SEN06151-00
PC200, 200LC, 220, 220LC-8M0
80-100
31
100 Air conditioner
Testing with self-diagnosis function
Testing with self-diagnosis function
Testing outline
The air conditioner controller performs various
self-diagnosis such as sunlight sensor, inside air
temperature sensor, outside air temperature sen-
sor, evaporator temperature sensor, temperature
control system, vent (mode) changeover system,
and refrigerant pressure with the pressure switch. If
an error is detected on the temperature control sys-
tem, vent (mode) changeover system, or refrigerant,
the machine monitor momentarily shows "L01" (2)
and then "Air conditioner system state monitor" is
displayed continuously.
a
The machine monitor displays the system state
monitor "!" when an error occurs in the commu-
nication between the machine monitor and the
air conditioner controller.
a
Even if the cause of a detected problem is re-
stored to normal, the self-diagnosis failure condi-
tion will not automatically be reset. To reset the
failure condition, the starter switch must be set to
OFF.
a
On the "Electrical System" screen in the service
mode of the machine monitor, the system per-
forms self-diagnosis for various sensors. If a
problem is detected, failure information is dis-
played.
a
FRESH/RECIRC air changeover servomotor is
not checked with self-diagnosis function.
How to enter air conditioner "Electrical Sys-
tems" screen in service mode of the machine
monitor.
q
Overview of machine monitor operating pro-
cedure
Normal screen
O
While pressing number key (4), press (1), (2),
and (3) in this order.
Service menu (Mode)
O
Press [F3] twice. Press [F6].
03 Abnormality record
O
Press [F3] once. Press [F6].
02 Electrical Systems screen
q
Detailed description of machine monitor op-
erating procedure
1. On the normal operation screen, while pressing
number key (4), press (1), (2), and (3) in this
order.
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...