SEN06138-00
PC200, 200LC, 220, 220LC-8M0
40-400
37
400 Troubleshooting of electrical system (E-mode)
E-20 Any of work equipment, swing and travel do not operate or cannot be locked
E-20 Any of work equipment, swing and travel do not operate or cannot
be locked
Failure
1) All of work equipment, swing, and travel mechanism do not move.
Related infor-
mation
Cause
Procedure, measuring location, criteria and remarks
1 Defective fuse F01-3
If fuse is blown, circuit probably has grounding fault. (See Cause 6.)
2
Defective lock lever
switch (internal open cir-
cuit)
1. Turn starting switch to OFF position.
2. Disconnect connector S14 and connect T-adapters to female side.
Between S14 (male) (1) and
(2)
Lock lever: LOCK
Resistance
Min. 1 M
z
Lock lever: FREE
Resistance
Max. 1
z
3
Defective PPC lock sole-
noid (open or short circuit
in internal wiring)
1. Turn starting switch to OFF position.
2. Disconnect connector V01 and connect T-adapters to male side.
Between V01 (male) (1) and (2)
Resistance
20 – 60
z
Between V01 (male) (1) and ground
Resistance
Min. 1 M
z
4
Defective diode array D01
(Internal short circuit)
1. Turn starting switch to OFF position.
2. Remove diode array D01 and connect T-adapters to male side.
a
Check the continuity in diode range.
Between D01 (male) (8) (+) and (4) (-)
Continuity
Between D01 (male) (4) (+) and (8) (-)
No continuity
5
Open circuit in wiring har-
ness
(wire breakage or defec-
tive contact of connector)
1. Turn starting switch to OFF position.
2. Set lock lever to FREE position.
3. Remove fuse F01-3.
Between F01-3 and ground (coil resistance of PPC lock
solenoid)
Resistance
20 – 60
z
a
If no failure is found by above check, this check is not required.
1. Turn starting switch to OFF position.
2. Remove fuse F01-3.
3. Disconnect connectors S14 and V01 and then connect T-adapters to male side of
S14 and female side of V01.
Between F01-3 and S14 (male) (1)
Resistance
Max. 1
z
Between S14 (male) (2) and V01 (female) (1)
Resistance
Max. 1
z
Between V01 (female) (2) and ground (T09)
Resistance
Max. 1
z
6
Ground fault in wiring har-
ness
(contact with ground cir-
cuit)
1. Turn starting switch to OFF position.
2. Remove fuse F01-3.
3. Disconnect connectors S14, V01, and D01, and then connect T-adapters to male
side of S14 or female side of V01 or D01.
Between ground and F01-3 or S14 (male) (1)
Resistance
Min. 1 M
z
Between ground and S14 (male) (2), V01 (female) (1) or
D01 (female) (4)
Resistance
Min. 1 M
z
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...