Terminal – machine functions [Medium Plus/Comfort Plus Electronics]
7
Setting the target number of MultiBales
7.25
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
39
Value (2) and the red mark on the bar display = set target bale length
Setting target bale length
Setting range: 1,000 - 2,700 mm / 39 - 106 inch
Change value,
7.25
Setting the target number of MultiBales
INFORMATION
To prevent a mixture of entire bales and MultiBales, set the target number (2) of MultiBales
always at the start of an entire bale.
20
4 cm
38 %
94 /
240
cm
2 /
4
20
4 cm
108 bar
94 /
240
cm
2 /
4
2
2
1
1
EQ001-057
Value (1) = actual number of MultiBales
Value (2) = set target number of MultiBales
Setting target number
ü
The bale length has been set, .
Change value,
7.26
Operating machine via joystick
7.26.1
Auxiliary functions (AUX)
There are terminals which support the additional function “Auxiliary” (AUX). By means of this
function, programmable keys of peripheral equipment (e.g. joystick) can be assigned with
functions of the connected job computers. A programmable key can be assigned with several
different functions. If key assignments are saved, the display shows corresponding menus when
switching on the terminal.
The following functions are available in the “Auxiliary” (AUX) menu:
auxiliary
Function
Raise blade cassette
Lower blade cassette
Increase baling pressure/baling force