![Komatsu PC200-8M0 Shop Manual Download Page 1195](http://html1.mh-extra.com/html/komatsu/pc200-8m0/pc200-8m0_shop-manual_19912291195.webp)
SEN06151-00
PC200, 200LC, 220, 220LC-8M0
80-100
37
100 Air conditioner
Testing relays
Testing relays
a
If the air conditioner compressor is normal (air is
cooled), omit this test since the relays are nor-
mal.
q
Compressor clutch relay R21:
Turns the air conditioner compressor (clutch)
ON/OFF.
a
See Step 2 on "Parts and connectors layout".
Testing
1. Check contact R21 of connector (for disconnec-
tion).
2. Turn the starting switch ON (do not start the
engine), turn the main power of the air condi-
tioner ON, and turn the air conditioner switch. If
the compressor relay is normal, it is turned ON.
Check whether its clicks.
a
The air conditioner controller will not turn on
the compressor clutch relay in the following
cases.
1) When the evaporator temperature is below
3 °C (depending on the input voltage from
the evaporator temperature sensor).
2) When the dual pressure switch detects
abnormality (it is turned OFF).
q
Checking relay unit
a
Since no T-adapter is available, it is impossible
to check the relay while the voltage is applied to
the coil actually.
Compressor clutch relay (RLCC), connector (R21)
1) The coil resistance between terminals (1)
and (2) is approximately 300 to 500
z
.
2) While voltage (DC 20 to 30 V) is not applied
between terminals (1) (+) and (2), terminals
(3) and (4) are connected.
3) While voltage (DC 20 to 30 V) is applied
between terminals (1) (+) and (2), terminals
(3) and (5) are connected.
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...