SEN06127-00
30-101
8
PC200, 200LC, 220, 220LC-8M0
101 Testing and adjusting, Part 1
Testing engine speed
Testing engine speed
1
a
Measure the engine speed with the monitoring
function of the machine monitor.
a
Measure the engine speed under the following
condition.
q
Engine coolant temperature: Within oper-
ating range
q
Hydraulic oil temperature: Within operat-
ing range
1.
Preparation work
Operate the machine monitor so that the
engine speed can be monitored.
a
For the operating method of the machine
monitor, see Special functions of machine
monitor.
a
Monitoring code: 01002 Engine speed
2.
Measuring low idle speed
1)
Start the engine and set the fuel control
dial in the low idle (MIN) position.
2)
Set all the levers and pedals for work
equipment control, swing control, and
travel in neutral and measure the engine
speed.
3.
Measuring high idle speed
1)
Start the engine and set the fuel control
dial in the high idle (MAX) position.
2)
Set the working mode in the power mode
(P) and turn the auto-decelerator OFF.
3)
Set all the levers and pedals for work
equipment control, swing control, and
travel in neutral and measure the engine
speed.
4.
Measuring 2-pump relief speed
1)
Start the engine and operate the arm cyl-
inder to the IN stroke end.
2)
Set the fuel control dial in the high idle
(MAX) position and set the working mode
in the power mode (P).
3)
Operate the left work equipment control
lever to relieve the arm circuit at the IN
stro ke e nd and m easu re the eng in e
speed.
5.
Measuring 2-pump relief and power maxi-
mizing speed (near rated speed)
1)
Start the engine and operate the arm cyl-
inder to the IN stroke end.
2)
Set the fuel control dial in the high idle
(MAX) position and set the working mode
in the power mode (P).
3)
While operating the left work equipment
control lever to relieve the arm circuit at
the IN stroke end and depressing the
power maximizing switch, measure the
engine speed.
a
The power maximizing function is reset
automatically in approximately 8.5 sec-
onds even if the switch is kept depressed.
Accordingly, measure the engine speed in
that period.
a
You may check with the swing lock switch
ON (In this case, you do not need to oper-
ate the power maximizing switch.)
6.
Measuring auto-deceleration speed
1)
Start the engine, set the fuel control dial in
the high idle position (MAX), and turn the
auto-decelerator ON.
2)
Set all the levers and pedals for work
equipment control, swing control, and
travel in neutral and measure the engine
speed when the auto-decelerator oper-
ates.
a
The engine speed lowers to a certain level
approximately 5 seconds after all the
levers and pedals are set in neutral. This
level is the auto-deceleration speed.
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...