAT ID 0038 User Response Check the IMM event log for any fan cooling or power related issues For a thermal condition 1 Make sure that the airflow at the front and...

Page 1280: ...t the room temperature is within operating specifications For a power condition 1 If Power Supply Unit is rated 1400 Watt Make sure it is connected to 220V AC input 2 If using a 900 Watt rated power supply connected at either 110V or 220 V may need to upgrade to a 1400 Watt rated power supply connected at 220V Related links Server features and specifications Solving power problems Installing power...

Page 1281: ...sts and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b810002 An Over Temperature C...

Page 1282: ... book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b810003 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 3 in Compute Book 1 has an Over Temperature Condition May also be shown as 806f0a0c2b810003 or 0x806f0a0c2b810003 Severity Error Serviceable yes Automatically notify support...

Page 1283: ...t no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is...

Page 1284: ...at fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIM...

Page 1285: ...XFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing...

Page 1286: ...s with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module ...

Page 1287: ...fore replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b810009 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 9 in ...

Page 1288: ...ysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 10 in Compute Book 1 has an Over Temperature Condition May also be shown as 806f0a0c2b81000a or 0x806f0a0c2b81000a Severity Error Serviceable yes Automatically notify support no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is ...

Page 1289: ... Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips rela...

Page 1290: ...ications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm t...

Page 1291: ...lem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the comp...

Page 1292: ...MM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 8...

Page 1293: ...mpute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b810010 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 16 in Compute Book 1 has an Over Temperature Condition May also be shown as 806f0a0c2b810010 or 0x806f0a0c2b8...

Page 1294: ...ity Error Serviceable yes Automatically notify support no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correct...

Page 1295: ...hat the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem pe...

Page 1296: ...rvice Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty b...

Page 1297: ...e no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a...

Page 1298: ...MMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b810016 An Over Temperature Condition has been detected on the Phy...

Page 1299: ...le Replacing a memory module eXFlash DIMMs 806f0a0c 2b810017 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 23 in Compute Book 1 has an Over Temperature Condition May also be shown as 806f0a0c2b810017 or 0x806f0a0c2b810017 Severity Error Serviceable yes Automatically notify support no Alert Category Critical Tempe...

Page 1300: ...ort no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature ...

Page 1301: ... at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If the problem persists and there are no other DIMMs with the same indication replace the DIMM Related links Server ...

Page 1302: ...and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cove...

Page 1303: ...sts and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b820003 An Over Temperature C...

Page 1304: ... book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b820004 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 4 in Compute Book 2 has an Over Temperature Condition May also be shown as 806f0a0c2b820004 or 0x806f0a0c2b820004 Severity Error Serviceable yes Automatically notify support...

Page 1305: ...t no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is...

Page 1306: ...at fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIM...

Page 1307: ...XFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing...

Page 1308: ...s with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module ...

Page 1309: ...fore replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b82000a An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 10 in...

Page 1310: ...ysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 11 in Compute Book 2 has an Over Temperature Condition May also be shown as 806f0a0c2b82000b or 0x806f0a0c2b82000b Severity Error Serviceable yes Automatically notify support no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is ...

Page 1311: ... Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips rela...

Page 1312: ...ications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm t...

Page 1313: ...lem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the comp...

Page 1314: ...MM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 8...

Page 1315: ...mpute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b820011 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 17 in Compute Book 2 has an Over Temperature Condition May also be shown as 806f0a0c2b820011 or 0x806f0a0c2b8...

Page 1316: ...ity Error Serviceable yes Automatically notify support no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correct...

Page 1317: ...hat the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem pe...

Page 1318: ...rvice Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty b...

Page 1319: ...e no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a...

Page 1320: ...MMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b820017 An Over Temperature Condition has been detected on the Phy...

Page 1321: ...le Replacing a memory module eXFlash DIMMs 806f0a0c 2b820018 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 24 in Compute Book 2 has an Over Temperature Condition May also be shown as 806f0a0c2b820018 or 0x806f0a0c2b820018 Severity Error Serviceable yes Automatically notify support no Alert Category Critical Tempe...

Page 1322: ...0a0c2b82ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in...

Page 1323: ...site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under...

Page 1324: ...are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing...

Page 1325: ...Ms with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b830004 An Over Temperature Condition has been detected on the Phys...

Page 1326: ...dule Replacing a memory module eXFlash DIMMs 806f0a0c 2b830005 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 5 in Compute Book 3 has an Over Temperature Condition May also be shown as 806f0a0c2b830005 or 0x806f0a0c2b830005 Severity Error Serviceable yes Automatically notify support no Alert Category Critical Temp...

Page 1327: ...t no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is...

Page 1328: ...at fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIM...

Page 1329: ...XFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing...

Page 1330: ...s with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module ...

Page 1331: ...fore replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b83000b An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 11 in...

Page 1332: ...ysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 12 in Compute Book 3 has an Over Temperature Condition May also be shown as 806f0a0c2b83000c or 0x806f0a0c2b83000c Severity Error Serviceable yes Automatically notify support no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is ...

Page 1333: ... Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips rela...

Page 1334: ...ications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm t...

Page 1335: ...lem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the comp...

Page 1336: ...MM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 8...

Page 1337: ...mpute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b830012 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 18 in Compute Book 3 has an Over Temperature Condition May also be shown as 806f0a0c2b830012 or 0x806f0a0c2b8...

Page 1338: ...ity Error Serviceable yes Automatically notify support no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correct...

Page 1339: ...hat the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem pe...

Page 1340: ...rvice Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty b...

Page 1341: ...e no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a...

Page 1342: ...MMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b830018 An Over Temperature Condition has been detected on the Phy...

Page 1343: ...ing a memory module eXFlash DIMMs 806f0a0c 2b83ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM has detected an Over Temperature Condition for Memory on Compute Book 3 May also be shown as 806f0a0c2b83ffff or 0x806f0a0c2b83ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature S...

Page 1344: ...sues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If t...

Page 1345: ...ice Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty bef...

Page 1346: ...are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing...

Page 1347: ...Ms with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b840005 An Over Temperature Condition has been detected on the Phys...

Page 1348: ...dule Replacing a memory module eXFlash DIMMs 806f0a0c 2b840006 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 6 in Compute Book 4 has an Over Temperature Condition May also be shown as 806f0a0c2b840006 or 0x806f0a0c2b840006 Severity Error Serviceable yes Automatically notify support no Alert Category Critical Temp...

Page 1349: ...t no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is...

Page 1350: ...at fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIM...

Page 1351: ...Flash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing ...

Page 1352: ...s with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module ...

Page 1353: ...fore replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b84000c An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 12 in...

Page 1354: ...ysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 13 in Compute Book 4 has an Over Temperature Condition May also be shown as 806f0a0c2b84000d or 0x806f0a0c2b84000d Severity Error Serviceable yes Automatically notify support no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is ...

Page 1355: ... Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips rela...

Page 1356: ...ications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm t...

Page 1357: ...lem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the comp...

Page 1358: ...MM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 8...

Page 1359: ...mpute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b840013 An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName IMM determined DIMM 19 in Compute Book 4 has an Over Temperature Condition May also be shown as 806f0a0c2b840013 or 0x806f0a0c2b8...

Page 1360: ...ity Error Serviceable yes Automatically notify support no Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response Complete the following steps until problem is solved 1 Check the IMM event log for any fan or cooling related issues 2 Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correct...

Page 1361: ...hat the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed 3 Make sure that the room temperature is within operating specifications 4 Check IBM Support site for Service Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem pe...

Page 1362: ...rvice Bulletins RETAIN tips related to an Over Temperature Condition 5 If eXFlash DIMM make sure the eXFlash DIMM FW is updated to the latest level 6 If the DIMM problem persists and there are no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty b...

Page 1363: ...e no other DIMMs with the same indication replace the DIMM 7 If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a...

Page 1364: ...Ms with the same indication confirm that the eXFlash DIMM is under warranty before replacement Related links Server features and specifications Removing a compute book Replacing a compute book Removing the compute book cover Replacing the compute book cover Removing a memory module Replacing a memory module eXFlash DIMMs 806f0a0c 2b84ffff An Over Temperature Condition has been detected on the Phys...

Page 1365: ...s SensorElementName IMM has reported a Bus Fatal Error May also be shown as 806f0a132401ffff or 0x806f0a132401ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0244 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer...

Page 1366: ...k cover Replacing the compute book cover Removing a microprocessor and heat sink Replacing a microprocessor and heat sink Thermal grease Removing the standard I O book Replacing the standard I O book 81010002 2801ffff Numeric sensor NumericSensorElementName going low lower non critical has deasserted The CMOS battery has returned to a normal voltage level May also be shown as 810100022801ffff or 0...

Page 1367: ...as deasserted The CMOS battery has returned to a normal voltage level May also be shown as 810102022801ffff or 0x810102022801ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 0481 User Response Information only no action is required 81010204 1d01ffff Numeric sensor NumericSensorElementName going low lower...

Page 1368: ...eable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0481 User Response Information only no action is required 81010204 1d03ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted IMM has detected Fan 3A or Fan 3B has recovered from a low speed condition May also be shown as 810102041d03ffff or 0x81...

Page 1369: ...or NumericSensorElementName going low lower critical has deasserted IMM has detected Fan 5A or Fan 5B has recovered from a low speed condition May also be shown as 810102041d05ffff or 0x810102041d05ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0481 User Response Information only no action is requ...

Page 1370: ...ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0481 User Response Information only no action is required 81010204 1d08ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted IMM has detected Fan 8A or Fan 8B has recovered from a low speed condition May also be shown as...

Page 1371: ...1d0affff Numeric sensor NumericSensorElementName going low lower critical has deasserted IMM has detected Fan 10A or Fan 10B has recovered from a low speed condition May also be shown as 810102041d0affff or 0x810102041d0affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0481 User Response Information...

Page 1372: ... 0x810107012d01ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0491 User Response Information only no action is required 81010901 2701ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted IMM has detected that the ambient temperature has returned to a normal range May...

Page 1373: ...re SNMP Trap ID 0 CIM Information Prefix PLAT ID 0495 User Response Information only no action is required 81010902 0701ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted A previously high voltage has returned to below its specified threshold sensor SysBrd 12V SysBrd 3 3V or SysBrd 5V May also be shown as 810109020701ffff or 0x810109020701ffff Severity Info Servi...

Page 1374: ...icSensorElementName going high upper non recoverable has deasserted IMM has detected that the PCH temperature has returned to a normal range May also be shown as 81010b012d01ffff or 0x81010b012d01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0499 User Response Information only no action is require...

Page 1375: ...103000f2101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Response Check that the primary build is correct and upgrade primary build to latest level 81030108 1381ffff Sensor SensorElementName has deasserted IMM has detected that PS Heavy Load sensor has cleared the reported error May also be shown ...

Page 1376: ...ensorElementName has deasserted An eXFlash DIMM firmware configuration error has deasserted on eXFlash DIMM in Compute Book 1 May also be shown as 8103010d2101ffff or 0x8103010d2101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response Information only no action is required 8103010e 2581ffff Senso...

Page 1377: ...erviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response Information only no action required 81040104 1d01ffff Sensor SensorElementName is deasserting predictive failure IMM has detected that Fan 1 has recovered from a predictive failure PFA May also be shown as 810401041d01ffff or 0x810401041d01ffff Severity Info Serv...

Page 1378: ... SensorElementName is deasserting predictive failure IMM has detected that Fan 3 has recovered from a predictive failure PFA May also be shown as 810401041d03ffff or 0x810401041d03ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0511 User Response Information only no action is required 81040104 ...

Page 1379: ...tomatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0511 User Response Information only no action is required 81040104 1d06ffff Sensor SensorElementName is deasserting predictive failure IMM has detected that Fan 6 has recovered from a predictive failure PFA May also be shown as 810401041d06ffff or 0x810401041d06ffff Severity Info Se...

Page 1380: ... deasserting predictive failure IMM has detected that Fan 8 has recovered from a predictive failure PFA May also be shown as 810401041d08ffff or 0x810401041d08ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0511 User Response Information only no action is required 81040104 1d09ffff Sensor Senso...

Page 1381: ...No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0511 User Response Information only no action is required 81070101 0301ffff Sensor SensorElementName has deasserted the transition from normal to non critical state IMM has detected that Compute Book 1 has returned to a normal temperature May also be shown as 810701010301ffff or 0x810701010301ffff Severity In...

Page 1382: ...ame has deasserted the transition from normal to non critical state IMM has detected that Compute Book 3 has returned to a normal temperature May also be shown as 810701010303ffff or 0x810701010303ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0521 User Response Information only no action is requir...

Page 1383: ...fff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0521 User Response Information only no action is required 81070101 0b02ffff Sensor SensorElementName has deasserted the transition from normal to non critical state PCI 2 over temperature has recovered May also be shown as 810701010b02ffff or 0x81070101...

Page 1384: ...s required 81070101 0b04ffff Sensor SensorElementName has deasserted the transition from normal to non critical state PCI 4 over temperature has recovered May also be shown as 810701010b04ffff or 0x810701010b04ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0521 User Response Information only no act...

Page 1385: ...rity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0521 User Response Information only no action is required 81070101 2c01ffff Sensor SensorElementName has deasserted the transition from normal to non critical state IMM has detected that the ML2 Card has recovered from a Over temperature condition May also be s...

Page 1386: ...x PLAT ID 0521 User Response Information only no action is required 81070107 0302ffff Sensor SensorElementName has deasserted the transition from normal to non critical state The Compute Book 2 has been added to the system May also be shown as 810701070302ffff or 0x810701070302ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Informa...

Page 1387: ...been added to the system May also be shown as 810701070304ffff or 0x810701070304ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0521 User Response Information only no action is required 81070107 2583ffff Sensor SensorElementName has deasserted the transition from normal to non critical state IMM has detec...

Page 1388: ...t Category Warning Power SNMP Trap ID 164 CIM Information Prefix PLAT ID 0521 User Response Information only no action is required 8107010d 2582ffff Sensor SensorElementName has deasserted the transition from normal to non critical state This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non critical from normal May also be shown as 81...

Page 1389: ... User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b810002 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 2 in Compute Book 1 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b810002 or 0x8107010d2b810002 Severity Warning Serviceable Yes Automati...

Page 1390: ...d links eXFlash DIMMs 8107010d 2b810004 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 4 in Compute Book 1 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b810004 or 0x8107010d2b810004 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Tr...

Page 1391: ...state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 6 in Compute Book 1 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b810006 or 0x8107010d2b810006 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links...

Page 1392: ...easserted the 10 write warrenty Sensor May also be shown as 8107010d2b810008 or 0x8107010d2b810008 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b810009 Sensor SensorElementName has deasserted the transition t...

Page 1393: ...ay also be shown as 8107010d2b81000a or 0x8107010d2b81000a Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b81000b Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Pr...

Page 1394: ...n as 8107010d2b81000c or 0x8107010d2b81000c Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b81000d Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has...

Page 1395: ...x8107010d2b81000e Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b81000f Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 15...

Page 1396: ...rning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b810011 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 17 in Compute Book 1 has deasse...

Page 1397: ...tomatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b810013 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 19 in Compute Book 1 has deasserted the 10 write warren...

Page 1398: ...rt No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b810015 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 21 in Compute Book 1 has deasserted the 10 write warrenty Sensor May also be sh...

Page 1399: ...D 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b810017 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 23 in Compute Book 1 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b810017 or 0x8107010d2b810017 ...

Page 1400: ...lated links eXFlash DIMMs 8107010d 2b81ffff Sensor SensorElementName has deasserted the transition to non critical state The IMM has detected that the Sensor deasserted May also be shown as 8107010d2b81ffff or 0x8107010d2b81ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information...

Page 1401: ...sserted the 10 write warrenty Sensor May also be shown as 8107010d2b820002 or 0x8107010d2b820002 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b820003 Sensor SensorElementName has deasserted the transition to ...

