Malfunctions - Causes and Remedies
368
Pos: 160.49 /BA/Störungen - Ursachen und Behebung/Gr oß packenpr essen/Stör ung en-Ursachen-Behebung Doppel knoter T10 @ 25\mod_1242042811416_78.docx @ 249692 @ @ 1
No
.
Malfunction
Cause and/or remedy
12 Shear screw on the needle connecting rod
breaks frequently. As a result the needle
yoke stops.
Cause:
Strong wear of the twine guide eyes.
Remedy:
Exchange the twine guide eyes (1) and replace the shear
screw (2) on the needle connecting rod.
13 The baler can no longer be operated via the
terminal.
Cause:
Faulty operation or faulty connection for
operation.
Remedy:
Unscrew the terminal cable from the socket (1) located to
the left (as seen in direction of travel) on the metal cover
close to the flywheel.
Connect the plug for emergency mode (2) to the socket
(1). After 10 seconds, emergency mode is activated with
the following settings:
• Old nominal length
• Automatic mode
• Last target force to be set
Pos: 160.50 /Layout M odul e /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1