1. Check system log for related DIMM failures and replace those DIMMs.
•
S.68005 An error has been detected by the the IIO core logic on Bus [arg1]. The Global Fatal Error
Status register contains [arg2]. The Global Non-Fatal Error Status register contains [arg3]. Please
check error logs for the presence of additional downstream device error data. Critical IOH-PCI
Error
Explanation:
An error has been detected by the the IIO core logic on Bus [arg1]. The Global Fatal Error
Status register contains [arg2]. The Global Non-Fatal Error Status register contains [arg3]. Please check
error logs for the presence of additional downstream device error data. Critical IOH-PCI Error
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
2. Check log for a separate error for an associated PCIe device and service that error.
3. Replace the I/O book reported in the error.
4. Replace the compute book reported in the error.
•
S.680B8 Internal QPI Link Failure Detected. Internal QPI Link Failure Detected
Explanation:
Internal QPI Link Failure Detected. Internal QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
2. Inspect processor socket for foreign debris or damage. If debris is found remove debris.
3. If error recurs, or socket damage is found, replace the compute book.
4. (Trained Service Technician Only) Replace the processor.
•
S.680B9 External QPI Link Failure Detected. External QPI Link Failure Detected
Explanation:
External QPI Link Failure Detected. External QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
2. Inspect processor socket for foreign debris or damage. If debris is found remove debris.
3. If error recurs, or socket damage is found, replace the compute book.
•
W.3048006 UEFI has booted from the backup flash bank due to an Automatic Boot Recovery (ABR)
event. Automated Boot Recovery, Booting Backup UEFI Image
Explanation:
UEFI has booted from the backup flash bank due to an Automatic Boot Recovery (ABR)
event. Automated Boot Recovery, Booting Backup UEFI Image
Severity
Warning
Appendix D. UEFI/POST error codes
1941
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......