Page 1402: ...May also be shown as 8107010d2b820004 or 0x8107010d2b820004 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b820005 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI P...

Page 1403: ...as 8107010d2b820006 or 0x8107010d2b820006 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b820007 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has i...

Page 1404: ... 0x8107010d2b820008 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b820009 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM ...

Page 1405: ...ning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b82000b Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 11 in Compute Book 2 has deasser...

Page 1406: ...Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b82000d Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 13 in Compute Book 2 has deasserted the 10 write warr...

Page 1407: ... No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b82000f Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 15 in Compute Book 2 has deasserted the 10 write warrenty Sensor May also be show...

Page 1408: ...ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b820011 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 17 in Compute Book 2 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b820011 or 0x8107010d2b820011...

Page 1409: ...User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b820013 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 19 in Compute Book 2 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b820013 or 0x8107010d2b820013 Severity Warning Serviceable Yes Automati...

Page 1410: ...d links eXFlash DIMMs 8107010d 2b820015 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 21 in Compute Book 2 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b820015 or 0x8107010d2b820015 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP T...

Page 1411: ...state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 23 in Compute Book 2 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b820017 or 0x8107010d2b820017 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related link...

Page 1412: ...ay also be shown as 8107010d2b82ffff or 0x8107010d2b82ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required 8107010d 2b830001 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eX...

Page 1413: ...x8107010d2b830002 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b830003 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 3 ...

Page 1414: ...rning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b830005 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 5 in Compute Book 3 has deasser...

Page 1415: ...tomatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b830007 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 7 in Compute Book 3 has deasserted the 10 write warrent...

Page 1416: ...rt No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b830009 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 9 in Compute Book 3 has deasserted the 10 write warrenty Sensor May also be sho...

Page 1417: ...D 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b83000b Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 11 in Compute Book 3 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b83000b or 0x8107010d2b83000b ...

Page 1418: ...0 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b83000d Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 13 in Compute Book 3 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b83000d or 0x8107010d2b83000d Severity Warning Serviceable Yes Automa...

Page 1419: ...links eXFlash DIMMs 8107010d 2b83000f Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 15 in Compute Book 3 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b83000f or 0x8107010d2b83000f Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Tra...

Page 1420: ... state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 17 in Compute Book 3 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b830011 or 0x8107010d2b830011 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related lin...

Page 1421: ...sserted the 10 write warrenty Sensor May also be shown as 8107010d2b830013 or 0x8107010d2b830013 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b830014 Sensor SensorElementName has deasserted the transition to ...

Page 1422: ...May also be shown as 8107010d2b830015 or 0x8107010d2b830015 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b830016 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI P...

Page 1423: ...as 8107010d2b830017 or 0x8107010d2b830017 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b830018 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has i...

Page 1424: ...able Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required 8107010d 2b840001 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 1 in Compute Book 4 has deasserted the 10 write warrenty Sensor May also...

Page 1425: ...tify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b840003 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 3 in Compute Book 4 has deasserted the 10 write warrenty Sensor May a...

Page 1426: ...egory Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b840005 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 5 in Compute Book 4 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2...

Page 1427: ...mation Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b840007 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 7 in Compute Book 4 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b840007 or 0x8107010d2b840007 Severity Warnin...

Page 1428: ... Related links eXFlash DIMMs 8107010d 2b840009 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 9 in Compute Book 4 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b840009 or 0x8107010d2b840009 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other ...

Page 1429: ...state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 11 in Compute Book 4 has deasserted the 10 write warrenty Sensor May also be shown as 8107010d2b84000b or 0x8107010d2b84000b Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related link...

Page 1430: ...easserted the 10 write warrenty Sensor May also be shown as 8107010d2b84000d or 0x8107010d2b84000d Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b84000e Sensor SensorElementName has deasserted the transition t...

Page 1431: ...ay also be shown as 8107010d2b84000f or 0x8107010d2b84000f Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b840010 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Pr...

Page 1432: ...n as 8107010d2b840011 or 0x8107010d2b840011 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b840012 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has...

Page 1433: ...x8107010d2b840013 Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b840014 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 20...

Page 1434: ...rning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b840016 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 22 in Compute Book 4 has deasse...

Page 1435: ...tomatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Information only no action is required Related links eXFlash DIMMs 8107010d 2b840018 Sensor SensorElementName has deasserted the transition to non critical state The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 24 in Compute Book 4 has deasserted the 10 write warren...

Page 1436: ... only no action is required 8107010f 2201ffff Sensor SensorElementName has deasserted the transition from normal to non critical state The GPT GUID Partition Table in the disk LUN Logical Unit Number has returned to normal May also be shown as 8107010f2201ffff or 0x8107010f2201ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Informa...

Page 1437: ... X8 PCIe1 Config or X8 PCIe2 Config error has been removed May also be shown as 810701252583ffff or 0x810701252583ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0521 User Response Information only no action is required 81070201 0301ffff Sensor SensorElementName has transitioned to a less severe state fro...

Page 1438: ...atically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0523 User Response Information only no action is required 81070201 0303ffff Sensor SensorElementName has transitioned to a less severe state from critical IMM has detected the Compute Book 3 has cooled below the critial temperature level May also be shown as 810702010303ffff or 0x8107020103...

Page 1439: ...entName has transitioned to a less severe state from critical Power Supply has determined a PS Fan Fault has transition to less severe from critical May also be shown as 810702041381ffff or 0x810702041381ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0523 User Response Information only no action i...

Page 1440: ... No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response Information only no action is required 8107020d 2582ffff Sensor SensorElementName has transitioned to a less severe state from critical This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be sh...

Page 1441: ...equired 8107020f 2582ffff Sensor SensorElementName has transitioned to a less severe state from critical IMM has reported that the No I O Resources sensor has transitioned to a less severe state May also be shown as 8107020f2582ffff or 0x8107020f2582ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 Us...

Page 1442: ...k Error May also be shown as 8107021b0301ffff or 0x8107021b0301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response Information only no action is required 8107021b 0302ffff Sensor SensorElementName has transitioned to a less severe state from critical IMM has detected that microprocessor 2 ...

Page 1443: ...Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response Information only no action is required 8107021b 0304ffff Sensor SensorElementName has transitioned to a less severe state from critical IMM has detected that microprocessor 4 has recovered from a QPI Link Error May also be shown as 8107021b0304ffff or 0x8107021b0304ffff Severity Info Serviceable No Auto...

Page 1444: ... less severe state from critical IMM has detected that microprocessor 1 has recovered from a External QPI Link Error May also be shown as 810702211f01ffff or 0x810702211f01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response Information only no action is required 81070221 1f02ffff Sensor Se...

Page 1445: ...y Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response Information only no action is required 81070221 1f04ffff Sensor SensorElementName has transitioned to a less severe state from critical IMM has detected that microprocessor 4 has recovered from a External QPI Link Error May also be shown as 810702211...

Page 1446: ...r SensorElementName has transitioned to a less severe state from critical IOBook2 Mismatch has been removed May also be shown as 810702212c02ffff or 0x810702212c02ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response Information only no action is required 81070301 0301ffff Sensor SensorEleme...

Page 1447: ...0x810703010302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0525 User Response Information only no action is required 81070301 0303ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state The microprocessor 3 temperature has returned to below its spec...

Page 1448: ...x PLAT ID 0525 User Response Information only no action is required 81070301 2c01ffff Sensor SensorElementName has transitioned to a less severe state from non recoverable IMM has detected that the ML2 Card has deasserted an Over temperature condition May also be shown as 810703012c01ffff or 0x810703012c01ffff Severity Info Serviceable no Automatically notify support no Alert Category Critical Tem...

Page 1449: ...recoverable IMM has detected that CPU Mismatch Missing Boot CPU Type Err CPU has deasserted the event May also be shown as 810706072583ffff or 0x810706072583ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0531 User Response Information only no action is required 81070607 2b01ffff Sensor SensorElementName...

Page 1450: ...381ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0531 User Response Information only no action is required 8107060f 2201ffff Sensor SensorElementName has deasserted the transition to non recoverable IMM has detected that the Trusted Platform Module TPM has recovered from the initialization error May als...

Page 1451: ...is required 8108000f 2101ffff Device LogicalDeviceElementName has been added IMM has detected a Trusted Platform Module TPM physical presence switch was asserted May also be shown as 8108000f2101ffff or 0x8108000f2101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0536 User Response Information only no action...

Page 1452: ... Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0803 User Response Information only no action is required 810b010a 1e82ffff Redundancy Lost for RedundancySetElementName has deasserted Fan Redundancy in Zone 2 has been regained May also be shown as 810b010a1e82ffff or 0x810b010a1e82ffff Severity Info Serviceable...

Page 1453: ...84ffff Redundancy Lost for RedundancySetElementName has deasserted Fan Redundancy in Zone 4 has been regained May also be shown as 810b010a1e84ffff or 0x810b010a1e84ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0803 User Response Information only no action is required 810b010a 1e85ffff Redundancy...

Page 1454: ... No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0803 User Response Information only no action is required 810b0208 1381ffff Redundancy Degraded for RedundancySetElementName has deasserted Power Unit is back in redundant state May also be shown as 810b02081381ffff or 0x810b02081381ffff Severity Info Serviceable No Automatically notif...

Page 1455: ...rom Redundancy Degraded or Fully Redundant for RedundancySetElementName has deasserted IMM has detected that Power Supply s capacity met or exceeded the minimum power requirement May also be shown as 810b03091381ffff or 0x810b03091381ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Redundant Power Supply SNMP Trap ID 10 CIM Information Prefix PLAT ID 0807 Us...

Page 1456: ...Severity Info Serviceable No Automatically notify support No Alert Category Critical Redundant Power Supply SNMP Trap ID 9 CIM Information Prefix PLAT ID 0811 User Response Information only no action is required 810b0509 1381ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted IMM has detected that Power Supply s capacity is less than the minimum power requirement ...

Page 1457: ...1 CIM Information Prefix PLAT ID 0811 User Response Information only no action is required 810b050a 1e82ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Fan Zone 2 has regained its redundancy May also be shown as 810b050a1e82ffff or 0x810b050a1e82ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 1...

Page 1458: ...undancy May also be shown as 810b050a1e84ffff or 0x810b050a1e84ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0811 User Response Information only no action is required 810b050a 1e85ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Fan Zone 5 has regained its red...

Page 1459: ...al Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0811 User Response Information only no action is required 816f0007 0301ffff ProcessorElementName has Recovered from IERR IMM has detected that microprocessor 1 recovered from an IERR condition May also be shown as 816f00070301ffff or 0x816f00070301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU S...

Page 1460: ...r 3 recovered from an IERR condition May also be shown as 816f00070303ffff or 0x816f00070303ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0043 User Response Information only no action is required 816f0007 0304ffff ProcessorElementName has Recovered from IERR IMM has detected that microprocessor 4 recover...

Page 1461: ...t Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0085 User Response Information only no action is required 816f0008 0a02ffff PowerSupplyElementName has been removed from container PhysicalPackageElementName IMM has detected that Power Supply 2 has been removed May also be shown as 816f00080a02ffff or 0x816f00080a02ffff Severity Info Serviceable No Automatically notify support No...

Page 1462: ...ntName has been removed from container PhysicalPackageElementName IMM has detected that Power Supply 4 has been removed May also be shown as 816f00080a04ffff or 0x816f00080a04ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0085 User Response Information only no action is required 816f0009 1381ffff PowerSupply...

Page 1463: ...ert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 If drive was intentionally removed no action required 2 Make sure that the drive properly seated 3 If drive is properly seated replace the drive 816f000d 0401ffff The NumericSensorElementName has been removed from unit PhysicalPackageElementName Presence of drive 1 is no longer detected If hard...

Page 1464: ...ory Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 If drive was intentionally removed no action required 2 Make sure that the drive properly seated 3 If drive is properly seated replace the drive 816f000d 0403ffff The NumericSensorElementName has been removed from unit PhysicalPackageElementName Presence of drive 3 is no longer detected If hard drive is...

Page 1465: ...rive was intentionally removed no action required 2 Make sure that the drive properly seated 3 If drive is properly seated replace the drive 816f000d 0405ffff The NumericSensorElementName has been removed from unit PhysicalPackageElementName Presence of drive 5 is no longer detected If hard drive is absent from drive bay a filler is required May also be shown as 816f000d0405ffff or 0x816f000d0405f...

Page 1466: ...sorElementName has been removed from unit PhysicalPackageElementName Presence of drive 7 is no longer detected If hard drive is absent from drive bay a filler is required May also be shown as 816f000d0407ffff or 0x816f000d0407ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1...

Page 1467: ... drive bay a filler is required May also be shown as 816f000d0409ffff or 0x816f000d0409ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 If drive was intentionally removed no action required 2 Make sure that the drive properly seated 3 If drive is properly seated replace the...

Page 1468: ... shown as 816f000d040bffff or 0x816f000d040bffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 If drive was intentionally removed no action required 2 Make sure that the drive properly seated 3 If drive is properly seated replace the drive 816f000d 040cffff The NumericSensorE...

Page 1469: ...000d040dffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 If drive was intentionally removed no action required 2 Make sure that the drive properly seated 3 If drive is properly seated replace the drive 816f000d 040effff The NumericSensorElementName has been removed from uni...

Page 1470: ... Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 If drive was intentionally removed no action required 2 Make sure that the drive properly seated 3 If drive is properly seated replace the drive 816f000f 2201ffff The System ComputerSystemElementName has detected a POST Error deassertion IMM has detected t...

Page 1471: ...uired 816f0021 0b01ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName IMM has detected a fault condition in PCIe slot 1 has been removed May also be shown as 816f00210b01ffff or 0x816f00210b01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Resp...

Page 1472: ...removed May also be shown as 816f00210b03ffff or 0x816f00210b03ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response Information only no action is required 816f0021 0b04ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName IMM has detected a fa...

Page 1473: ...Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response Information only no action is required 816f0021 0b06ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName IMM has detected a fault condition in PCIe slot 6 has been removed May also be shown as 816f00210b06ffff or 0x816f00210b06ffff Severity Info Serviceab...

Page 1474: ...orElementName on system ComputerSystemElementName IMM has detected a fault condition in PCIe slot 8 has been removed May also be shown as 816f00210b08ffff or 0x816f00210b08ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response Information only no action is required 816f0021 0b09ffff Fault con...

Page 1475: ...y Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response Information only no action is required 816f0021 0b0bffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName IMM has detected a fault condition in PCIe slot 11 has been removed May also be shown as 816f002...

Page 1476: ...f Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName IMM has detected a fault condition in PCIe slot 16 has been removed May also be shown as 816f00210b0dffff or 0x816f00210b0dffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response Information only...

Page 1477: ...or 0x816f00210b0fffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response Information only no action is required 816f0021 0b10ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName IMM has detected a fault condition in PCIe slot 19 has been removed...

Page 1478: ...er Response Information only no action is required 816f0021 2582ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName IMM has detected that a fault condition in a PCIe slot has been removed May also be shown as 816f00212582ffff or 0x816f00212582ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap I...

Page 1479: ...as returned to below the critical level May also be shown as 816f01070301ffff or 0x816f01070301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0037 User Response Information only no action is required 816f0107 0302ffff An Over Temperature Condition has been removed on ProcessorElementName The microp...

Page 1480: ...atically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0037 User Response Information only no action is required 816f0107 0304ffff An Over Temperature Condition has been removed on ProcessorElementName The microprocessor 4 temperature has returned to below the critical level May also be shown as 816f01070304ffff or 0x816f01070304ffff Severity I...

Page 1481: ...pplyElementName has returned to OK status IMM has detected that Power Supply 2 has returned to a normal operational status May also be shown as 816f01080a02ffff or 0x816f01080a02ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0087 User Response Information only no action is required 816f0108 0a03ffff Powe...

Page 1482: ...atically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0087 User Response Information only no action is required 816f010c 2581ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error May also be shown as 816f010c2581ffff or 0x816f010c2581ffff...

