SEN06136-00
PC200, 200LC, 220, 220LC-8M0
40-304
17
304 Troubleshooting by failure code, Part 4
Failure code [DHSCMA] Arm Dump PPC Press Sensor Abnormality
Circuit diagram related to arm out PPC pressure sensor
Cause
Procedure, measuring location, criteria and remarks
5
Hot short circuit in wiring harness
(contact with 5 V/24 V circuit)
1. Turn starting switch to OFF position.
2. Disconnect connector P08.
3. Connect T-adapters to female side of connector P08.
4. Turn starting switch to ON position.
Between P08 (female) (2) and ground
Voltage
Max. 1 V
6 Defective pump controller
If no failure is found by above checks, pump controller is defective.
(Since this is an internal defect, troubleshooting cannot be performed.)
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...