Parameter
Description
Definition
Notes
Period@level
Period at a specified level and
slope for every cycle in waveform.
Reference levels and edge-
transition polarity can be
selected. Hysteresis argument
used to discriminate levels
from noise in data.
Available with JTA2, AORM,
ENET, SDA, and XMAP
options.
Standard in DDA-5005A,
SDA100G, and WavePro
7000A scopes.
Per Pulse Sym Symmetry of RZ pulse around eye
aperture center
Standard in SDA and
WaveExpert scopes.
Persist Area
Area under mean persistence trace
Standard in SDA and
WaveExpert scopes.
Persist Max
Highest vertical value of input
persistence
Standard in SDA and
WaveExpert scopes.
Persist Mean
Average of persistence data
Standard in SDA and
WaveExpert scopes.
Persist Mid
Mid level between Maximum and
Minimum data
Standard in SDA and
WaveExpert scopes.
Persist Min
Lowest vertical value of input
persistence
Standard in SDA and
WaveExpert scopes.
Persist PkPk
Difference between maximum and
minimum data values
Standard in SDA and
WaveExpert scopes.
Persist RMS
Root mean square of persistence
data
Standard in SDA and
WaveExpert scopes.
Phase
Phase difference between signal
analyzed and signal used as
reference. You can set the output
type to percent, degrees, or
radians. After setting up the
reference, touch the
More
tab for
signal setups.
Phase difference
between signal and
reference
Standard parameter.
Pj
Periodic component of jitter
Available with SDA option.
Power Factor
Ratio of real to apparent power
Available with PMA2 option.
PW50
Average pulse width at the 50%
point between the local baseline
and the local peak or trough.
Hysteresis argument used to
discriminate levels from noise
in data.
Available with DDM2 option.
Standard in DDA-5005A.
PW50-
Average pulse width at the 50%
point between the local baseline
and the local trough.
Hysteresis argument used to
discriminate levels from noise
in data.
Available with DDM2 option.
Standard in DDA-5005A.
170
SDA-OM-E Rev H
Summary of Contents for SDA
Page 1: ...SERIAL DATA ANALYZER OPERATOR S MANUAL December 2007 ...
Page 223: ...SDA Operator s Manual Example 6 SDA OM E Rev H 223 ...
Page 225: ...SDA Operator s Manual SDA OM E Rev H 225 ...
Page 246: ...246 SDA OM E Rev H ...
Page 247: ...SDA Operator s Manual Excel Example 5 Using a Surface Plot SDA OM E Rev H 247 ...
Page 279: ...SDA Operator s Manual Convolving two signals SDA OM E Rev H 279 ...
Page 310: ...The jitter wizard is accessed from the Analysis drop down menu 310 SDA OM E Rev H ...
Page 327: ...SDA Operator s Manual SDA OM E Rev H 327 ...
Page 328: ...328 SDA OM E Rev H ...
Page 394: ...394 SDA OM E Rev H ...