Page 1483: ...detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 2 in Compute Book 1 May also be shown as 816f010c2b810002 or 0x816f010c2b810002 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no a...

Page 1484: ...b810004 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b810005 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 5 in Co...

Page 1485: ...rrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 7 in Compute Book 1 May also be shown as 816f010c2b810007 or 0x816f010c2b810007 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Respo...

Page 1486: ...or 0x816f010c2b810009 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b81000a Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error o...

Page 1487: ...ID 0139 User Response Information only no action is required 816f010c 2b81000c Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 12 in Compute Book 1 May also be shown as 816f010c2b81000c or 0x816f010c2b81000c Severity Info Serviceable No Automatically notify support No Alert Cat...

Page 1488: ...uncorrectable memory error on DIMM 14 in Compute Book 1 May also be shown as 816f010c2b81000e or 0x816f010c2b81000e Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b81000f Uncorrectable error recovery detected for PhysicalMemoryElementName o...

Page 1489: ...atically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b810011 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 17 in Compute Book 1 May also be shown as 816f010...

Page 1490: ... detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 19 in Compute Book 1 May also be shown as 816f010c2b810013 or 0x816f010c2b810013 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no...

Page 1491: ...10015 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b810016 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 22 in Com...

Page 1492: ...8 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 24 in Compute Book 1 May also be shown as 816f010c2b810018 or 0x816f010c2b810018 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 Use...

Page 1493: ...r 0x816f010c2b820001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b820002 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on...

Page 1494: ...T ID 0139 User Response Information only no action is required 816f010c 2b820004 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 4 in Compute Book 2 May also be shown as 816f010c2b820004 or 0x816f010c2b820004 Severity Info Serviceable No Automatically notify support No Alert Ca...

Page 1495: ...ncorrectable memory error on DIMM 6 in Compute Book 2 May also be shown as 816f010c2b820006 or 0x816f010c2b820006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b820007 Uncorrectable error recovery detected for PhysicalMemoryElementName on ...

Page 1496: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b820009 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 9 in Compute Book 2 May also be shown as 816f01...

Page 1497: ...etected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 11 in Compute Book 2 May also be shown as 816f010c2b82000b or 0x816f010c2b82000b Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no a...

Page 1498: ...b82000d Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b82000e Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 14 in C...

Page 1499: ...rectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 16 in Compute Book 2 May also be shown as 816f010c2b820010 or 0x816f010c2b820010 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Respo...

Page 1500: ... or 0x816f010c2b820012 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b820013 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error ...

Page 1501: ...ID 0139 User Response Information only no action is required 816f010c 2b820015 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 21 in Compute Book 2 May also be shown as 816f010c2b820015 or 0x816f010c2b820015 Severity Info Serviceable No Automatically notify support No Alert Cat...

Page 1502: ...uncorrectable memory error on DIMM 23 in Compute Book 2 May also be shown as 816f010c2b820017 or 0x816f010c2b820017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b820018 Uncorrectable error recovery detected for PhysicalMemoryElementName o...

Page 1503: ...lly notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b830001 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 1 in Compute Book 3 May also be shown as 816f010c2b830...

Page 1504: ... detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 3 in Compute Book 3 May also be shown as 816f010c2b830003 or 0x816f010c2b830003 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no ...

Page 1505: ...30005 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b830006 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 6 in Comp...

Page 1506: ...orrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 8 in Compute Book 3 May also be shown as 816f010c2b830008 or 0x816f010c2b830008 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Resp...

Page 1507: ...r 0x816f010c2b83000a Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b83000b Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on...

Page 1508: ...T ID 0139 User Response Information only no action is required 816f010c 2b83000d Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 13 in Compute Book 3 May also be shown as 816f010c2b83000d or 0x816f010c2b83000d Severity Info Serviceable No Automatically notify support No Alert C...

Page 1509: ...correctable memory error on DIMM 15 in Compute Book 3 May also be shown as 816f010c2b83000f or 0x816f010c2b83000f Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b830010 Uncorrectable error recovery detected for PhysicalMemoryElementName on ...

Page 1510: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b830012 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 18 in Compute Book 3 May also be shown as 816f0...

Page 1511: ...etected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 20 in Compute Book 3 May also be shown as 816f010c2b830014 or 0x816f010c2b830014 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no a...

Page 1512: ...b830016 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b830017 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 23 in C...

Page 1513: ... Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on Compute Book 3 May also be shown as 816f010c2b83ffff or 0x816f010c2b83ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response I...

Page 1514: ... or 0x816f010c2b840002 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b840003 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error ...

Page 1515: ...ID 0139 User Response Information only no action is required 816f010c 2b840005 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 5 in Compute Book 4 May also be shown as 816f010c2b840005 or 0x816f010c2b840005 Severity Info Serviceable No Automatically notify support No Alert Cate...

Page 1516: ...uncorrectable memory error on DIMM 7 in Compute Book 4 May also be shown as 816f010c2b840007 or 0x816f010c2b840007 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b840008 Uncorrectable error recovery detected for PhysicalMemoryElementName on...

Page 1517: ...atically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b84000a Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 10 in Compute Book 4 May also be shown as 816f010...

Page 1518: ... detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 12 in Compute Book 4 May also be shown as 816f010c2b84000c or 0x816f010c2b84000c Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no...

Page 1519: ...4000e Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b84000f Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 15 in Com...

Page 1520: ...orrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 17 in Compute Book 4 May also be shown as 816f010c2b840011 or 0x816f010c2b840011 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Res...

Page 1521: ...r 0x816f010c2b840013 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b840014 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on...

Page 1522: ...T ID 0139 User Response Information only no action is required 816f010c 2b840016 Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported a recovery from an uncorrectable memory error on DIMM 22 in Compute Book 4 May also be shown as 816f010c2b840016 or 0x816f010c2b840016 Severity Info Serviceable No Automatically notify support No Alert C...

Page 1523: ... an uncorrectable memory error on DIMM 24 in Compute Book 4 May also be shown as 816f010c2b840018 or 0x816f010c2b840018 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response Information only no action is required 816f010c 2b84ffff Uncorrectable error recovery detected for PhysicalMemoryElementNa...

Page 1524: ...Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 0401ffff The NumericSensorElementName has been enabled The previously disabled drive 1 has been enabled May also be shown as 816f010d0401ffff or 0x816f010d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard...

Page 1525: ...s been enabled The previously disabled drive 3 has been enabled May also be shown as 816f010d0403ffff or 0x816f010d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 0404ffff The NumericSensorElementName has been enabled The pre...

Page 1526: ...nformation Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 0406ffff The NumericSensorElementName has been enabled The previously disabled drive 6 has been enabled May also be shown as 816f010d0406ffff or 0x816f010d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT...

Page 1527: ...hown as 816f010d0408ffff or 0x816f010d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 0409ffff The NumericSensorElementName has been enabled The previously disabled drive 9 has been enabled May also be shown as 816f010d0409ff...

Page 1528: ...mation only no action is required 816f010d 040bffff The NumericSensorElementName has been enabled The previously disabled drive 11 has been enabled May also be shown as 816f010d040bffff or 0x816f010d040bffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action...

Page 1529: ...040dffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 040effff The NumericSensorElementName has been enabled The previously disabled drive 14 has been enabled May also be shown as 816f010d040effff or 0x816f010d040effff Severity Inf...

Page 1530: ...icSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 1 in Compute Book 1 May also be shown as 816f010d2b810001 or 0x816f010d2b810001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is requ...

Page 1531: ...816f010d2b810003 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b810004 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 4 in Compute Book 1 May also be...

Page 1532: ...CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b810006 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 6 in Compute Book 1 May also be shown as 816f010d2b810006 or 0x816f010d2b810006 Severity Info Serviceable No Automatically notify support No Alert Category Critical...

Page 1533: ...sserted a previous reported fault on the eXFlash DIMM 8 in Compute Book 1 May also be shown as 816f010d2b810008 or 0x816f010d2b810008 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b810009 The NumericSensorElementName has been enabl...

Page 1534: ...ble No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b81000b The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 11 in Compute Book 1 May also be shown as 816f010d2b81000b or 0x816f01...

Page 1535: ...icSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 13 in Compute Book 1 May also be shown as 816f010d2b81000d or 0x816f010d2b81000d Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is req...

Page 1536: ...00f Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b810010 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 16 in Compute Book 1 May also be shown as 81...

Page 1537: ...6f010d 2b810012 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 18 in Compute Book 1 May also be shown as 816f010d2b810012 or 0x816f010d2b810012 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Informat...

Page 1538: ...x816f010d2b810014 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b810015 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 21 in Compute Book 1 May also ...

Page 1539: ...M Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b810017 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 23 in Compute Book 1 May also be shown as 816f010d2b810017 or 0x816f010d2b810017 Severity Info Serviceable No Automatically notify support No Alert Category Critical ...

Page 1540: ...easserted a previous reported fault on the eXFlash DIMM 1 in Compute Book 2 May also be shown as 816f010d2b820001 or 0x816f010d2b820001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b820002 The NumericSensorElementName has been ena...

Page 1541: ...le No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b820004 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 4 in Compute Book 2 May also be shown as 816f010d2b820004 or 0x816f010d...

Page 1542: ...ericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 6 in Compute Book 2 May also be shown as 816f010d2b820006 or 0x816f010d2b820006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is re...

Page 1543: ...8 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b820009 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 9 in Compute Book 2 May also be shown as 816f0...

Page 1544: ...16f010d 2b82000b The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 11 in Compute Book 2 May also be shown as 816f010d2b82000b or 0x816f010d2b82000b Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Informa...

Page 1545: ...816f010d2b82000d Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b82000e The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 14 in Compute Book 2 May also b...

Page 1546: ...CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b820010 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 16 in Compute Book 2 May also be shown as 816f010d2b820010 or 0x816f010d2b820010 Severity Info Serviceable No Automatically notify support No Alert Category Critica...

Page 1547: ...sserted a previous reported fault on the eXFlash DIMM 18 in Compute Book 2 May also be shown as 816f010d2b820012 or 0x816f010d2b820012 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b820013 The NumericSensorElementName has been enab...

Page 1548: ...ble No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b820015 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 21 in Compute Book 2 May also be shown as 816f010d2b820015 or 0x816f01...

Page 1549: ...icSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 23 in Compute Book 2 May also be shown as 816f010d2b820017 or 0x816f010d2b820017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is req...

Page 1550: ...001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b830002 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 2 in Compute Book 3 May also be shown as 816...

Page 1551: ...6f010d 2b830004 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 4 in Compute Book 3 May also be shown as 816f010d2b830004 or 0x816f010d2b830004 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Informati...

Page 1552: ...x816f010d2b830006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b830007 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 7 in Compute Book 3 May also b...

Page 1553: ...M Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b830009 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 9 in Compute Book 3 May also be shown as 816f010d2b830009 or 0x816f010d2b830009 Severity Info Serviceable No Automatically notify support No Alert Category Critical H...

Page 1554: ...asserted a previous reported fault on the eXFlash DIMM 11 in Compute Book 3 May also be shown as 816f010d2b83000b or 0x816f010d2b83000b Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b83000c The NumericSensorElementName has been ena...

Page 1555: ...le No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b83000e The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 14 in Compute Book 3 May also be shown as 816f010d2b83000e or 0x816f010...

Page 1556: ...ricSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 16 in Compute Book 3 May also be shown as 816f010d2b830010 or 0x816f010d2b830010 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is re...

Page 1557: ...2 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b830013 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 19 in Compute Book 3 May also be shown as 816f...

Page 1558: ...16f010d 2b830015 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 21 in Compute Book 3 May also be shown as 816f010d2b830015 or 0x816f010d2b830015 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Informa...

Page 1559: ...816f010d2b830017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b830018 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 24 in Compute Book 3 May also b...

Page 1560: ...CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b840002 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 2 in Compute Book 4 May also be shown as 816f010d2b840002 or 0x816f010d2b840002 Severity Info Serviceable No Automatically notify support No Alert Category Critical...

Page 1561: ...sserted a previous reported fault on the eXFlash DIMM 4 in Compute Book 4 May also be shown as 816f010d2b840004 or 0x816f010d2b840004 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b840005 The NumericSensorElementName has been enabl...

Page 1562: ...ble No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b840007 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 7 in Compute Book 4 May also be shown as 816f010d2b840007 or 0x816f010...

Page 1563: ...icSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 9 in Compute Book 4 May also be shown as 816f010d2b840009 or 0x816f010d2b840009 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is requ...

Page 1564: ...00b Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b84000c The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 12 in Compute Book 4 May also be shown as 81...

Page 1565: ...6f010d 2b84000e The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 14 in Compute Book 4 May also be shown as 816f010d2b84000e or 0x816f010d2b84000e Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Informat...

Page 1566: ...x816f010d2b840010 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b840011 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 17 in Compute Book 4 May also ...

Page 1567: ...M Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b840013 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 19 in Compute Book 4 May also be shown as 816f010d2b840013 or 0x816f010d2b840013 Severity Info Serviceable No Automatically notify support No Alert Category Critical ...

Page 1568: ...asserted a previous reported fault on the eXFlash DIMM 21 in Compute Book 4 May also be shown as 816f010d2b840015 or 0x816f010d2b840015 Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b840016 The NumericSensorElementName has been ena...

Page 1569: ...le No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response Information only no action is required 816f010d 2b840018 The NumericSensorElementName has been enabled The eXFlash Proxy Service deasserted a previous reported fault on the eXFlash DIMM 24 in Compute Book 4 May also be shown as 816f010d2b840018 or 0x816f010...

Page 1570: ...as recovered from a bus timeout The IMM has detected that a system has recovered from a NMI State Bus Timeout May also be shown as 816f01131701ffff or 0x816f01131701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0225 User Response Information only no action is required 816f011b 0701ffff The connector Ph...

Page 1571: ...f011b1f01ffff or 0x816f011b1f01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0267 User Response Information only no action is required 816f0125 2c05ffff ManagedElementName detected as present The IMM has detected the Storage Book is now Present May also be shown as 816f01252c05ffff or 0x816f01252c05fff...

Page 1572: ... ProcessorElementName has Recovered from FRB1 BIST condition IMM has reported that microprocessor 2 has recovered from a FRB1 BIST condition May also be shown as 816f02070302ffff or 0x816f02070302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0045 User Response Information only no action is required 816f0...

Page 1573: ...rviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0045 User Response Information only no action is required 816f0207 2583ffff ProcessorElementName has Recovered from FRB1 BIST condition IMM has reported that a microprocessor has recovered from a FRB1 BIST condition May also be shown as 816f02072583ffff or 0x816f02072583ffff Seve...

Page 1574: ...ure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The predicted failure for Drive 1 no longer exists May also be shown as 816f020d0401ffff or 0x816f020d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is requ...

Page 1575: ...f Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 0404ffff Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The predicted failure for Drive 4 no longer exists May also be shown as 816f020d04...

Page 1576: ...ed 816f020d 0406ffff Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The predicted failure for Drive 6 no longer exists May also be shown as 816f020d0406ffff or 0x816f020d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Informati...

Page 1577: ...816f020d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 0409ffff Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The predicted failure for Drive 9 no longer exists May also be show...

Page 1578: ...PLAT ID 0169 User Response Information only no action is required 816f020d 040bffff Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The predicted failure for Drive 11 no longer exists May also be shown as 816f020d040bffff or 0x816f020d040bffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap I...

Page 1579: ...ure for Drive 13 no longer exists May also be shown as 816f020d040dffff or 0x816f020d040dffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 040effff Failure no longer Predicted on NumericSensorElementName for array ComputerSystemEl...

Page 1580: ...Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b810801 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 1 in Compute Book 1 May also be shown as 816f020d2b810801 o...

Page 1581: ...n NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 3 in Compute Book 1 May also be shown as 816f020d2b810803 or 0x816f020d2b810803 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respons...

Page 1582: ...16f020d2b810805 or 0x816f020d2b810805 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b810806 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previou...

