Explanation:
A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
2. Reflash UEFI image.
3. Replace the standard I/O book.
•
S.3058004 A Three Strike boot failure has occurred. The system has booted with default UEFI
settings. POST failure has occurred! System booted with default settings.
Explanation:
A Three Strike boot failure has occurred. The system has booted with default UEFI settings.
POST failure has occurred! System booted with default settings.
Severity
Error
User Response
Complete the following steps:
1. Original UEFI settings are still present. If customer desires to continue using the original settings,
select Save Settings.
2. If User did not intentionally trigger the reboots, check logs for probable cause. For example, if
there is a battery fault event, follow the steps to resolve that event.
3. Undo recent system changes (settings or devices added). Verify that the system boots. Then, re-
install options one at a time to locate the problem.
4. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error. Update UEFI firmware if applicable.
5. Remove and re-install CMOS battery for 30 seconds to clear CMOS contents. If it boots
successfully, then restore system settings.
6. Replace the standard I/O book.
•
S.3060007 A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Explanation:
A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
2. Reflash UEFI image.
3. Replace the standard I/O book.
•
S.3070007 A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Explanation:
A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Appendix D. UEFI/POST error codes
1937
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......