400 Troubleshooting of electrical system (E-mode)
E-2 Preheater does not operate
40-400
14
PC200, 200LC, 220, 220LC-8M0
SEN06138-00
Cause
Procedure, measuring location, criteria and remarks
8
Ground fault in wiring harness
(contact with ground circuit)
a
If no failure is found by check on cause 3, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors H15 and CM01, terminals R15 and E01, and
starting motor terminal B.
Between heater relay terminal R15 (wiring harness
side) and ground
Resistance
Min. 1 M
z
Between input terminal on contact side of heater
relay and ground
Resistance
Min. 1 M
z
Between heater relay terminal E01 (wiring harness
side) and ground
Resistance
Min. 1 M
z
Failure
2) Automatic preheating does not function.
Related informa-
tion
q
Automatic preheating starts when boost temperature is below -4 °C.
(Monitoring code Boost temperature: 18500)
q
If automatic preheating does not function, check if manual preheating functions.
q
Engine controller checks primary (coil) side of preheater relay (connector R18) and generates fail-
ure codes [
CA2555
] and [
CA2556
] if it is defective.
q
Engine controller checks boost temperature sensor and generates failure codes [
CA153
] and
[
CA154
] if it is defective.
Cause
Procedure, measuring location, criteria and remarks
1
Defective fuse No. 6 in fuse
box F01
If fuse No. 6 in fuse box 01 is broken, circuit probably has ground fault. In this case,
perform troubleshooting for cause 5 first.
2
Defective auto preheater
relay R18 (open or short cir-
cuit in internal wiring)
1. Turn starting switch to OFF position.
2. Replace auto preheater relay (connector R18) with horn relay (connector R08),
for example.
3. Turn starting switch to ON position.
If automatic preheater operates when charged (boosted) air temperature is below
-4 °C, original auto preheater relay is defective.
3
Open circuit or ground fault in
wiring harness
1. Turn starting switch to OFF position.
2. Disconnect connectors CM01 and R18, and connect T-adapter to female side of
R18.
a
If resistance is above 1 M
z
, wiring harness has open circuit. If resistance is be-
low 1
z
, wiring harness has short circuit.
a
Heater relay coil resistance
Between R18 (female) (5) and ground
Resistance Approx. 20
z
4
Open circuit in wiring har-
ness
(Wire breakage or defective
contact)
1. Turn starting switch to OFF position.
2. Disconnect connectors R18 and CM01, and connect T-adapters to female side
of R18.
3. Remove fuse No. 6 in fuse box F01.
Between R18 (female) (3) and F01-6
Resistance
Max. 1
z
Between R18 (female) (5) and heater relay terminal
R15
Resistance
Max. 1
z
5
Ground fault in wiring har-
ness
(contact with ground circuit)
If fuse is not blown, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors CM01, R18, and starting motor terminal B, and connect
T-adapter to female side of R18.
Between R18 (female) (3) and ground
Resistance
Min. 1 M
z
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...