May also be shown as 800706031301ffff or 0x800706031301ffff
Severity
Error
Serviceable
yes
Automatically notify support
no
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix:
PLAT
ID:
0530
User Response
– Compute Book 1 VRD: Indicates a problem with either the voltage regulator for CPU1 or
microprocessor 1 itself
– Compute Book 2 VRD: Indicates a problem with either the voltage regulator for CPU2 or
microprocessor 2 itself
– Compute Book 3 VRD: Indicates a problem with either the voltage regulator for CPU3 or
microprocessor 3 itself
– Compute Book 4 VRD: Indicates a problem with either the voltage regulator for CPU4 or
microprocessor 4 itself
– Planar VRD: Indicates a problem with a voltage regulator for the primary system board
– I/O Book 1 VRD: Indicates a problem with a voltage regulator for the IO Module
– I/O Book 2 VRD: Indicates a problem with a voltage regulator for the IO Module
– Storage Book VRD: Indicates a problem with a voltage regulator for the Storage Book Board
– Check the IMM Web event log. This event may be a symptom of an earlier error.
– Depending on the error perform the following steps.
For a CPU BOOK 1 VRD, CPU Book 2 VRD, CPU Book 3 VRD, or CPU Book 4 VRD error:
– Check the IBM support site for service bulletins or firmware updates that apply to this
microprocessor error.
– Replace affected Compute Book.
For a Planar VRD error:
– Replace primary system board.
For a IO Book VRD error:
– Replace IO Book board.
For a Storage Book VRD error:
– Replace Storage Book board.
Related links
– Removing the standard I/O book
– Replacing the standard I/O book
– Removing the storage book
– Replacing the storage book
– Removing a compute book
– Replacing a compute book
•
80070607-2583ffff : Sensor [SensorElementName] has transitioned to non-recoverable.
How the microprocessor's are installed in the system does not match a supported configuration.
May also be shown as 800706072583ffff or 0x800706072583ffff
Severity
648
System x3850 X6 and x3950 X6 Installation and Service Guide
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......