SEN06127-00
30-101
36
PC200, 200LC, 220, 220LC-8M0
101 Testing and adjusting, Part 1
Testing and adjusting oil pressure in work equipment,
1.
Adjusting work equipment and travel relief
pressure
a
If the relief pressure of the work equip-
ment circuit and travel circuit is abnormal,
adjust main relief valves (3) and (4)
according to the following procedure.
q
(3): Front (F) main relief valve
q
(4): Rear (R) main relief valve
a
When adjusting the main relief valves,
remove the top cover of the control valve.
a
Adjust only the low relief pressure of the
main relief valve. If the low repair proce-
dure is adjusted, the high repair procedure
is set automatically.
a
The low relief pressure is the pressure
applied when the 2-stage relief solenoid
valve is turned OFF and the pilot pressure
is not applied to the selector port.
1)
Disconnect pilot hose (5).
2)
While fixing holder (6), loosen locknut (7).
3)
Turn holder (6) to adjust the set pressure.
a
If the holder is
q
Turned to the right, the set pres-
sure is increased.
q
Turned to the left, the set pres-
sure is decreased.
a
Quantity of adjustment per turn of
holder:
Approx. 20.5 MPa
{Approx. 209 kg/cm
2
}
4)
While fixing holder (6), tighten locknut (7).
3
Locknut:
49 to 58.8 Nm {5 to 6 kgm}
5)
Connect pilot hose (5).
6)
After finishing adjustment, check again
that the oil pressure is normal according to
the above described measurement proce-
dure.
2.
Adjusting swing relief pressure
a
If the swing relief pressure is abnormal,
adjust safety valve (8) of the swing motor
according to the following procedure.
1)
While fixing adjustment screw (9), loosen
locknut (10).
2)
Turn adjustment screw (9) to adjust the
pressure.
a
If the adjustment screw is
q
Turned to the right, the set pres-
sure is increased.
q
Turned to the left, the set pres-
sure is decreased.
a
Quantity of adjustment per turn of
adjustment screw:
Approx. 6.7 MPa
{Approx. 68.4 kg/cm
2
}
3)
While fixing adjustment screw (9), tighten
locknut (10).
3
Locknut:
78 to 103 Nm {8 to 10.5 kgm}
4)
After finishing adjustment, check again
that the oil pressure is normal according to
the above described measurement proce-
dure.
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...