Page 1583: ...ly notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b810808 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 8 in Compute Book 1 May also be ...

Page 1584: ...n NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 10 in Compute Book 1 May also be shown as 816f020d2b81080a or 0x816f020d2b81080a Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respon...

Page 1585: ...6f020d2b81080c or 0x816f020d2b81080c Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b81080d Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous...

Page 1586: ...ally notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b81080f Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 15 in Compute Book 1 May also ...

Page 1587: ... NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 17 in Compute Book 1 May also be shown as 816f020d2b810811 or 0x816f020d2b810811 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respons...

Page 1588: ...16f020d2b810813 or 0x816f020d2b810813 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b810814 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previou...

Page 1589: ...ly notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b810816 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 22 in Compute Book 1 May also be...

Page 1590: ...on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 24 in Compute Book 1 May also be shown as 816f020d2b810818 or 0x816f020d2b810818 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respo...

Page 1591: ...6f020d2b820802 or 0x816f020d2b820802 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b820803 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous...

Page 1592: ...ally notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b820805 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 5 in Compute Book 2 May also b...

Page 1593: ...n NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 7 in Compute Book 2 May also be shown as 816f020d2b820807 or 0x816f020d2b820807 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respons...

Page 1594: ...16f020d2b820809 or 0x816f020d2b820809 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b82080a Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previou...

Page 1595: ...ly notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b82080c Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 12 in Compute Book 2 May also be...

Page 1596: ...on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 14 in Compute Book 2 May also be shown as 816f020d2b82080e or 0x816f020d2b82080e Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respo...

Page 1597: ...6f020d2b820810 or 0x816f020d2b820810 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b820811 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous...

Page 1598: ...ally notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b820813 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 19 in Compute Book 2 May also ...

Page 1599: ... NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 21 in Compute Book 2 May also be shown as 816f020d2b820815 or 0x816f020d2b820815 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respons...

Page 1600: ...16f020d2b820817 or 0x816f020d2b820817 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b820818 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previou...

Page 1601: ...ly notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b830802 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 2 in Compute Book 3 May also be ...

Page 1602: ...on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 4 in Compute Book 3 May also be shown as 816f020d2b830804 or 0x816f020d2b830804 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respon...

Page 1603: ...6f020d2b830806 or 0x816f020d2b830806 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b830807 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous...

Page 1604: ...ally notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b830809 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 9 in Compute Book 3 May also b...

Page 1605: ... NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 11 in Compute Book 3 May also be shown as 816f020d2b83080b or 0x816f020d2b83080b Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respons...

Page 1606: ...16f020d2b83080d or 0x816f020d2b83080d Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b83080e Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previou...

Page 1607: ...ly notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b830810 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 16 in Compute Book 3 May also be...

Page 1608: ...on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 18 in Compute Book 3 May also be shown as 816f020d2b830812 or 0x816f020d2b830812 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respo...

Page 1609: ...6f020d2b830814 or 0x816f020d2b830814 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b830815 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous...

Page 1610: ...ally notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b830817 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 23 in Compute Book 3 May also ...

Page 1611: ...n NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 1 in Compute Book 4 May also be shown as 816f020d2b840801 or 0x816f020d2b840801 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respons...

Page 1612: ...16f020d2b840803 or 0x816f020d2b840803 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b840804 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previou...

Page 1613: ...ly notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b840806 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 6 in Compute Book 4 May also be ...

Page 1614: ...on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 8 in Compute Book 4 May also be shown as 816f020d2b840808 or 0x816f020d2b840808 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respon...

Page 1615: ...6f020d2b84080a or 0x816f020d2b84080a Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b84080b Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous...

Page 1616: ...ally notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b84080d Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 13 in Compute Book 4 May also ...

Page 1617: ... NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 15 in Compute Book 4 May also be shown as 816f020d2b84080f or 0x816f020d2b84080f Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respons...

Page 1618: ...16f020d2b840811 or 0x816f020d2b840811 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b840812 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previou...

Page 1619: ...ly notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f020d 2b840814 Failure no longer Predicted on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 20 in Compute Book 4 May also be...

Page 1620: ...on NumericSensorElementName for array ComputerSystemElementName The eXFlash Proxy Service deasserted a previous reported predicted failure for eXFlash DIMM 22 in Compute Book 4 May also be shown as 816f020d2b840816 or 0x816f020d2b840816 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Respo...

Page 1621: ...y also be shown as 816f020d2b840818 or 0x816f020d2b840818 Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response Information only no action is required 816f0308 0a01ffff PowerSupplyElementName has returned to a Normal Input State IMM has detected that the input power for Power Supply 1 h...

Page 1622: ... is required 816f0308 0a03ffff PowerSupplyElementName has returned to a Normal Input State IMM has detected that the input power for Power Supply 3 has been restored May also be shown as 816f03080a03ffff or 0x816f03080a03ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0099 User Response Information only no ac...

Page 1623: ...x816f030c2b810001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b810002 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 2 in Compute Book 1 has rec...

Page 1624: ...x PLAT ID 0137 User Response Information only no action is required 816f030c 2b810004 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 4 in Compute Book 1 has recovered May also be shown as 816f030c2b810004 or 0x816f030c2b810004 Severity Info Serviceable No Automatically notify support No Alert Category Crit...

Page 1625: ...ing boot on DIMM 6 in Compute Book 1 has recovered May also be shown as 816f030c2b810006 or 0x816f030c2b810006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b810007 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName...

Page 1626: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b810009 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 9 in Compute Book 1 has recovered May also be shown as 816f030c2b810009 or 0x...

Page 1627: ...icalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 11 in Compute Book 1 has recovered May also be shown as 816f030c2b81000b or 0x816f030c2b81000b Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is...

Page 1628: ...b81000d Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b81000e Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 14 in Compute Book 1 has recovered Ma...

Page 1629: ...10 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 16 in Compute Book 1 has recovered May also be shown as 816f030c2b810010 or 0x816f030c2b810010 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Info...

Page 1630: ... or 0x816f030c2b810012 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b810013 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 19 in Compute Book 1 h...

Page 1631: ...PLAT ID 0137 User Response Information only no action is required 816f030c 2b810015 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 21 in Compute Book 1 has recovered May also be shown as 816f030c2b810015 or 0x816f030c2b810015 Severity Info Serviceable No Automatically notify support No Alert Category Criti...

Page 1632: ...ring boot on DIMM 23 in Compute Book 1 has recovered May also be shown as 816f030c2b810017 or 0x816f030c2b810017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b810018 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementNa...

Page 1633: ...lly notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b820001 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 1 in Compute Book 2 has recovered May also be shown as 816f030c2b820001 or 0x816f030...

Page 1634: ...ysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 3 in Compute Book 2 has recovered May also be shown as 816f030c2b820003 or 0x816f030c2b820003 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action i...

Page 1635: ...20005 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b820006 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 6 in Compute Book 2 has recovered May a...

Page 1636: ...0008 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 8 in Compute Book 2 has recovered May also be shown as 816f030c2b820008 or 0x816f030c2b820008 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Inf...

Page 1637: ...r 0x816f030c2b82000a Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b82000b Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 11 in Compute Book 2 has...

Page 1638: ...x PLAT ID 0137 User Response Information only no action is required 816f030c 2b82000d Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 13 in Compute Book 2 has recovered May also be shown as 816f030c2b82000d or 0x816f030c2b82000d Severity Info Serviceable No Automatically notify support No Alert Category Cri...

Page 1639: ...ng boot on DIMM 15 in Compute Book 2 has recovered May also be shown as 816f030c2b82000f or 0x816f030c2b82000f Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b820010 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName...

Page 1640: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b820012 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 18 in Compute Book 2 has recovered May also be shown as 816f030c2b820012 or 0...

Page 1641: ...icalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 20 in Compute Book 2 has recovered May also be shown as 816f030c2b820014 or 0x816f030c2b820014 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is...

Page 1642: ...b820016 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b820017 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 23 in Compute Book 2 has recovered Ma...

Page 1643: ...2b82ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on Compute Book 2 has recovered May also be shown as 816f030c2b82ffff or 0x816f030c2b82ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Informati...

Page 1644: ... or 0x816f030c2b830002 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b830003 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 3 in Compute Book 3 ha...

Page 1645: ...PLAT ID 0137 User Response Information only no action is required 816f030c 2b830005 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 5 in Compute Book 3 has recovered May also be shown as 816f030c2b830005 or 0x816f030c2b830005 Severity Info Serviceable No Automatically notify support No Alert Category Critic...

Page 1646: ...ring boot on DIMM 7 in Compute Book 3 has recovered May also be shown as 816f030c2b830007 or 0x816f030c2b830007 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b830008 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementNam...

Page 1647: ...atically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b83000a Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 10 in Compute Book 3 has recovered May also be shown as 816f030c2b83000a or 0x8...

Page 1648: ...ysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 12 in Compute Book 3 has recovered May also be shown as 816f030c2b83000c or 0x816f030c2b83000c Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action ...

Page 1649: ...3000e Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b83000f Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 15 in Compute Book 3 has recovered May ...

Page 1650: ...0011 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 17 in Compute Book 3 has recovered May also be shown as 816f030c2b830011 or 0x816f030c2b830011 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response In...

Page 1651: ...r 0x816f030c2b830013 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b830014 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 20 in Compute Book 3 has...

Page 1652: ...x PLAT ID 0137 User Response Information only no action is required 816f030c 2b830016 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 22 in Compute Book 3 has recovered May also be shown as 816f030c2b830016 or 0x816f030c2b830016 Severity Info Serviceable No Automatically notify support No Alert Category Cri...

Page 1653: ...d during boot on DIMM 24 in Compute Book 3 has recovered May also be shown as 816f030c2b830018 or 0x816f030c2b830018 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b83ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryEleme...

Page 1654: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b840002 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 2 in Compute Book 4 has recovered May also be shown as 816f030c2b840002 or 0x...

Page 1655: ...sicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 4 in Compute Book 4 has recovered May also be shown as 816f030c2b840004 or 0x816f030c2b840004 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is...

Page 1656: ...b840006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b840007 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 7 in Compute Book 4 has recovered May...

Page 1657: ...09 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 9 in Compute Book 4 has recovered May also be shown as 816f030c2b840009 or 0x816f030c2b840009 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Infor...

Page 1658: ... or 0x816f030c2b84000b Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b84000c Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 12 in Compute Book 4 h...

Page 1659: ...PLAT ID 0137 User Response Information only no action is required 816f030c 2b84000e Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 14 in Compute Book 4 has recovered May also be shown as 816f030c2b84000e or 0x816f030c2b84000e Severity Info Serviceable No Automatically notify support No Alert Category Criti...

Page 1660: ...ring boot on DIMM 16 in Compute Book 4 has recovered May also be shown as 816f030c2b840010 or 0x816f030c2b840010 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b840011 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementNa...

Page 1661: ...atically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b840013 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 19 in Compute Book 4 has recovered May also be shown as 816f030c2b840013 or 0x8...

Page 1662: ...ysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 21 in Compute Book 4 has recovered May also be shown as 816f030c2b840015 or 0x816f030c2b840015 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action ...

Page 1663: ...40017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response Information only no action is required 816f030c 2b840018 Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered A Memory POST failure detected during boot on DIMM 24 in Compute Book 4 has recovered May ...

Page 1664: ...refix PLAT ID 0137 User Response Information only no action is required 816f030d 0400ffff Hot spare disabled for ComputerSystemElementName A hot spare drive is not available May also be shown as 816f030d0400ffff or 0x816f030d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response Information on...

Page 1665: ...30d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response Information only no action required 816f030d 0403ffff Hot spare disabled for ComputerSystemElementName A hot spare drive is not available May also be shown as 816f030d0403ffff or 0x816f030d0403ffff Severity Info Serviceable No Automatic...

Page 1666: ...only no action required 816f030d 0405ffff Hot spare disabled for ComputerSystemElementName A hot spare drive is not available May also be shown as 816f030d0405ffff or 0x816f030d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response Information only no action required 816f030d 0406ffff Hot spar...

Page 1667: ...Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response Information only no action required 816f030d 0408ffff Hot spare disabled for ComputerSystemElementName A hot spare drive is not available May also be shown as 816f030d0408ffff or 0x816f030d0408ffff Severity Info Serviceable No Automatically notify support N...

Page 1668: ...6f030d 040affff Hot spare disabled for ComputerSystemElementName A hot spare drive is not available May also be shown as 816f030d040affff or 0x816f030d040affff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response Information only no action required 816f030d 040bffff Hot spare disabled for ComputerSys...

Page 1669: ...le No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response Information only no action required 816f030d 040dffff Hot spare disabled for ComputerSystemElementName A hot spare drive is not available May also be shown as 816f030d040dffff or 0x816f030d040dffff Severity Info Serviceable No Automatically notify support No Alert Catego...

Page 1670: ...r ComputerSystemElementName A hot spare drive is not available May also be shown as 816f030d040fffff or 0x816f030d040fffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response Information only no action required 816f0313 1701ffff System ComputerSystemElementName has recovered from an NMI IMM has dete...

Page 1671: ...able No Automatically notify support No Alert Category Critical Hardware Incompatibility SNMP Trap ID 36 CIM Information Prefix PLAT ID 0443 User Response Information only no action is required 816f040c 2581ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory has been Enabled May also be shown as 816f040c2581ffff or 0x816f040c2581ffff Severity Info Ser...

Page 1672: ...MemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 2 in Compute Book 1 has been Enabled May also be shown as 816f040c2b810002 or 0x816f040c2b810002 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b810003 ...

Page 1673: ...ble No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b810005 PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 5 in Compute Book 1 has been Enabled May also be shown as 816f040c2b810005 or 0x816f040c2b810005 Severity Info ...

Page 1674: ...mentName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 7 in Compute Book 1 has been Enabled May also be shown as 816f040c2b810007 or 0x816f040c2b810007 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b810008 PhysicalM...

Page 1675: ...notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b81000a PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 10 in Compute Book 1 has been Enabled May also be shown as 816f040c2b81000a or 0x816f040c2b81000a Severity Info Serviceable No Autom...

Page 1676: ...ryElementName IMM has reported that Memory on DIMM 12 in Compute Book 1 has been Enabled May also be shown as 816f040c2b81000c or 0x816f040c2b81000c Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b81000d PhysicalMemoryElementName Enabled on Subsy...

Page 1677: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b81000f PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 15 in Compute Book 1 has been Enabled May also be shown as 816f040c2b81000f or 0x816f040c2b81000f Severity Info Serviceable No Automatically notif...

Page 1678: ...ryElementName IMM has reported that Memory on DIMM 17 in Compute Book 1 has been Enabled May also be shown as 816f040c2b810011 or 0x816f040c2b810011 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b810012 PhysicalMemoryElementName Enabled on Subsy...

Page 1679: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b810014 PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 20 in Compute Book 1 has been Enabled May also be shown as 816f040c2b810014 or 0x816f040c2b810014 Severity Info Serviceable No Automatically notif...

Page 1680: ...ryElementName IMM has reported that Memory on DIMM 22 in Compute Book 1 has been Enabled May also be shown as 816f040c2b810016 or 0x816f040c2b810016 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b810017 PhysicalMemoryElementName Enabled on Subsy...

Page 1681: ...pport No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b81ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on Compute Book 1 has been Enabled May also be shown as 816f040c2b81ffff or 0x816f040c2b81ffff Severity Info Serviceable No Automatically notify supp...

Page 1682: ...oryElementName IMM has reported that Memory on DIMM 2 in Compute Book 2 has been Enabled May also be shown as 816f040c2b820002 or 0x816f040c2b820002 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b820003 PhysicalMemoryElementName Enabled on Subsy...

Page 1683: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b820005 PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 5 in Compute Book 2 has been Enabled May also be shown as 816f040c2b820005 or 0x816f040c2b820005 Severity Info Serviceable No Automatically notify...

