background image

 

 

 

 

 

 

 

INSTRUCTION MANUAL 

 

GAS COOKTOP 

Appliance Class: 3 

 

 

 

 

Model: 

24 " :JZT-HQ4B67AAZXA    JZT-HQ4L67AAZXA 

30 " :JZT-HQ5B70CAZXA    JZT-HQ5L70AAZXA   

34 " :JZT-HQ5B90AAZXA    JZT-HQ5B90CAZXA    JZT-HQ5L90AAZXA     

36" : JZT-HQ5B90SAZXA    JZT-HQ5L90IAZXA 

                                                                                           

   

  Item : 

24 " :EMPV-24GC4B67A    EMPV-24GC4L67A 

30 " :EMPV-30GC5B70C    EMPV-30GC5L70A     

34 " :EMPV-34GC5B90A    EMPV-34GC5B90C    EMPV-34GC5L90A     

36" : EMPV-36GC5B90S    EMPV-36GC5L90I 

 

Summary of Contents for EMPV-24GC4B67A

Page 1: ...4L67AAZXA 30 JZT HQ5B70CAZXA JZT HQ5L70AAZXA 34 JZT HQ5B90AAZXA JZT HQ5B90CAZXA JZT HQ5L90AAZXA 36 JZT HQ5B90SAZXA JZT HQ5L90IAZXA Item 24 EMPV 24GC4B67A EMPV 24GC4L67A 30 EMPV 30GC5B70C EMPV 30GC5L70A 34 EMPV 34GC5B90A EMPV 34GC5B90C EMPV 34GC5L90A 36 EMPV 36GC5B90S EMPV 36GC5L90I ...

Page 2: ...ances Inc 15253 Don Julian Rd City of Industry CA 91745 USA www empava com The instructions shall be marked with directions to the installer to leave them with the appliance and to the consumer to retain them for future reference ...

Page 3: ... may be achieved by having the plug accessible or by incorporating a switch in the fixed wiring in accordance with the wiring rules WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance W...

Page 4: ...Contents Cooktop Description Important Information Operation Maintenance and Cleaning Troubleshooting Instructions for the Installer Important safety requirements Installation ...

Page 5: ...tion must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or in Canada the Natural Gas and Propane Installation Code CSA B149 1 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code NFPA 70 or the Canadian Electric Code CSA C22 1 02 ...

Page 6: ...m 2 burner 2 12000Btu hr in 132 mm 3 burner 3 6000Btu hr in 65 mm 4 burner 4 10200Btu hr in 95 mm Operating Instructions button 1 is for burner 10 button 2 is for burner 6 button 3 is for burner 8 button 4 is for burner 7 button 5 is for burner 9 1 burner 6 6000Btu hr in 65 mm 2 burner 7 10200Btu hr in 95 mm 3 burner 8 12000Btu hr in 132 mm 4 burner 9 6000Btu hr in 65 mm 5 Burner 10 3400Btu hr in ...

Page 7: ...0Btu hr in 132 mm 4 burner 9 6000Btu hr in 65 mm 5 Burner 10 3400Btu hr in 45 mm 1 burner 6 6000Btu hr in 65 mm 2 burner 7 10200Btu hr in 95 mm 3 burner 8 12000Btu hr in 132 mm 4 burner 9 6000Btu hr in 65 mm 5 Burner 10 3400Btu hr in 45 mm Total heat input 37600Btu hr JZT HQ5L70AAZXA EMPV 30GC5L70A Operating Instructions button 1 is for burner 10 button 2 is for burner 6 button 3 is for burner 8 b...

Page 8: ...0Btu hr in 132 mm 4 burner 9 6000Btu hr in 65 mm 5 Burner 10 3400Btu hr in 45 mm Total heat input 37600Btu hr JZT HQ5B90SAZXA EMPV 36GC5B90S 1 burner 6 6000Btu hr in 65 mm 2 burner 7 10200Btu hr in 95 mm 3 burner 8 12000Btu hr in 132 mm 4 burner 9 6000Btu hr in 65 mm 5 Burner 10 3400Btu hr in 45 mm Operating Instructions button 1 is for burner 10 button 2 is for burner 6 button 3 is for burner 8 b...

Page 9: ...ation regulations Particular attention shall be given to the relevant requirements regarding ventilation Read the instructions before installing or using this appliance The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The appliance must be isolated from th...

