SDA Operator’s Manual
SDA DBI Controls
The SDA 18000/13000/11000/9000 oscilloscopes achieve higher bandwidth and sample rate
using an innovative LeCroy technology called Digital Bandwidth Interleaving (DBI). This
technology allows resources to be borrowed from unused channels to multiply not only sample
rate but also bandwidth.
00/11000/9000 oscilloscopes achieve higher bandwidth and sample rate
using an innovative LeCroy technology called Digital Bandwidth Interleaving (DBI). This
technology allows resources to be borrowed from unused channels to multiply not only sample
rate but also bandwidth.
SDA18000 DBI Controls
SDA18000 DBI Controls
When 18 GHz is selected, the active channels are either C1 or C4
or both, providing 60 GS/s sampling on the 18 GHz channel, and
20 GS/s sampling on the 6 GHz channel.
When 18 GHz is selected, the active channels are either C1 or C4
or both, providing 60 GS/s sampling on the 18 GHz channel, and
20 GS/s sampling on the 6 GHz channel.
When 11 GHz is selected, the active channels are C1, C3 and C4.
The 11 GHz channel provides 40 GS/s sampling, while the 6 GHz
channels provide 20 GS/s sampling.
When 11 GHz is selected, the active channels are C1, C3 and C4.
The 11 GHz channel provides 40 GS/s sampling, while the 6 GHz
channels provide 20 GS/s sampling.
When 6 GHz is selected, all 4 channels are active, each providing
20 GS/s.
When 6 GHz is selected, all 4 channels are active, each providing
20 GS/s.
6 GHz mode
Bandwidth
18 GHz
6 GHz
11 GHz
6 GHz
6 GHz
Number of Channels
1
1
1
2
4
Sample Rate
60 GS/s
20 GS/s
40 GS/s
20 GS/s
20 GS/s
18 GHz mode
11 GHz mode
6 GHz mode
Bandwidth
18 GHz
6 GHz
11 GHz
6 GHz
6 GHz
Number of Channels
1
1
1
2
4
Sample Rate
60 GS/s
20 GS/s
40 GS/s
20 GS/s
20 GS/s
18 GHz mode
11 GHz mode
SDA 13000/11000/9000 DBI Controls
When 13/11/9 GHz is selected, the active channels are either C2 or
C3 or both, providing 40 GS/s sampling on each channel. For 6
GHz bandwidth, all four channels can be used, providing 20 GS/s
sampling on each channel. Channels can be set to allow 13/11/9
GHz and 6 GHz bandwidths at the same time, as shown at left.
Bandwidth
13/11/9 GHz
6 GHz
Number of Channels
2
4
Sample Rate
40 GS/s
20 GS/s
SDA-OM-E Rev H
329
Summary of Contents for SDA
Page 1: ...SERIAL DATA ANALYZER OPERATOR S MANUAL December 2007 ...
Page 223: ...SDA Operator s Manual Example 6 SDA OM E Rev H 223 ...
Page 225: ...SDA Operator s Manual SDA OM E Rev H 225 ...
Page 246: ...246 SDA OM E Rev H ...
Page 247: ...SDA Operator s Manual Excel Example 5 Using a Surface Plot SDA OM E Rev H 247 ...
Page 279: ...SDA Operator s Manual Convolving two signals SDA OM E Rev H 279 ...
Page 310: ...The jitter wizard is accessed from the Analysis drop down menu 310 SDA OM E Rev H ...
Page 327: ...SDA Operator s Manual SDA OM E Rev H 327 ...
Page 328: ...328 SDA OM E Rev H ...
Page 394: ...394 SDA OM E Rev H ...