External ISOBUS Terminal
137
Pos: 85.24.7 /Ü berschriften/Ü berschriften 2/F-J/I/ISOBU S Shortcut Button nicht vor handen @ 362\mod_1439546689770_78.docx @ 2669647 @ 2 @ 1
13.2
ISOBUS Shortcut Button not Available
Pos: 85.24.8 /BA/Info-Center/Iso-Bedienung/ISOBUS Short C ut Button nicht vor handen BiG Pack_Bil d @ 382\mod_1444226150779_78.docx @ 2754820 @ @ 1
ISB
ISB
1
CC000958
Fig. 92
Pos: 85.24.9 /Layout Module /----------------Leerzeile 5 Pt.-------------------- @ 120\mod_1342592918145_0.docx @ 1092566 @ @ 1
Pos: 85.24.10 /BA/Info-C enter /CCI-ISOBUS-T ermi nal /Modul e für Beipack/ISOBU S Short C ut ButtonHinweis kein ISOBUS Shor t Cut Button vor handen_nurBETA II @ 392\mod_1445961020726_78.docx @ 2805303 @ @ 1
The KRONE BETA II terminal does not feature an ISOBUS shortcut button. Symbol (1) is shown
in the display. The machine functions cannot be switched off via the ISOBUS shortcut button.
Pos: 85.24.11 /Ü berschriften/Ü berschriften 2/A- E/A/Abweichende F unkti onen zum KR ONE ISOBUS Ter mi nal @ 362\mod_1439551355532_78.docx @ 2669871 @ 2 @ 1
13.3
Deviating Functions from KRONE ISOBUS Terminal
Pos: 85.24.12 /BA/Info-C enter /Iso-Bedi enung/BigPack/Abweichende F unktionen zum KRON E ISOBU S-Ter mi nal @ 380\mod_1443783589778_78.docx @ 2747187 @ @ 1
By means of ISOBUS operation unit, information and control functions of the machine are
provided on the display of the external ISOBUS terminal. The operation with an external
ISOBUS terminal is similar to the KRONE ISOBUS terminal. Before start-up, the functionality of
KRONE ISOBUS terminal is to be read in the operating instructions.
A significant difference to the KRONE ISOBUS terminal is the arrangement of icons and the
number of keys, which are determined by the selected external ISOBUS terminal.
The functions which deviate from KRONE ISOBUS terminal are described in the following.
Pos: 85.24.13 /BA/Info-C enter /Iso-Bedi enung/Abweichende F unktionen C CI_Ter mKontrast und akustische Signal e @ 268\mod_1401118180313_78.docx @ 2029054 @ @ 1
Note
The contrast for the KRONE terminal cannot be called up on other ISO terminals. Adjustment is
performed directly via the ISO terminal, see the operating instructions supplied by the
manufacturer of the ISO terminal.
If necessary, acoustic signals must be enabled from the terminal, see the operating instructions
supplied by the manufacturer of the ISO terminal.
Pos: 85.24.14 /BA/Info-C enter /Iso-Bedi enung/BigPack/Abweichende F unktionen CC I_T er minal Presskl appen @ 47\mod_1285233314609_78.docx @ 456042 @ @ 1
Note
The values for “Bale channel flap pressure/force”, “Bale length” and “Number of MultiBales”
which are set by the scroll wheel in the basic screen on the KRONE ISOBUS terminal CCI, are
set on the ISO terminal with the selection key predetermined by the ISO terminal (refer to the
operating instructions of the ISO terminal manufacturer).