304 Troubleshooting by failure code, Part 4
Failure code [DW45KB] Swing Brake Sol Short Circuit
40-304
42
PC200, 200LC, 220, 220LC-8M0
SEN06136-00
Failure code [DW45KB] Swing Brake Sol Short Circuit
Action
level
Failure code
Failure
Swing Brake Solenoid Short Circuit
(Pump controller system)
L03
DW45KB
Detail of failure
q
Abnormal current flows when pump controller drives swing holding brake solenoid, so pump con-
troller determines that short circuit exists in swing holding brake solenoid circuit.
Action of con-
troller
q
Stops driving swing holding brake solenoid.
q
Even if cause of failure disappears, machine does not become normal until starting switch is turned
to OFF position.
Problem on
machine
q
Upper structure does not swing (swing holding brake is not released).
Related infor-
mation
q
If solenoid and wiring harness are normal, swing operation is possible by setting swing brake can-
cel switch to RELEASE position. (However, swing holding brake is not released while upper struc-
ture is stopped. swing holding brake continues to be applied.)
q
Keep swing lock switch in OFF position and swing brake cancel switch in RELEASE position during
troubleshooting. When starting switch is turned to ON position in this condition, normally current
can flow in swing holding brake solenoid circuit and brake can be released.
q
Controller command (ON/OFF) to swing holding brake solenoid can be checked with monitoring
function. (Code: 02300 Solenoid 1)
q
Method of reproducing failure code: Turn starting switch to ON position.
q
swing holding brake solenoid circuit is powered from pin (101) of pump controller connector C02 or
pin (1) of fuse box F01.
Cause
Procedure, measuring location, criteria and remarks
1
Blown fuse No. 1 (right top fuse) in
fuse box F01
Even if fuse is blown, perform troubleshooting according to following steps to
identify cause.
2
Defective swing holding brake
solenoid
1. Turn starting switch to OFF position.
2. Disconnect connector V03, and connect T-adapters to male side.
Between V03 (male) (1) and (2)
Resistance
20 to 60
z
Between V03 (male) (1) and ground
Resistance
Min. 1 M
z
3 Defective diode array D01 or D03
1. Turn starting switch to OFF position.
2. Remove diode arrays D01 and D03, and connect T-adapters to each male
side.
a
Check the continuity in diode range.
Between D01 (male) (3) (+) and (7) (-)
No continuity
Between D01 (male) (7) (+) and (3) (-)
Continuity
Between D03 (male) (3) (+) and (7) (-)
No continuity
Between D03 (male) (7) (+) and (3) (-)
Continuity
4
Ground fault in wiring harness
(contact with ground circuit)
1. Turn starting switch to OFF position.
2. Remove fuse No.1 (right top, 10 A) in fuse box F01 and diode D01.
3. Disconnect connectors C02, D01 and V03.
4. Connect T-adapters to female sides of connectors C02 and D01.
Between C02 (female) (101) and ground
Resistance
Min. 1 M
z
Between D01 (female) (3) and ground
Resistance
Min. 1 M
z
5 Short circuit in wiring harness
1. Turn starting switch to OFF position.
2. Remove fuse No.1 (right top, 10 A) in fuse box F01 and diode D01.
3. Disconnect connector C02.
4. Connect T-adapters to female sides of connectors D01 and C02.
a
Check the swing lock switch OFF position.
Between D01 (female) (3) and C02 (female) (115)
or (117) or (120)
a
Swing brake solenoid coil resistance.
Resistance
20 to 60
z
6 Defective pump controller
If no failure is found by above checks, pump controller is defective. (Since this
is an internal defect, troubleshooting cannot be performed.)
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...