Instructions for the installer
343
LPG
NATURAL GAS
Using
flexible rubber pipes
with a max. length of
1500 mm
:
•
do not allow the pipes to be constricted or crushed;
•
pipes must not be subject to tractive force or torsional stress;
•
do not allow the pipes to come into contact with cutting or sharp edges, etc...
•
do not allow the pipes to come into contact with parts that can reach temperatures of
70°C
above room temperature;
•
make sure the entire length of the pipes can be inspected.
The unit must be coated in heat-resistant material
(
minimum 90°C
). If the appliance is installed close to
other units, the minimum space suggested in the following
diagram must be left.