Page 10: ...cooking only It is not designed for commercial or industrial purposes When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose When using the gas cooktop for a long period of time the ventilation should be improved by openi...

Page 11: ...ct please contact your local city office your household waste disposal service or the shop where you purchased the product Operation Lighting Simply press the knob in turn anticlockwise to ignition position star icon Press the ignition device and hold the knob till the burner is ignited Before releasing knob ensure a flame is established If the burner fails to ignite put into off position and try ...

Page 12: ...ouple Figure 10 When switching on the mains after installation or a power cut it is quite normal for the spark generator to be activated automatically To ensure maximum burner efficiency you had better use pots and pans with a flat bottom fitting the size of the burner used see table Do not use rim based or convex based vessels on the hotplate burners W A R NI N G As soon as a liquid starts boilin...

Page 13: ...e tong there may be unsmooth ignition revolve the switch to largest flame position and ignite again Maintenance and Cleaning Before any maintenance or cleaning can be carried out you must DISCONNECT the gas cooktop from the electricity supply The gas cooktop is best cleaned while it is still warm as spillage can be removed more easily than if it is left to cool Control Panel Sign gas valve is shut...

Page 14: ...king be sure to keep them in very clean condition Maintenance instructions suggesting We suggest to clean it every six months 1 Keeping appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 2 Not obstructing the flow of combustion and ventilation air 3 Visually checking pilot s and burner flames with pictorial representation A Remove the utensil s...

Page 15: ...dth 760mm Depth 450mm for model HQ3B70AMGIK Width 760mm Depth 510mm for model HQ5B70AMGIK HQ5L70AMGIK HQ5B70BMGIK HQ5B70CMGIK Width 860mm Depth 510mm for model HQ5B90DMGIK HQ5B90EMGIK HQ5B90FMGIK HQ5B90GMGIK HQ5L90DMGIK HQ5L90EMGIK HQ5B90LMGIK Width 860mm Depth 500mm for model HQ5B90AMGIK HQ5B90BMGIK HQ5B90CMGIK HQ5L90AMGIK HQ5L90CMGIK HQ5B90RMGIK Width 900mm Depth 510mm for model HQ5B90IMGIK HQ5B...

Page 16: ...l can be fitted directly above the cooktops is 762 mm Maximum depth for the overhead cabinets is 330 mm The distance from the front edge of the cooktop to the front edge of the countertop should be 76mm The distance between the closet should be 600mm not less than the depth of the cooktop itself see Figure 12 Notice that a horizontal separation below the base of the hotplate is needed The minimum ...

Page 17: ... See Figure 13 Figure 13 When you need to change the gas cooktop you must first close the air supply valve and the cooktop valve unplug the plug of models with AC power supply only after that you can remove the connector hose or threaded connector and then move the gas cooktop Warn of the potential hazards associated with storage cabinet areas above appliances Misoperation can cause fire All cord ...

Page 18: ...install those nozzles in the Conversion Kit bag to each burner base correspondingly Save the orifices removed from the appliance for future use 4 Input inlet pressure of 11 in wc 2740Pa coat the nozzle joints and the gas pressure regulator joints with moderate amounts of soapy water there shall be no bubbling 5 Place the burner burner cap check if the position between the ignition pin and the burn...

Page 19: ...hority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as sp...

Page 20: ...or of the cabinet adequately Pressure Regulator Installation A Cooktop air pipe joint B Pressure Regulator C Gas fitting First make sure that the pressure regulator arrow points toward the cooktop air pipe joint and then fasten the pressure regulator to the cooktop air pipe Then install the gas fitting on the other side of the pressure regulator See Figure 15 Figure 15 Gas Connection and check D E...

Page 21: ...odel The GAS COOKTOP MUST BE EARTHED If the cooktops to be connected to a 120V 60 Hz AC electrical supply Before switching on make sure the electricity supply voltage is the same as that indicated on the cooktops rating label Ensure that the cooktops supply cable does not come into contact with surfaces with temperatures higher than 50 deg C WARNING Electrical Grounding Instructions This appliance...

Page 22: ...appliance with four burners Figure 20 for the appliance with three burners Figure 21 for the appliance with five burners Use with D C battery When your cooktop is the one fitted with D C supply device only you are suggested to use one 1 5V ...

Page 23: ...tery Be sure that the battery is well fixed then you can follow the Lighting procedure Take off the battery if you won t use the cooktop for a long time Check the working performance every time before cooking ...

Reviews: