BiG Pack 870 HDP, BiG Pack 870 HDP XC
Error number
Possible cause
Remedy
522078-15
The upper limit value of the moisture
measurement has been exceeded.
•
Check the setting and correct if
required.
522079-17
The lower limit value of the moisture
measurement has not been reached.
•
Check the setting and correct if
required.
522080-2
S7
The "Switch on blade cassette"
pushbutton is sticking.
•
Eliminate the cause of the
pushbutton sticking.
•
Replace the pushbutton.
522081-2
S8
The "Switch off blade cassette"
pushbutton is sticking.
522085-13
The "Baling ram at rear" sensor is
defective.
•
Replace the sensor.
522086-13
The "Baling ram at front" sensor is
defective.
522087-17
The "Measure" sensor and the
"Calibrate" sensor have been
interchanged.
•
Swap the plugs of the "Measure"
and "Calibrate" sensors.
522088-7
"Packer feed (feeder strip)" sensor
•
Set the sensor.
8.16.1.6
Error message from sensors 522100 – 522299
All error messages from sensors are configured according to the following sample:
e.g. error message "522101-6
B 8
"
522101
6
B 8
SPN (Suspect Parameter Number)
FMI
Icon
Designation
Explanation
SPN (Suspect Parameter Number)
Error number
FMI
.
Icon
Meaning of the icons,
8.16.1.7
Error message from actuators 522300 – 522499
All error messages from actuators are configured according to the following sample:
e.g. error message "522301-6
K17
"