When you install RAID adapters that come with flash power modules in the standard I/O book , install the
flash power modules in the slots inside the standard I/O book air baffle to prevent them from overheating. To
install the flash power modules in the air baffle, complete the following steps:
Step 1. Place the new flash power module into the flash power module slot in the air baffle.
Air baffle
Standard I/O book
Flash power
module slots
Flash power
module
Step 2. If you install the flash power modules in the two slots on the left side (facing the front of the
standard I/O book) of the air baffle, route the cables through the clips and the holes on the side of
the air baffle, as shown in the following illustration. When you install a flash power module in the
slot on the right side of the air baffle, route the cable through the hole under the flash power module
slot.
Step 3. Connect the flash power module cable to the adapter.
Step 4. Close the air baffle cover. Rotate the cover down and press it until it is locked in place.
Step 5. Reinstall the standard I/O book (see “Replacing the standard I/O book” on page 227).
.
Removing and replacing components
267
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......