305 Troubleshooting by failure code, Part 5
Failure code [DXE5KB] Merge-divide Main Sol Short Circuit
40-305
34
PC200, 200LC, 220, 220LC-8M0
SEN06137-00
Failure code [DXE5KB] Merge-divide Main Sol Short Circuit
Action
level
Failure code
Failure
Merge-divide Main Solenoid Short Circuit
(Pump controller system)
L01
DXE5KB
Detail of failure
q
When pump merge-divider (main) EPC solenoid is driven, abnormal current flows and short circuit
is detected.
Action of con-
troller
q
Stops outputting current to merge-divider (main) EPC solenoid. (Since no current flows, merge-
divider LS solenoid does not operate, either.)
q
Even if cause of failure disappears, machine does not become normal until starting switch is turned
to OFF position.
Problem on
machine
q
Single operation speed of work equipment and swing is high in fine control mode (L).
q
Machine does not turn easily during travel.
Related infor-
mation
q
Drive current to merge-divider main EPC solenoid can be checked with monitoring function.
(Code: 08000 Merge-divider (main) solenoid current)
q
Method of reproducing failure code: Turn starting switch to ON position.
Cause
Procedure, measuring location, criteria and remarks
1
Defective merge-divider main EPC
solenoid (internal short circuit or
ground fault)
1. Turn starting switch to OFF position.
2. Disconnect connector V23, and connect T-adapters to male side.
Between V23 (male) (1) and (2)
Resistance
3 to 14
z
Between V23 (male) (1) and ground
Resistance
Min. 1 M
z
2
Short circuit or ground fault in wir-
ing harness
1. Turn starting switch to OFF position.
2. Disconnect connector C02 and connect T-adapters to female side.
Between C02 (female) (112) and each of (115),
(117) and (120)
Resistance
3 to 14
z
Between C02 (female) (112) and ground
Resistance
Min. 1 M
z
3
Ground fault in wiring harness
(contact with ground circuit)
a
If no failure is found by check on cause 2, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors C02 and V23, and connect T-adapters to either
female side.
Between C02 (female) (112) or V23 (female) (1)
and ground
Resistance
Min. 1 M
z
4 Defective pump controller
If no failure is found by above checks, pump controller is defective. (Since this
is an internal defect, troubleshooting cannot be performed.)
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...