Page 1684: ...oryElementName IMM has reported that Memory on DIMM 7 in Compute Book 2 has been Enabled May also be shown as 816f040c2b820007 or 0x816f040c2b820007 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b820008 PhysicalMemoryElementName Enabled on Subsy...

Page 1685: ...No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b82000a PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 10 in Compute Book 2 has been Enabled May also be shown as 816f040c2b82000a or 0x816f040c2b82000a Severity Info Serviceable No Automatically notify...

Page 1686: ...ryElementName IMM has reported that Memory on DIMM 12 in Compute Book 2 has been Enabled May also be shown as 816f040c2b82000c or 0x816f040c2b82000c Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b82000d PhysicalMemoryElementName Enabled on Subsy...

Page 1687: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b82000f PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 15 in Compute Book 2 has been Enabled May also be shown as 816f040c2b82000f or 0x816f040c2b82000f Severity Info Serviceable No Automatically notif...

Page 1688: ...ryElementName IMM has reported that Memory on DIMM 17 in Compute Book 2 has been Enabled May also be shown as 816f040c2b820011 or 0x816f040c2b820011 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b820012 PhysicalMemoryElementName Enabled on Subsy...

Page 1689: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b820014 PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 20 in Compute Book 2 has been Enabled May also be shown as 816f040c2b820014 or 0x816f040c2b820014 Severity Info Serviceable No Automatically notif...

Page 1690: ...ryElementName IMM has reported that Memory on DIMM 22 in Compute Book 2 has been Enabled May also be shown as 816f040c2b820016 or 0x816f040c2b820016 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b820017 PhysicalMemoryElementName Enabled on Subsy...

Page 1691: ...pport No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b82ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on Compute Book 2 has been Enabled May also be shown as 816f040c2b82ffff or 0x816f040c2b82ffff Severity Info Serviceable No Automatically notify supp...

Page 1692: ...oryElementName IMM has reported that Memory on DIMM 2 in Compute Book 3 has been Enabled May also be shown as 816f040c2b830002 or 0x816f040c2b830002 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b830003 PhysicalMemoryElementName Enabled on Subsy...

Page 1693: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b830005 PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 5 in Compute Book 3 has been Enabled May also be shown as 816f040c2b830005 or 0x816f040c2b830005 Severity Info Serviceable No Automatically notify...

Page 1694: ...oryElementName IMM has reported that Memory on DIMM 7 in Compute Book 3 has been Enabled May also be shown as 816f040c2b830007 or 0x816f040c2b830007 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b830008 PhysicalMemoryElementName Enabled on Subsy...

Page 1695: ...No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b83000a PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 10 in Compute Book 3 has been Enabled May also be shown as 816f040c2b83000a or 0x816f040c2b83000a Severity Info Serviceable No Automatically notify...

Page 1696: ...ryElementName IMM has reported that Memory on DIMM 12 in Compute Book 3 has been Enabled May also be shown as 816f040c2b83000c or 0x816f040c2b83000c Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b83000d PhysicalMemoryElementName Enabled on Subsy...

Page 1697: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b83000f PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 15 in Compute Book 3 has been Enabled May also be shown as 816f040c2b83000f or 0x816f040c2b83000f Severity Info Serviceable No Automatically notif...

Page 1698: ...ryElementName IMM has reported that Memory on DIMM 17 in Compute Book 3 has been Enabled May also be shown as 816f040c2b830011 or 0x816f040c2b830011 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b830012 PhysicalMemoryElementName Enabled on Subsy...

Page 1699: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b830014 PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 20 in Compute Book 3 has been Enabled May also be shown as 816f040c2b830014 or 0x816f040c2b830014 Severity Info Serviceable No Automatically notif...

Page 1700: ...ryElementName IMM has reported that Memory on DIMM 22 in Compute Book 3 has been Enabled May also be shown as 816f040c2b830016 or 0x816f040c2b830016 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b830017 PhysicalMemoryElementName Enabled on Subsy...

Page 1701: ...pport No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b83ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on Compute Book 3 has been Enabled May also be shown as 816f040c2b83ffff or 0x816f040c2b83ffff Severity Info Serviceable No Automatically notify supp...

Page 1702: ...oryElementName IMM has reported that Memory on DIMM 2 in Compute Book 4 has been Enabled May also be shown as 816f040c2b840002 or 0x816f040c2b840002 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b840003 PhysicalMemoryElementName Enabled on Subsy...

Page 1703: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b840005 PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 5 in Compute Book 4 has been Enabled May also be shown as 816f040c2b840005 or 0x816f040c2b840005 Severity Info Serviceable No Automatically notify...

Page 1704: ...oryElementName IMM has reported that Memory on DIMM 7 in Compute Book 4 has been Enabled May also be shown as 816f040c2b840007 or 0x816f040c2b840007 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b840008 PhysicalMemoryElementName Enabled on Subsy...

Page 1705: ...No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b84000a PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 10 in Compute Book 4 has been Enabled May also be shown as 816f040c2b84000a or 0x816f040c2b84000a Severity Info Serviceable No Automatically notify...

Page 1706: ...ryElementName IMM has reported that Memory on DIMM 12 in Compute Book 4 has been Enabled May also be shown as 816f040c2b84000c or 0x816f040c2b84000c Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b84000d PhysicalMemoryElementName Enabled on Subsy...

Page 1707: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b84000f PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 15 in Compute Book 4 has been Enabled May also be shown as 816f040c2b84000f or 0x816f040c2b84000f Severity Info Serviceable No Automatically notif...

Page 1708: ...ryElementName IMM has reported that Memory on DIMM 17 in Compute Book 4 has been Enabled May also be shown as 816f040c2b840011 or 0x816f040c2b840011 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b840012 PhysicalMemoryElementName Enabled on Subsy...

Page 1709: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b840014 PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on DIMM 20 in Compute Book 4 has been Enabled May also be shown as 816f040c2b840014 or 0x816f040c2b840014 Severity Info Serviceable No Automatically notif...

Page 1710: ...ryElementName IMM has reported that Memory on DIMM 22 in Compute Book 4 has been Enabled May also be shown as 816f040c2b840016 or 0x816f040c2b840016 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b840017 PhysicalMemoryElementName Enabled on Subsy...

Page 1711: ...pport No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response Information only no action is required 816f040c 2b84ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName IMM has reported that Memory on Compute Book 4 has been Enabled May also be shown as 816f040c2b84ffff or 0x816f040c2b84ffff Severity Info Serviceable No Automatically notify supp...

Page 1712: ...on Mismatch Microprocessor 2 has Recovered from a Microprocessor Configuration Mismatch May also be shown as 816f05070302ffff or 0x816f05070302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0063 User Response Information only no action is required 816f0507 0303ffff ProcessorElementName has Recovered from ...

Page 1713: ... Prefix PLAT ID 0063 User Response Information only no action is required 816f0507 2583ffff ProcessorElementName has Recovered from a Configuration Mismatch One or more microprocessors have recovered from a microprocessor configuration mismatch May also be shown as 816f05072583ffff or 0x816f05072583ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP T...

Page 1714: ...ute Book 1 Logging Limit has been Removed May also be shown as 816f050c2b810001 or 0x816f050c2b810001 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b810002 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElemen...

Page 1715: ...matically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b810004 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 4 in Compute Book 1 Logging Limit has been Removed May also be shown as 816f050c2b810004...

Page 1716: ...oved for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 6 in Compute Book 1 Logging Limit has been Removed May also be shown as 816f050c2b810006 or 0x816f050c2b810006 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no actio...

Page 1717: ...810008 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b810009 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 9 in Compute Book 1 Logging Limit has been Remov...

Page 1718: ... Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 11 in Compute Book 1 Logging Limit has been Removed May also be shown as 816f050c2b81000b or 0x816f050c2b81000b Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response...

Page 1719: ...or 0x816f050c2b81000d Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b81000e Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 14 in Compute Book 1 Logging Limi...

Page 1720: ... PLAT ID 0145 User Response Information only no action is required 816f050c 2b810010 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 16 in Compute Book 1 Logging Limit has been Removed May also be shown as 816f050c2b810010 or 0x816f050c2b810010 Severity Info Serviceable No Automatically notify support No Alert Categ...

Page 1721: ...MM 18 in Compute Book 1 Logging Limit has been Removed May also be shown as 816f050c2b810012 or 0x816f050c2b810012 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b810013 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem...

Page 1722: ...omatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b810015 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 21 in Compute Book 1 Logging Limit has been Removed May also be shown as 816f050c2b8100...

Page 1723: ...ed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 23 in Compute Book 1 Logging Limit has been Removed May also be shown as 816f050c2b810017 or 0x816f050c2b810017 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action...

Page 1724: ...ff Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b820001 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 1 in Compute Book 2 Logging Limit has been Removed M...

Page 1725: ...Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 3 in Compute Book 2 Logging Limit has been Removed May also be shown as 816f050c2b820003 or 0x816f050c2b820003 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response I...

Page 1726: ... or 0x816f050c2b820005 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b820006 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 6 in Compute Book 2 Logging Limi...

Page 1727: ...PLAT ID 0145 User Response Information only no action is required 816f050c 2b820008 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 8 in Compute Book 2 Logging Limit has been Removed May also be shown as 816f050c2b820008 or 0x816f050c2b820008 Severity Info Serviceable No Automatically notify support No Alert Categor...

Page 1728: ...IMM 10 in Compute Book 2 Logging Limit has been Removed May also be shown as 816f050c2b82000a or 0x816f050c2b82000a Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b82000b Memory Logging Limit Removed for PhysicalMemoryElementName on Subsyste...

Page 1729: ...matically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b82000d Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 13 in Compute Book 2 Logging Limit has been Removed May also be shown as 816f050c2b82000...

Page 1730: ...oved for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 15 in Compute Book 2 Logging Limit has been Removed May also be shown as 816f050c2b82000f or 0x816f050c2b82000f Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no acti...

Page 1731: ...820011 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b820012 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 18 in Compute Book 2 Logging Limit has been Remo...

Page 1732: ... Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 20 in Compute Book 2 Logging Limit has been Removed May also be shown as 816f050c2b820014 or 0x816f050c2b820014 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response...

Page 1733: ...or 0x816f050c2b820016 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b820017 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 23 in Compute Book 2 Logging Limi...

Page 1734: ...Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b82ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on Compute Book 2 Logging Limit has been Removed May also be shown as 816f050c2b82ffff or 0x816f050c2b82ffff Severity Info Serviceable No Automatically notify support No Alert Category W...

Page 1735: ...MM 2 in Compute Book 3 Logging Limit has been Removed May also be shown as 816f050c2b830002 or 0x816f050c2b830002 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b830003 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem ...

Page 1736: ...omatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b830005 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 5 in Compute Book 3 Logging Limit has been Removed May also be shown as 816f050c2b83000...

Page 1737: ...ved for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 7 in Compute Book 3 Logging Limit has been Removed May also be shown as 816f050c2b830007 or 0x816f050c2b830007 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action...

Page 1738: ...b830009 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b83000a Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 10 in Compute Book 3 Logging Limit has been Rem...

Page 1739: ...emory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 12 in Compute Book 3 Logging Limit has been Removed May also be shown as 816f050c2b83000c or 0x816f050c2b83000c Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response I...

Page 1740: ... or 0x816f050c2b83000e Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b83000f Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 15 in Compute Book 3 Logging Lim...

Page 1741: ...PLAT ID 0145 User Response Information only no action is required 816f050c 2b830011 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 17 in Compute Book 3 Logging Limit has been Removed May also be shown as 816f050c2b830011 or 0x816f050c2b830011 Severity Info Serviceable No Automatically notify support No Alert Catego...

Page 1742: ...IMM 19 in Compute Book 3 Logging Limit has been Removed May also be shown as 816f050c2b830013 or 0x816f050c2b830013 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b830014 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsyste...

Page 1743: ...matically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b830016 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 22 in Compute Book 3 Logging Limit has been Removed May also be shown as 816f050c2b83001...

Page 1744: ...t Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 24 in Compute Book 3 Logging Limit has been Removed May also be shown as 816f050c2b830018 or 0x816f050c2b830018 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no...

Page 1745: ...840001 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b840002 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 2 in Compute Book 4 Logging Limit has been Remov...

Page 1746: ... Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 4 in Compute Book 4 Logging Limit has been Removed May also be shown as 816f050c2b840004 or 0x816f050c2b840004 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response ...

Page 1747: ...or 0x816f050c2b840006 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b840007 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 7 in Compute Book 4 Logging Limit...

Page 1748: ... PLAT ID 0145 User Response Information only no action is required 816f050c 2b840009 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 9 in Compute Book 4 Logging Limit has been Removed May also be shown as 816f050c2b840009 or 0x816f050c2b840009 Severity Info Serviceable No Automatically notify support No Alert Catego...

Page 1749: ...MM 11 in Compute Book 4 Logging Limit has been Removed May also be shown as 816f050c2b84000b or 0x816f050c2b84000b Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b84000c Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem...

Page 1750: ...omatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b84000e Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 14 in Compute Book 4 Logging Limit has been Removed May also be shown as 816f050c2b8400...

Page 1751: ...ed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 16 in Compute Book 4 Logging Limit has been Removed May also be shown as 816f050c2b840010 or 0x816f050c2b840010 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action...

Page 1752: ...b840012 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b840013 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 19 in Compute Book 4 Logging Limit has been Rem...

Page 1753: ...emory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 21 in Compute Book 4 Logging Limit has been Removed May also be shown as 816f050c2b840015 or 0x816f050c2b840015 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response I...

Page 1754: ... or 0x816f050c2b840017 Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response Information only no action is required 816f050c 2b840018 Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName IMM has reported that the Memory on DIMM 24 in Compute Book 4 Logging Lim...

Page 1755: ...sponse Information only no action is required 816f050d 0400ffff Critical Array ComputerSystemElementName has deasserted The RAID array Drive 0 is no longer in a critical condition May also be shown as 816f050d0400ffff or 0x816f050d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Res...

Page 1756: ...0d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response Information only no action is required 816f050d 0403ffff Critical Array ComputerSystemElementName has deasserted The RAID array Drive 3 is no longer in a critical condition May also be shown as 816f050d0403ffff or 0x816f050...

Page 1757: ...equired 816f050d 0405ffff Critical Array ComputerSystemElementName has deasserted The RAID array Drive 5 is no longer in a critical condition May also be shown as 816f050d0405ffff or 0x816f050d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response Information only no action is re...

Page 1758: ...Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response Information only no action is required 816f050d 0408ffff Critical Array ComputerSystemElementName has deasserted The RAID array Drive 8 is no longer in a critical condition May also be shown as 816f050d0408ffff or 0x816f050d0408ffff Severity Info S...

Page 1759: ...ritical Array ComputerSystemElementName has deasserted The RAID array Drive 10 is no longer in a critical condition May also be shown as 816f050d040affff or 0x816f050d040affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response Information only no action is required 816f050d 040bffff C...

Page 1760: ...Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response Information only no action is required 816f050d 040dffff Critical Array ComputerSystemElementName has deasserted The RAID array Drive 13 is no longer in a critical condition May also be shown as 816f050d040dffff or 0x816f050d040dffff Severity Info Serviceable No ...

Page 1761: ...e has deasserted The RAID array Drive 15 is no longer in a critical condition May also be shown as 816f050d040fffff or 0x816f050d040fffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response Information only no action is required 816f0607 0301ffff An SM BIOS Uncorrectable CPU complex er...

Page 1762: ...tomatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0817 User Response Information only no action is required 816f0607 0303ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has deasserted An SM BIOS uncorrectable CPU complex error has been deasserted for microprocessor 3 May also be shown as 816f06070303ffff or 0x816f06070...

Page 1763: ... is required 816f0607 2583ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has deasserted SM BIOS Uncorrectable CPU complex error has deasserted May also be shown as 816f06072583ffff or 0x816f06072583ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0817 User Response Information only...

Page 1764: ...ceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response Information only no action is required 816f060d 0401ffff Array in system ComputerSystemElementName has been restored IMM has detected that a Failed Array Drive 1 has been Restored May also be shown as 816f060d0401ffff or 0x816f060d0401ffff Severity Info...

Page 1765: ...ay in system ComputerSystemElementName has been restored IMM has detected that a Failed Array Drive 3 has been Restored May also be shown as 816f060d0403ffff or 0x816f060d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response Information only no action is required 816f060d 0404ff...

Page 1766: ...Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response Information only no action is required 816f060d 0406ffff Array in system ComputerSystemElementName has been restored IMM has detected that a Failed Array Drive 6 has been Restored May also be shown as 816f060d0406ffff or 0x816f060d0406ffff Severity Info Serviceab...

Page 1767: ...ystemElementName has been restored IMM has detected that a Failed Array Drive 8 has been Restored May also be shown as 816f060d0408ffff or 0x816f060d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response Information only no action is required 816f060d 0409ffff Array in system Com...

Page 1768: ...ert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response Information only no action is required 816f060d 040bffff Array in system ComputerSystemElementName has been restored IMM has detected that a Failed Array Drive 11 has been Restored May also be shown as 816f060d040bffff or 0x816f060d040bffff Severity Info Serviceable No Automatically notify suppor...

Page 1769: ...been restored IMM has detected that a Failed Array Drive 13 has been Restored May also be shown as 816f060d040dffff or 0x816f060d040dffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response Information only no action is required 816f060d 040effff Array in system ComputerSystemElementNa...

Page 1770: ...ID 5 CIM Information Prefix PLAT ID 0177 User Response Information only no action is required 816f0707 0301ffff ProcessorElementName in slot SlotElementName has been removed IMM has detected that microprocessor 1 has been removed May also be shown as 816f07070301ffff or 0x816f07070301ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Info...

Page 1771: ...Memory configuration error has recovered May also be shown as 816f070c2b810001 or 0x816f070c2b810001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b810002 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has...

Page 1772: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b810004 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 4 in Compute Book 1 a Memory configuration error has recovered May also be shown as 816f070c2b81...

Page 1773: ...ysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 6 in Compute Book 1 a Memory configuration error has recovered May also be shown as 816f070c2b810006 or 0x816f070c2b810006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no acti...

Page 1774: ...b810008 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b810009 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 9 in Compute Book 1 a Memory configuration error has rec...

Page 1775: ...nfiguration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 11 in Compute Book 1 a Memory configuration error has recovered May also be shown as 816f070c2b81000b or 0x816f070c2b81000b Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response...

Page 1776: ... or 0x816f070c2b81000d Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b81000e Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 14 in Compute Book 1 a Memory configurati...

Page 1777: ...T ID 0127 User Response Information only no action is required 816f070c 2b810010 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 16 in Compute Book 1 a Memory configuration error has recovered May also be shown as 816f070c2b810010 or 0x816f070c2b810010 Severity Info Serviceable No Automatically notify support No Alert Categor...

Page 1778: ...ute Book 1 a Memory configuration error has recovered May also be shown as 816f070c2b810012 or 0x816f070c2b810012 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b810013 Configuration error for PhysicalMemoryElementName on Subsystem MemoryEl...

Page 1779: ...atically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b810015 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 21 in Compute Book 1 a Memory configuration error has recovered May also be shown as 816f070c2b810...

Page 1780: ...hysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 23 in Compute Book 1 a Memory configuration error has recovered May also be shown as 816f070c2b810017 or 0x816f070c2b810017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no ac...

Page 1781: ... Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b820001 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 1 in Compute Book 2 a Memory configuration error has recovered ...

Page 1782: ...Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 3 in Compute Book 2 a Memory configuration error has recovered May also be shown as 816f070c2b820003 or 0x816f070c2b820003 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Respons...

Page 1783: ...r 0x816f070c2b820005 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b820006 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 6 in Compute Book 2 a Memory configuration ...

Page 1784: ...AT ID 0127 User Response Information only no action is required 816f070c 2b820008 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 8 in Compute Book 2 a Memory configuration error has recovered May also be shown as 816f070c2b820008 or 0x816f070c2b820008 Severity Info Serviceable No Automatically notify support No Alert Categor...

Page 1785: ...e Book 2 a Memory configuration error has recovered May also be shown as 816f070c2b82000a or 0x816f070c2b82000a Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b82000b Configuration error for PhysicalMemoryElementName on Subsystem MemoryElem...

Page 1786: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b82000d Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 13 in Compute Book 2 a Memory configuration error has recovered May also be shown as 816f070c2b8...

Page 1787: ...sicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 15 in Compute Book 2 a Memory configuration error has recovered May also be shown as 816f070c2b82000f or 0x816f070c2b82000f Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no acti...

Page 1788: ...b820011 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b820012 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 18 in Compute Book 2 a Memory configuration error has re...

Page 1789: ...nfiguration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 20 in Compute Book 2 a Memory configuration error has recovered May also be shown as 816f070c2b820014 or 0x816f070c2b820014 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response...

Page 1790: ... or 0x816f070c2b820016 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b820017 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 23 in Compute Book 2 a Memory configurati...

Page 1791: ...x PLAT ID 0127 User Response Information only no action is required 816f070c 2b82ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on Compute Book 2 a Memory configuration error has recovered May also be shown as 816f070c2b82ffff or 0x816f070c2b82ffff Severity Info Serviceable No Automatically notify support No Alert Category Crit...

Page 1792: ...ute Book 3 a Memory configuration error has recovered May also be shown as 816f070c2b830002 or 0x816f070c2b830002 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b830003 Configuration error for PhysicalMemoryElementName on Subsystem MemoryEl...

Page 1793: ...atically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b830005 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 5 in Compute Book 3 a Memory configuration error has recovered May also be shown as 816f070c2b8300...

Page 1794: ...hysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 7 in Compute Book 3 a Memory configuration error has recovered May also be shown as 816f070c2b830007 or 0x816f070c2b830007 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no act...

Page 1795: ...30009 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b83000a Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 10 in Compute Book 3 a Memory configuration error has reco...

Page 1796: ...Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 12 in Compute Book 3 a Memory configuration error has recovered May also be shown as 816f070c2b83000c or 0x816f070c2b83000c Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Respon...

Page 1797: ...r 0x816f070c2b83000e Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b83000f Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 15 in Compute Book 3 a Memory configuration...

Page 1798: ...AT ID 0127 User Response Information only no action is required 816f070c 2b830011 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 17 in Compute Book 3 a Memory configuration error has recovered May also be shown as 816f070c2b830011 or 0x816f070c2b830011 Severity Info Serviceable No Automatically notify support No Alert Catego...

Page 1799: ...te Book 3 a Memory configuration error has recovered May also be shown as 816f070c2b830013 or 0x816f070c2b830013 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b830014 Configuration error for PhysicalMemoryElementName on Subsystem MemoryEle...

Page 1800: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b830016 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 22 in Compute Book 3 a Memory configuration error has recovered May also be shown as 816f070c2b8...

Page 1801: ...or PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 24 in Compute Book 3 a Memory configuration error has recovered May also be shown as 816f070c2b830018 or 0x816f070c2b830018 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only n...

Page 1802: ...b840001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b840002 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 2 in Compute Book 4 a Memory configuration error has rec...

Page 1803: ...onfiguration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 4 in Compute Book 4 a Memory configuration error has recovered May also be shown as 816f070c2b840004 or 0x816f070c2b840004 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response...

Page 1804: ... or 0x816f070c2b840006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b840007 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 7 in Compute Book 4 a Memory configuratio...

Page 1805: ...T ID 0127 User Response Information only no action is required 816f070c 2b840009 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 9 in Compute Book 4 a Memory configuration error has recovered May also be shown as 816f070c2b840009 or 0x816f070c2b840009 Severity Info Serviceable No Automatically notify support No Alert Category...

Page 1806: ...ute Book 4 a Memory configuration error has recovered May also be shown as 816f070c2b84000b or 0x816f070c2b84000b Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b84000c Configuration error for PhysicalMemoryElementName on Subsystem MemoryEl...

Page 1807: ...atically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b84000e Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 14 in Compute Book 4 a Memory configuration error has recovered May also be shown as 816f070c2b840...

Page 1808: ...hysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 16 in Compute Book 4 a Memory configuration error has recovered May also be shown as 816f070c2b840010 or 0x816f070c2b840010 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no ac...

Page 1809: ...40012 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b840013 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 19 in Compute Book 4 a Memory configuration error has reco...

Page 1810: ...Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 21 in Compute Book 4 a Memory configuration error has recovered May also be shown as 816f070c2b840015 or 0x816f070c2b840015 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Respon...

Page 1811: ...r 0x816f070c2b840017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response Information only no action is required 816f070c 2b840018 Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted IMM has reported on DIMM 24 in Compute Book 4 a Memory configuration...

Page 1812: ...esponse Information only no action is required 816f070d 0400ffff Rebuild completed for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild Drive 0 has Completed May also be shown as 816f070d0400ffff or 0x816f070d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0179 User Respons...

Page 1813: ...16f070d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0179 User Response Information only no action is required 816f070d 0403ffff Rebuild completed for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild Drive 3 has Completed May also be shown as 816f070d0403ffff or 0x816f070...

Page 1814: ...ired 816f070d 0405ffff Rebuild completed for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild Drive 5 has Completed May also be shown as 816f070d0405ffff or 0x816f070d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0179 User Response Information only no action is required 8...

Page 1815: ...Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0179 User Response Information only no action is required 816f070d 0408ffff Rebuild completed for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild Drive 8 has Completed May also be shown as 816f070d0408ffff or 0x816f070d0408ffff Severity Info S...

Page 1816: ...ild completed for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild Drive 10 has Completed May also be shown as 816f070d040affff or 0x816f070d040affff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0179 User Response Information only no action is required 816f070d 040bffff Rebuild c...

Page 1817: ...le No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0179 User Response Information only no action is required 816f070d 040dffff Rebuild completed for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild Drive 13 has Completed May also be shown as 816f070d040dffff or 0x816f070d040dffff Severity Info Serviceable No...

Page 1818: ...d completed for Array in system ComputerSystemElementName IMM has detected that an Array Rebuild Drive 15 has Completed May also be shown as 816f070d040fffff or 0x816f070d040fffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0179 User Response Information only no action is required 816f0807 0301ffff ProcessorEl...

Page 1819: ... No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0060 User Response Information only no action is required 816f0807 0303ffff ProcessorElementName has been Enabled IMM has reported Microprocessor 3 has been Enabled May also be shown as 816f08070303ffff or 0x816f08070303ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ...

Page 1820: ...or more microprocessors have been enabled May also be shown as 816f08072583ffff or 0x816f08072583ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0060 User Response Information only no action is required 816f0813 2581ffff Bus SensorElementName has recovered from an Uncorrectable Bus Error IMM has detected that...

Page 1821: ... Information Prefix PLAT ID 0241 User Response Information only no action is required 816f0813 2583ffff Bus SensorElementName has recovered from an Uncorrectable Bus Error IMM has reported that the system has recovered from a bus uncorrectable error May also be shown as 816f08132583ffff or 0x816f08132583ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other...

Page 1822: ...mpute Book 1 has been turned off May also be shown as 816f090c2b810002 or 0x816f090c2b810002 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b810003 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on...

Page 1823: ...onse Information only no action is required 816f090c 2b810005 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 5 in Compute Book 1 has been turned off May also be shown as 816f090c2b810005 or 0x816f090c2b810005 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0...

Page 1824: ...so be shown as 816f090c2b810007 or 0x816f090c2b810007 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b810008 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 8 in Compute Book 1 has been turn...

Page 1825: ...uired 816f090c 2b81000a PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 10 in Compute Book 1 has been turned off May also be shown as 816f090c2b81000a or 0x816f090c2b81000a Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no...

Page 1826: ...x816f090c2b81000c Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b81000d PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 13 in Compute Book 1 has been turned off May also be shown as 816f090...

Page 1827: ...090c 2b81000f PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 15 in Compute Book 1 has been turned off May also be shown as 816f090c2b81000f or 0x816f090c2b81000f Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is...

Page 1828: ...0011 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b810012 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 18 in Compute Book 1 has been turned off May also be shown as 816f090c2b810012 or ...

Page 1829: ...14 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 20 in Compute Book 1 has been turned off May also be shown as 816f090c2b810014 or 0x816f090c2b810014 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 8...

Page 1830: ...y Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b810017 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 23 in Compute Book 1 has been turned off May also be shown as 816f090c2b810017 or 0x816f090c2b...

Page 1831: ...hysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling in Compute Book 1 has been turned off May also be shown as 816f090c2b81ffff or 0x816f090c2b81ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b82000...

Page 1832: ...y Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b820003 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 3 in Compute Book 2 has been turned off May also be shown as 816f090c2b820003 or 0x816f090c2b8...

Page 1833: ...ryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 5 in Compute Book 2 has been turned off May also be shown as 816f090c2b820005 or 0x816f090c2b820005 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b820006...

Page 1834: ...eable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b820008 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 8 in Compute Book 2 has been turned off May also be shown as 816f090c2b820008 or 0x816f090c2b820008 Severit...

Page 1835: ...ame on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 10 in Compute Book 2 has been turned off May also be shown as 816f090c2b82000a or 0x816f090c2b82000a Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b82000b Physical...

Page 1836: ...y notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b82000d PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 13 in Compute Book 2 has been turned off May also be shown as 816f090c2b82000d or 0x816f090c2b82000d Severity Info Serviceable N...

Page 1837: ...e is no longer Throttled DIMM throttling on DIMM 15 in Compute Book 2 has been turned off May also be shown as 816f090c2b82000f or 0x816f090c2b82000f Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b820010 PhysicalMemoryElementName on Subsystem Me...

Page 1838: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b820012 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 18 in Compute Book 2 has been turned off May also be shown as 816f090c2b820012 or 0x816f090c2b820012 Severity Info Serviceable No Automatically...

Page 1839: ...e is no longer Throttled DIMM throttling on DIMM 20 in Compute Book 2 has been turned off May also be shown as 816f090c2b820014 or 0x816f090c2b820014 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b820015 PhysicalMemoryElementName on Subsystem Me...

Page 1840: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b820017 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 23 in Compute Book 2 has been turned off May also be shown as 816f090c2b820017 or 0x816f090c2b820017 Severity Info Serviceable No Automatically...

Page 1841: ...stem MemoryElementName is no longer Throttled DIMM throttling in Compute Book 2 has been turned off May also be shown as 816f090c2b82ffff or 0x816f090c2b82ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b830001 PhysicalMemoryElementName on Su...

Page 1842: ...y notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b830003 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 3 in Compute Book 3 has been turned off May also be shown as 816f090c2b830003 or 0x816f090c2b830003 Severity Info Serviceable No...

Page 1843: ...me is no longer Throttled DIMM throttling on DIMM 5 in Compute Book 3 has been turned off May also be shown as 816f090c2b830005 or 0x816f090c2b830005 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b830006 PhysicalMemoryElementName on Subsystem Me...

Page 1844: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b830008 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 8 in Compute Book 3 has been turned off May also be shown as 816f090c2b830008 or 0x816f090c2b830008 Severity Info Serviceable No Automatically ...

Page 1845: ...e is no longer Throttled DIMM throttling on DIMM 10 in Compute Book 3 has been turned off May also be shown as 816f090c2b83000a or 0x816f090c2b83000a Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b83000b PhysicalMemoryElementName on Subsystem Me...

Page 1846: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b83000d PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 13 in Compute Book 3 has been turned off May also be shown as 816f090c2b83000d or 0x816f090c2b83000d Severity Info Serviceable No Automatically...

Page 1847: ...e is no longer Throttled DIMM throttling on DIMM 15 in Compute Book 3 has been turned off May also be shown as 816f090c2b83000f or 0x816f090c2b83000f Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b830010 PhysicalMemoryElementName on Subsystem Me...

