304 Troubleshooting by failure code, Part 4
Failure code [DHSAMA] Swing RH PPC Press Sensor Abnormality
40-304
12
PC200, 200LC, 220, 220LC-8M0
SEN06136-00
Failure code [DHSAMA] Swing RH PPC Press Sensor Abnormality
Action
level
Failure code
Failure
Swing Right PPC Pressure Sensor Abnormality
(Pump controller system)
L01
DHSAMA
Detail of failure
q
Signal voltage of swing RIGHT PPC pressure sensor is below 0.3 V or above 4.5 V.
Action of con-
troller
q
Controls machine taking it that swing RIGHT PPC pressure is 0 MPa {0 kg/cm
2
}.
q
If cause of failure disappears, machine becomes normal by itself.
Problem on
machine
q
Automatic deceleration does not cancel.
q
Controllability of swing RIGHT deteriorates.
Related infor-
mation
a
If 5 V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor
will be broken. Accordingly, take extreme care when checking.
q
As T-adapter for pump controller connector is "socket-type box", operating voltage cannot be mea-
sured at pump controller connector.
q
Swing RIGHT PPC pressure can be checked with monitoring function.
(Code 09002: Swing RIGHT PPC pressure)
q
Method of reproducing failure code: Turn starting switch to ON position or start engine.
Cause
Procedure, measuring location, criteria and remarks
1
Defective 5V sensor power supply
1 system
If failure code [
DA25KP
] is also displayed, perform troubleshooting for it first.
1. Turn starting switch to OFF position.
2. Disconnect connector P07, and connect T-adapters to female side.
3. Turn starting switch to ON position.
a
If power supply voltage is abnormal, proceed to check on cause 3.
Between P07 (female) (3) and (1)
Power sup-
ply
Voltage
4.5 to 5.5 V
2
Defective swing RIGHT PPC pres-
sure sensor (internal defect)
1. Turn starting switch to OFF position.
2. Connect T-adapters to connector P07.
3. Turn starting switch to ON position.
Between P07 (2) and (1)
Sensor out-
put
Voltage
0.5 to 4.5 V
a
If power supply voltage is normal and sensor output voltage is abnormal, it
is difficult to judge whether cause of failure is defective sensor, ground fault
or hot short circuit in wiring harness. Check as below.
1. Turn starting switch to OFF position.
2. Replace connector P07 with connector of other PPC pressure sensor.
3. Turn starting switch to ON position and display "Abnormality Record"
screen of electrical system on machine monitor.
4. If E mark is not displayed for this failure code, swing RIGHT PPC pressure
sensor is defective.
a
After finishing test, restore connectors.
3
Open circuit in wiring harness
(wire breakage or defective con-
tact of connector)
1. Turn starting switch to OFF position.
2. Disconnect connectors C01 and P07, and connect T-adapters to each
female side.
a
If power supply voltage measured in check on
cause 1 is normal, this check is not required.
Between C01 (female) (18) and P07 (female) (1)
Resistance
Max. 1
z
Between C01 (female) (72) and P07 (female) (2)
Resistance
Max. 1
z
a
If power supply voltage measured in check on
cause 1 is normal, this check is not required.
Between C01 (female) (9) and P07 (female) (3)
Resistance
Max. 1
z
4
Ground fault in wiring harness
(contact with ground circuit)
1. Turn starting switch to OFF position.
2. Disconnect connectors C01 and P07, and connect T-adapters to either
female side.
Between ground and C01 (female) (72) or P07
(female) (2)
Resistance
Min. 1 M
z
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...