Page 1848: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b830012 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 18 in Compute Book 3 has been turned off May also be shown as 816f090c2b830012 or 0x816f090c2b830012 Severity Info Serviceable No Automatically...

Page 1849: ...e is no longer Throttled DIMM throttling on DIMM 20 in Compute Book 3 has been turned off May also be shown as 816f090c2b830014 or 0x816f090c2b830014 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b830015 PhysicalMemoryElementName on Subsystem Me...

Page 1850: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b830017 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 23 in Compute Book 3 has been turned off May also be shown as 816f090c2b830017 or 0x816f090c2b830017 Severity Info Serviceable No Automatically...

Page 1851: ...stem MemoryElementName is no longer Throttled DIMM throttling in Compute Book 3 has been turned off May also be shown as 816f090c2b83ffff or 0x816f090c2b83ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b840001 PhysicalMemoryElementName on Su...

Page 1852: ...y notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b840003 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 3 in Compute Book 4 has been turned off May also be shown as 816f090c2b840003 or 0x816f090c2b840003 Severity Info Serviceable No...

Page 1853: ...me is no longer Throttled DIMM throttling on DIMM 5 in Compute Book 4 has been turned off May also be shown as 816f090c2b840005 or 0x816f090c2b840005 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b840006 PhysicalMemoryElementName on Subsystem Me...

Page 1854: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b840008 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 8 in Compute Book 4 has been turned off May also be shown as 816f090c2b840008 or 0x816f090c2b840008 Severity Info Serviceable No Automatically ...

Page 1855: ...e is no longer Throttled DIMM throttling on DIMM 10 in Compute Book 4 has been turned off May also be shown as 816f090c2b84000a or 0x816f090c2b84000a Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b84000b PhysicalMemoryElementName on Subsystem Me...

Page 1856: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b84000d PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 13 in Compute Book 4 has been turned off May also be shown as 816f090c2b84000d or 0x816f090c2b84000d Severity Info Serviceable No Automatically...

Page 1857: ...e is no longer Throttled DIMM throttling on DIMM 15 in Compute Book 4 has been turned off May also be shown as 816f090c2b84000f or 0x816f090c2b84000f Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b840010 PhysicalMemoryElementName on Subsystem Me...

Page 1858: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b840012 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 18 in Compute Book 4 has been turned off May also be shown as 816f090c2b840012 or 0x816f090c2b840012 Severity Info Serviceable No Automatically...

Page 1859: ...e is no longer Throttled DIMM throttling on DIMM 20 in Compute Book 4 has been turned off May also be shown as 816f090c2b840014 or 0x816f090c2b840014 Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b840015 PhysicalMemoryElementName on Subsystem Me...

Page 1860: ...t No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f090c 2b840017 PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM throttling on DIMM 23 in Compute Book 4 has been turned off May also be shown as 816f090c2b840017 or 0x816f090c2b840017 Severity Info Serviceable No Automatically...

Page 1861: ...emoryElementName is no longer Throttled DIMM throttling in Compute Book 4 has been turned off May also be shown as 816f090c2b84ffff or 0x816f090c2b84ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0143 User Response Information only no action is required 816f0a07 0301ffff The Processor ProcessorElementName is...

Page 1862: ...rviceable No Automatically notify support No Alert Category Warning CPU SNMP Trap ID 42 CIM Information Prefix PLAT ID 0039 User Response Information only no action is required 816f0a07 0303ffff The Processor ProcessorElementName is no longer operating in a Degraded State IMM has detected Microprocessor 3 is no longer running in the Degraded state May also be shown as 816f0a070303ffff or 0x816f0a0...

Page 1863: ...MemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 1 in Compute Book 1 has been deasserted May also be shown as 816f0a0c2b810001 or 0x816f0a0c2b810001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required ...

Page 1864: ...10003 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b810004 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 4 in Compute B...

Page 1865: ...mperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 6 in Compute Book 1 has been deasserted May also be shown as 816f0a0c2b810006 or 0x816f0a0c2b810006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 U...

Page 1866: ... 0x816f0a0c2b810008 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b810009 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM ...

Page 1867: ...7 User Response Information only no action is required 816f0a0c 2b81000b An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 11 in Compute Book 1 has been deasserted May also be shown as 816f0a0c2b81000b or 0x816f0a0c2b81000b Severity Info Serviceable No Automatically notify support No Aler...

Page 1868: ...emory on DIMM 13 in Compute Book 1 has been deasserted May also be shown as 816f0a0c2b81000d or 0x816f0a0c2b81000d Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b81000e An Over Temperature Condition has been removed on the PhysicalMemo...

Page 1869: ...ically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b810010 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 16 in Compute Book 1 has been deasserted May also be sho...

Page 1870: ...been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 18 in Compute Book 1 has been deasserted May also be shown as 816f0a0c2b810012 or 0x816f0a0c2b810012 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Informatio...

Page 1871: ...014 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b810015 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 21 in Compute Bo...

Page 1872: ...emperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 23 in Compute Book 1 has been deasserted May also be shown as 816f0a0c2b810017 or 0x816f0a0c2b810017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147...

Page 1873: ...f0a0c2b81ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b820001 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 1 in C...

Page 1874: ...47 User Response Information only no action is required 816f0a0c 2b820003 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 3 in Compute Book 2 has been deasserted May also be shown as 816f0a0c2b820003 or 0x816f0a0c2b820003 Severity Info Serviceable No Automatically notify support No Aler...

Page 1875: ...mory on DIMM 5 in Compute Book 2 has been deasserted May also be shown as 816f0a0c2b820005 or 0x816f0a0c2b820005 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b820006 An Over Temperature Condition has been removed on the PhysicalMemory...

Page 1876: ...atically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b820008 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 8 in Compute Book 2 has been deasserted May also be sh...

Page 1877: ...en removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 10 in Compute Book 2 has been deasserted May also be shown as 816f0a0c2b82000a or 0x816f0a0c2b82000a Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information ...

Page 1878: ...2000c Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b82000d An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 13 in Compute ...

Page 1879: ...mperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 15 in Compute Book 2 has been deasserted May also be shown as 816f0a0c2b82000f or 0x816f0a0c2b82000f Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 ...

Page 1880: ... 0x816f0a0c2b820011 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b820012 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM ...

Page 1881: ...7 User Response Information only no action is required 816f0a0c 2b820014 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 20 in Compute Book 2 has been deasserted May also be shown as 816f0a0c2b820014 or 0x816f0a0c2b820014 Severity Info Serviceable No Automatically notify support No Aler...

Page 1882: ...emory on DIMM 22 in Compute Book 2 has been deasserted May also be shown as 816f0a0c2b820016 or 0x816f0a0c2b820016 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b820017 An Over Temperature Condition has been removed on the PhysicalMemo...

Page 1883: ...utomatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b82ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on Compute Book 2 has been deasserted May also be shown as...

Page 1884: ... been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 2 in Compute Book 3 has been deasserted May also be shown as 816f0a0c2b830002 or 0x816f0a0c2b830002 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Informatio...

Page 1885: ...004 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b830005 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 5 in Compute Boo...

Page 1886: ...Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 7 in Compute Book 3 has been deasserted May also be shown as 816f0a0c2b830007 or 0x816f0a0c2b830007 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147...

Page 1887: ...x816f0a0c2b830009 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b83000a An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 10...

Page 1888: ...47 User Response Information only no action is required 816f0a0c 2b83000c An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 12 in Compute Book 3 has been deasserted May also be shown as 816f0a0c2b83000c or 0x816f0a0c2b83000c Severity Info Serviceable No Automatically notify support No Ale...

Page 1889: ...mory on DIMM 14 in Compute Book 3 has been deasserted May also be shown as 816f0a0c2b83000e or 0x816f0a0c2b83000e Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b83000f An Over Temperature Condition has been removed on the PhysicalMemor...

Page 1890: ...atically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b830011 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 17 in Compute Book 3 has been deasserted May also be s...

Page 1891: ...een removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 19 in Compute Book 3 has been deasserted May also be shown as 816f0a0c2b830013 or 0x816f0a0c2b830013 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information...

Page 1892: ...30015 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b830016 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 22 in Compute ...

Page 1893: ...er Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 24 in Compute Book 3 has been deasserted May also be shown as 816f0a0c2b830018 or 0x816f0a0c2b830018 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID ...

Page 1894: ... 0x816f0a0c2b840001 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b840002 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM ...

Page 1895: ...7 User Response Information only no action is required 816f0a0c 2b840004 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 4 in Compute Book 4 has been deasserted May also be shown as 816f0a0c2b840004 or 0x816f0a0c2b840004 Severity Info Serviceable No Automatically notify support No Alert...

Page 1896: ...Memory on DIMM 6 in Compute Book 4 has been deasserted May also be shown as 816f0a0c2b840006 or 0x816f0a0c2b840006 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b840007 An Over Temperature Condition has been removed on the PhysicalMemo...

Page 1897: ...ically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b840009 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 9 in Compute Book 4 has been deasserted May also be show...

Page 1898: ...been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 11 in Compute Book 4 has been deasserted May also be shown as 816f0a0c2b84000b or 0x816f0a0c2b84000b Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Informatio...

Page 1899: ...00d Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b84000e An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 14 in Compute Bo...

Page 1900: ...emperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 16 in Compute Book 4 has been deasserted May also be shown as 816f0a0c2b840010 or 0x816f0a0c2b840010 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147...

Page 1901: ...0x816f0a0c2b840012 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b840013 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 1...

Page 1902: ...47 User Response Information only no action is required 816f0a0c 2b840015 An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName The Over Temperature Condition for Memory on DIMM 21 in Compute Book 4 has been deasserted May also be shown as 816f0a0c2b840015 or 0x816f0a0c2b840015 Severity Info Serviceable No Automatically notify support No Ale...

Page 1903: ...mory on DIMM 23 in Compute Book 4 has been deasserted May also be shown as 816f0a0c2b840017 or 0x816f0a0c2b840017 Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a0c 2b840018 An Over Temperature Condition has been removed on the PhysicalMemor...

Page 1904: ...Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response Information only no action is required 816f0a13 2401ffff Bus SensorElementName has recovered from a Fatal Bus Error IMM has reported that the system has recovered from a fatal SMBus error May also be shown as 816f0a132401ffff or 0x816f0a132401ffff...

Page 1905: ...ing Automatically Notify Support 40000086 00000000 Test Call Home Generated by user arg1 Yes 40000087 00000000 Manual Call Home by user arg1 arg2 Yes 80010202 0701ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Yes 80010202 2801ffff Numeric sensor SysBrd VBAT going low lower critical has asserted Yes 80010902 0701ffff Numeric sensor NumericSensorElementName going...

Page 1906: ...tive failure Yes 8005010d 2b810017 SensorElementName is asserting predictive failure Yes 8005010d 2b810018 SensorElementName is asserting predictive failure Yes 8005010d 2b820001 SensorElementName is asserting predictive failure Yes 8005010d 2b820002 SensorElementName is asserting predictive failure Yes 8005010d 2b820003 SensorElementName is asserting predictive failure Yes 8005010d 2b820004 Senso...

Page 1907: ...ive failure Yes 8005010d 2b830008 SensorElementName is asserting predictive failure Yes 8005010d 2b830009 SensorElementName is asserting predictive failure Yes 8005010d 2b83000a SensorElementName is asserting predictive failure Yes 8005010d 2b83000b SensorElementName is asserting predictive failure Yes 8005010d 2b83000c SensorElementName is asserting predictive failure Yes 8005010d 2b83000d Sensor...

Page 1908: ...0 SensorElementName is asserting predictive failure Yes 8005010d 2b840011 SensorElementName is asserting predictive failure Yes 8005010d 2b840012 SensorElementName is asserting predictive failure Yes 8005010d 2b840013 SensorElementName is asserting predictive failure Yes 8005010d 2b840014 SensorElementName is asserting predictive failure Yes 8005010d 2b840015 SensorElementName is asserting predict...

Page 1909: ...s 806f0021 0b0fffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName Yes 806f0021 0b10ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName Yes 806f0021 2201ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName Yes 806f0021 2582ffff Fault in slot PhysicalConnectorSystemElementName on system ...

Page 1910: ...ted for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b81000b Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b81000c Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b81000d Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName...

Page 1911: ...ed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b820001 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b820002 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b820003 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName ...

Page 1912: ...ted for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b820010 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b820011 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b820012 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName...

Page 1913: ...ed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b830006 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b830007 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b830008 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName ...

Page 1914: ...ted for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b830015 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b830016 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b830017 Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName...

Page 1915: ...ed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b84000b Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b84000c Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f010c 2b84000d Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName ...

Page 1916: ...tName has been disabled due to a detected fault Yes 806f010d 0401ffff The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 0402ffff The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 0403ffff The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 0404ffff The NumericSensorElementName has been disabled due ...

Page 1917: ...ed due to a detected fault Yes 806f010d 2b810007 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b810008 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b810009 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b81000a The NumericSensorElementName has been disabled due to a detected fault Y...

Page 1918: ...led due to a detected fault Yes 806f010d 2b820004 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b820005 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b820006 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b820007 The NumericSensorElementName has been disabled due to a detected fault ...

Page 1919: ...ed due to a detected fault Yes 806f010d 2b830001 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b830002 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b830003 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b830004 The NumericSensorElementName has been disabled due to a detected fault Y...

Page 1920: ...led due to a detected fault Yes 806f010d 2b830017 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b830018 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b83ffff The StorageVolumeElementName has been disabled due to a detected fault Yes 806f010d 2b840001 The NumericSensorElementName has been disabled due to a detected fault ...

Page 1921: ...me has been disabled due to a detected fault Yes 806f010d 2b840014 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b840015 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b840016 The NumericSensorElementName has been disabled due to a detected fault Yes 806f010d 2b840017 The NumericSensorElementName has been disabled due to ...

Page 1922: ...ricSensorElementName for array ComputerSystemElementName Yes 806f020d 0409ffff Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 040affff Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 040bffff Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 040cffff Failure P...

Page 1923: ...ted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b81080f Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b810810 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b810811 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b81081...

Page 1924: ...cted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b82080c Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b82080d Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b82080e Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b8208...

Page 1925: ...ted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b830809 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b83080a Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b83080b Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b83080...

Page 1926: ...cted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b840806 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b840807 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b840808 Failure Predicted on NumericSensorElementName for array ComputerSystemElementName Yes 806f020d 2b8408...

Page 1927: ...array ComputerSystemElementName Yes 806f050c 2581ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b810001 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b810002 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b810003 Memory Log...

Page 1928: ...hed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b810010 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b810011 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b810012 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName...

Page 1929: ...ed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b820006 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b820007 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b820008 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName ...

Page 1930: ...hed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b820015 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b820016 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b820017 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName...

Page 1931: ...ed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b83000b Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b83000c Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b83000d Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName ...

Page 1932: ...hed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b840001 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b840002 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b840003 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName...

Page 1933: ...ed for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b840010 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b840011 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName Yes 806f050c 2b840012 Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName ...

Page 1934: ...as failed Yes 806f060d 040bffff Array ComputerSystemElementName has failed Yes 806f060d 040cffff Array ComputerSystemElementName has failed Yes 806f060d 040dffff Array ComputerSystemElementName has failed Yes 806f060d 040effff Array ComputerSystemElementName has failed Yes 806f060d 040fffff Array ComputerSystemElementName has failed Yes 806f0813 2581ffff An Uncorrectable Bus Error has occurred on ...

Page 1935: ...ive failure Yes 8105010d 2b810018 SensorElementName is asserting predictive failure Yes 8105010d 2b820001 SensorElementName is asserting predictive failure Yes 8105010d 2b820002 SensorElementName is asserting predictive failure Yes 8105010d 2b820003 SensorElementName is asserting predictive failure Yes 8105010d 2b820004 SensorElementName is asserting predictive failure Yes 8105010d 2b820005 Sensor...

Page 1936: ...tive failure Yes 8105010d 2b830009 SensorElementName is asserting predictive failure Yes 8105010d 2b83000a SensorElementName is asserting predictive failure Yes 8105010d 2b83000b SensorElementName is asserting predictive failure Yes 8105010d 2b83000c SensorElementName is asserting predictive failure Yes 8105010d 2b83000d SensorElementName is asserting predictive failure Yes 8105010d 2b83000e Senso...

Page 1937: ...nsorElementName is asserting predictive failure Yes 8105010d 2b84000d SensorElementName is asserting predictive failure Yes 8105010d 2b84000e SensorElementName is asserting predictive failure Yes 8105010d 2b84000f SensorElementName is asserting predictive failure Yes 8105010d 2b840010 SensorElementName is asserting predictive failure Yes 8105010d 2b840011 SensorElementName is asserting predictive ...

Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 1939: ...usually a user action or a change of states that is normal behavior Warning A warning is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error An error typically indicates a failure or critical condition that impairs service or an expected function User response In...

Page 1940: ...r More Mismatched Processors Detected Severity Error User Response Complete the following steps 1 This message could occur with messages about other Processor configuration problems Resolve those messages first 2 If the problem persists ensure that matching processors are installed i e matching option part numbers etc 3 Verify that the Processor s are installed in the correct sockets according to ...

Page 1941: ...cket and replace the compute book first if socket is damaged I 18007 A power segment mismatch has been detected for one or more processor packages Processors have mismatched Power Segments Explanation A power segment mismatch has been detected for one or more processor packages Processors have mismatched Power Segments Severity Error User Response Complete the following steps 1 If this is a newly ...

Page 1942: ...ismatched Bus Speed Severity Error User Response Complete the following steps 1 Verify that the Processor is a valid option that is listed as a Server Proven device for this system If not remove the Processor and install a Server Proven one 2 Verify that matching Processors are installed in the correct Processor sockets according to the service information for this product Correct any mismatch fou...

Page 1943: ...e the following steps 1 Verify that matching Processors are installed in the correct Processor sockets according to the service information for this product 2 Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error 3 Replace the compute book I 1800E A processor model mismatch has been detected for one or more processor packages Processors h...

Page 1944: ... ID for the device is arg4 and the Device ID is arg5 OUT_OF_ RESOURCES PCI Option ROM Explanation The device found at Bus arg1 Device arg2 Function arg3 could not be configured due to resource constraints The Vendor ID for the device is arg4 and the Device ID is arg5 OUT_OF_ RESOURCES PCI Option ROM Severity Info User Response Complete the following steps 1 If this PCIe device and or any attached ...

Page 1945: ...d I O book Related links Updating the firmware on page 119 Replacing the standard I O book on page 227 I 3808004 The IMM System Event log SEL is full IPMI System Event Log is Full Explanation The IMM System Event log SEL is full IPMI System Event Log is Full Severity Info User Response Complete the following steps 1 Use IMM Web Interface to clear event log 2 If IMM communication is unavailable use...

Page 1946: ...covery is complete and no additional action is required 3 If system fails to boot or if flash attempt fails replace the standard I O book I 3868000 BOFM System reset performed to reset adapters BOFM System reset performed to reset adapters Explanation BOFM System reset performed to reset adapters BOFM System reset performed to reset adapters Severity Info User Response Complete the following steps...

Page 1947: ... system event log for uncorrected DIMM failures and replace those DIMMs I 580A6 Memory spare copy has completed successfully Spare Copy Complete Explanation Memory spare copy has completed successfully Spare Copy Complete Severity Info User Response Complete the following steps 1 Check system log for related DIMM failures and replace those DIMMs S 1100B CATERR IERR has asserted on processor arg1 P...

Page 1948: ...ure steps a b and c above are also performed for that adapter before proceeding 3 If problem persists then remove Adapter Card for this slot If system reboots successfully without the adapter replace that card 4 If the system fails to reboot successfully and a second slot within the same node has also logged a PCIe error re insert the adapter from the previous step and remove the second adapter If...

Page 1949: ...Check IBM support site for an applicable device driver firmware update version of service information for this product or other information that applies to this error Load new device driver and any required firmware updates 2 If this node and or any attached cables were recently installed moved serviced or upgraded a Reseat Adapter and any attached cables b Reload Device Driver c If device is not ...

Page 1950: ...detected in the UEFI image Internal UEFI Firmware Fault Detected System halted Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Reflash UEFI image 3 Replace the standard I O book S 3040007 A firmware fault has been detected in the UEFI image Internal UEFI Firmware Fault Detected Sys...

Page 1951: ... to resolve that event 3 Undo recent system changes settings or devices added Verify that the system boots Then re install options one at a time to locate the problem 4 Check IBM support site for an applicable service bulletin or firmware update that applies to this error Update UEFI firmware if applicable 5 Remove and re install CMOS battery for 30 seconds to clear CMOS contents If it boots succe...

Page 1952: ... system 2 If the error is not reported on the subsequent boot no additional recovery action is required 3 If the error persists continue booting system and reflash UEFI image Check whether there are any additional instructions to update to this level of UEFI 4 Replace the standard I O book S 3818007 The firmware image capsules for both flash banks could not be verified CRTM image capsule could not...

Page 1953: ...ore replacing it 4 If problem re occurs on the same DIMM connector replace the other DIMMs on the same memory channel If this is a flash DIMM make sure it is still under warranty before replacing it 5 Replace compute book 6 Trained Service technician only Replace affected Processor S 51006 A memory mismatch has been detected Please verify that the memory configuration is valid One or More Mismatch...

Page 1954: ...e it is still under warranty before replacing it 4 If problem re occurs on the same DIMM connector swap the other DIMMs on the same memory channel across channels one at a time to a different memory channel or Processor check service information for this product Install guide for population requirements for sparing paring modes If problem follows a moved DIMM to a different memory channel replace ...

Page 1955: ...cted Explanation Internal QPI Link Failure Detected Internal QPI Link Failure Detected Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Inspect processor socket for foreign debris or damage If debris is found remove debris 3 If error recurs or socket damage is found replace the comp...

Page 1956: ...Requires Change Settings From F1 DRIVER HEALTH PROTOCOL Missing Configuration Requires Change Settings From F1 Explanation DRIVER HEALTH PROTOCOL Missing Configuraiton Requires Change Settings From F1 DRIVER HEALTH PROTOCOL Missing Configuration Requires Change Settings From F1 Severity Warning User Response Complete the following steps 1 Go to F1 Setup System Settings Settings Driver Health Statu...

Page 1957: ...nect Controller Failed Requires Reboot DRIVER HEALTH PROTOCOL Disconnect Controller Failed Requires Reboot Explanation DRIVER HEALTH PROTOCOL Disconnect Controller Failed Requires Reboot DRIVER HEALTH PROTOCOL Disconnect Controller Failed Requires Reboot Severity Warning User Response Complete the following steps 1 Reboot the system to reconnect the controller 2 If problem persists reflash the ada...

Page 1958: ...Configuration to IMM Explanation An error occurred while saving UEFI settings to the IMM Error Updating System Configuration to IMM Severity Warning User Response Complete the following steps 1 Use F1 Setup Verify and Save Settings to recover settings 2 Reset the IMM 3 AC cycle the system 4 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 5 Re...

Page 1959: ...in asserted state Explanation TPM physical presence is in asserted state TPM physical presence is in asserted state Severity Warning User Response Complete the following steps 1 Complete any administrative tasks requiring the TPM physical presence switch to be in the ON position 2 Restore the physical presence switch to the OFF position and reboot the system 3 Replace the standard I O book W 38680...

Page 1960: ...flash IMM and UEFI firmware 7 Swap the DIMM from the disabled slot with a matching DIMM If the slot remains disabled replace the compute book W 58001 The PFA Threshold limit correctable error logging limit has been exceeded on DIMM number arg1 at address arg2 MC5 Status contains arg3 and MC5 Misc contains arg4 DIMM PFA Threshold Exceeded Explanation The PFA Threshold limit correctable error loggin...

Page 1961: ...everity Info User Response Complete the following steps 1 Check system log for related DIMM failures and replace those DIMMs W 58007 Invalid memory configuration Unsupported DIMM Population detected Please verify memory configuration is valid Unsupported DIMM Population Explanation Invalid memory configuration Unsupported DIMM Population detected Please verify memory configuration is valid Unsuppo...

Page 1962: ...ulation for Lockstep Mode Explanation Invalid memory configuration for Lock Step Mode Please correct memory configuration Unsupported DIMM Population for Lockstep Mode Severity Warning User Response Complete the following steps 1 Make sure that the DIMM connectors are correctly populated for lock step mode according to the service information for this product W 580A7 DIMM Service Action Detected S...

Page 1963: ...S Battery Fault Explanation A CMOS battery error has been detected CMOS Battery Fault Severity Error User Response Complete the following steps 1 If the system was recently Installed Moved or Serviced make sure the battery is properly seated 2 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 3 Replace CMOS Battery 4 Replace the standard I O bo...

Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 1965: ...ve installed new hardware or software in your environment check http www lenovo com serverproven to make sure that the hardware and software is supported by your product Go to http datacentersupport lenovo com to check for information to help you solve the problem Gather the following information to provide to the service technician This data will help the service technician quickly provide a solu...

Page 1966: ... specific Information Centers ThinkSystem products https thinksystem lenovofiles com help index jsp XClarity products https sysmgt lenovofiles com help index jsp Flex System products https flexsystem lenovofiles com help topic com lenovo acc common nav doc ic homepage html System x products https systemx lenovofiles com help topic com lenovo systemx common nav doc ic homepage html NeXtScale System...

Page 1967: ...he U S and Canada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support IBM is Lenovo s preferred service provider for the System x Flex System and NeXtScale System products You can receive hardware service through your Lenovo reseller or from IBM To locate a reseller authorized by Lenovo to provide warranty service go to https datacentersupport lenovo com us en serviceprovider and click...

Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 1969: ...ew editions of the publication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not aff...

Page 1970: ...the largest currently supported drives that are available from Lenovo Maximum memory might require replacement of the standard memory with an optional memory module Each solid state memory cell has an intrinsic finite number of write cycles that the cell can incur Therefore a solid state device has a maximum number of write cycles that it can be subjected to expressed as total bytes written TBW A ...

Page 1971: ... a customer responsibility Table 67 Limits for particulates and gases Contaminant Limits Particulate The room air must be continuously filtered with 40 atmospheric dust spot efficiency MERV 9 according to ASHRAE Standard 52 21 Air that enters a data center must be filtered to 99 97 efficiency or greater using high efficiency particulate air HEPA filters that meet MIL STD 282 The deliquescent relat...

Page 1972: ... must accept any interference received including interference that might cause undesired operation Industry Canada Class A emission compliance statement This Class A digital apparatus complies with Canadian ICES 003 Avis de conformité à la réglementation d Industrie Canada Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada Australia and New Zealand Class A statement At...

Page 1973: ...sbescheinigung laut dem Deutschen Gesetz über die elektromagnetische Verträglichkeit von Betriebsmitteln EMVG vom 20 Juli 2007 früher Gesetz über die elektromagnetische Verträglichkeit von Geräten bzw der EMV EU Richtlinie 2014 30 EU für Geräte der Klasse A Dieses Gerät ist berechtigt in Übereinstimmung mit dem Deutschen EMVG das EG Konformitätszeichen CE zu führen Verantwortlich für die Konformit...

Page 1974: ...ications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A statement People s Republic of China Class A electronic emission statement 1960 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...

Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 1977: ...dvanced Settings Utility program overview 140 air duct front removing 231 air temperature 10 airflow 10 applying current firmware using best practices 43 arrays RAID configuring 140 assembly board replacing 276 storage book 276 assertion event system event log 161 assistance getting 1951 attention notices 5 Australia Class A statement 1958 automated boot recovery ABR 199 automated service request ...

Page 1978: ...rear 33 connectors on the compute book 30 compute book DDR3 30 on the front of the server 24 on the full length I O book 36 on the half length I O book 34 on the rear of the server 31 on the standard I O book 31 rear 31 USB 3 0 26 connectors on the front of the server 24 connectors on the storage book 24 consumable parts 218 removing and replacing 221 contamination particulate and gaseous 10 1957 ...

Page 1979: ...5 DSA Preboot 151 165 DSA Preboot diagnostic program 12 DSA Preboot diagnostic programs running 166 DSA test log viewing 166 DSA sending data 1952 Dynamic System Analysis DSA Preboot diagnostics program 12 E electrical input 10 electronic emission Class A notice 1958 Electronic Service Agent 167 embedded hypervisor using 138 enabling Features on Demand Ethernet software 139 Features on Demand Ethe...

Page 1980: ...ook 266 FlexNode support 19 FOD supported on the server 85 FOD supported on the server 85 front I O panel removing 272 replacing 272 front operator panel 27 controls and LEDs 27 removing 277 replacing 278 front operator panel front replacing 278 front view LED location 24 front view of the server 24 FRU overview 221 FRUs removing and replacing 284 full length I O book 235 236 PCIe expansion module...

Page 1981: ... supply 107 a RAID cache card 97 a RAID flash power module 97 98 an adapter 83 battery system 270 hot swap SAS SATA drive 76 hypervisor flash device 110 in the standard I O book 98 in the storage book 97 memory modules 46 optional adapters 93 the 2 5 inch hot swap SAS SATA backplane 243 the 4x2 5 inch hot swap drive backplane assembly 113 the 4x2 5 inch NVMe PCIe Gen3 solid state drive backplane a...

Page 1982: ...ght path diagnostics 14 152 LEDs description of 159 light path diagnostics LEDs description 160 light path diagnostics panel NMI button 32 local area network LAN 14 Locate button LED 26 lockstep memory mode 57 and memory rank sparing 59 DIMM population 57 DIMM population sequence 57 lockstep mode and memory mirroring 58 log data FFDC 168 log capturing the FFDC 167 log event viewing through the web...

Page 1983: ...ule 133 overview of the power supplies 37 100 overview of the server 1 overview of the supported drives 66 P particulate contamination 10 1957 parts listing 201 parts listing Lenovo System x3850 X6 and x3950 X6Type 6241 203 218 parts listing server 201 parts consumable 218 password 128 administrator 128 power on 128 password administrator setting 129 password power on setting 128 switch on the sta...

Page 1984: ...bilities 18 hot swap power supplies 18 redundant array of independent disks RAID adapter 78 242 related documentation 4 reliability server 17 remote presence feature using 134 remote presence features 120 removing 233 302 306 1 8 inch hot swap SAS SATA drives 238 2 5 inch hot swap SAS SATA drives 238 a 1400 watt or 900 watt hot swap power supply 255 a 750 watt 48 volt to 60 volt dc power supply 29...

Page 1985: ... configuring 120 does not turn off 188 error codes and messages 168 offerings 12 power features 39 reconfiguring an 8 socket server to two 4 socket servers 19 standard I O book 31 turning it off 40 turning it on 40 server backup firmware starting 130 server components 201 server components removing and replacing 221 server configuration updating 117 server features and specifications 5 server firm...

Page 1986: ...multiprocessing 14 system error LED front 26 locate LED front 26 system error LED rear 32 system event logs 162 system firmware information 27 system information LCD display panel 27 29 system power configurations power supply setting 137 system reliability guidelines 45 system event log 161 system event log assertion event 161 system event log deassertion event 161 system locator LED rear 32 syst...

Page 1987: ...s 43 using SSH to log on to the IMM CLI interface 136 Utility program Advanced Settings 140 utility Setup menu choices 123 starting 123 using 123 UUID data updating 140 UUID string 27 UUID updating locally using keyboard controller style 141 locally using LAN over USB 141 remotely over a LAN 142 V video connector front 26 rear 33 video controller integrated specifications 9 video problems 181 194 ...

Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...

Page 1989: ......

Page 1990: ......

Reviews: