SEN06128-00
30-102
16
PC200, 200LC, 220, 220LC-8M0
102 Testing and adjusting, Part 2
Special functions of machine monitor
a
Actions to take given by action levels to opera-
tor (Excerpt from the Operation and Mainte-
nance Manual)
Function of checking display of LCD (Liquid
Crystal Display)
While the standard screen is displayed, if the
numeral input switches or function switches are
operated in the following manner, the entire LCD
screen turns white.
q
Switch operations (simultaneous): [4] + [F2]
a
When finishing the operation of the switches,
release [F2] first.
a
If there is a display error in the LCD, only that
part is indicated in black.
a
To return to the former screen, press any one
of the function switches.
Reference: An LCD panel, as one of its characteris-
tics, sometimes shows black spots (spots that
remain unlit) and bright spots (spots that do not go
off).
If the number of the bright points and black points
does not exceed 10, the LCD panel is not faulty or
defective.
Function of checking service meter
When checking the service meter with the starting
switch in the OFF position, operate the numeral
input switches as follows to display only the service
meter section.
q
Switch operations (simultaneous): [4] + [1]
a
There is some time lag in start of the LCD, so
hold down the switches until the service meter
is displayed.
a
If you release one of the switches, the monitor
goes off.
Reference: After the machine monitor is used con-
tinuously over a long period of time, blue points
(points that remain lit) may appear on this screen. It
does not indicate that the LCD panel is faulty or
defective.
Degree
of emer-
gency
Action
level
Buzzer
Alarm
monitor
Remedy
High
L04
Q
(Con-
tinu-
ous)
Q
Stop immediately
and perform
checking and
maintenance.
Ask your Komatsu
distributor for test-
ing and repair ser-
vices.
I
L03
Q
(Inter-
mittent)
Q
Stop work, move
machine to safe
place, stop it, and
perform checking
and maintenance.
Ask your Komatsu
distributor for test-
ing and repair ser-
vices.
L02
Q
(Inter-
mittent)
Q
Stop work, and
then run the
engine at medium
speed with no
load, or stop it. If
the condition does
not improve, ask
your Komatsu dis-
tributor for testing
and repair ser-
vices.
Low
L01
(For 2
seconds
only)
—
Q
Some functions
are restricted, but
the machine can
work. After finish-
ing work, perform
checking and
maintenance.
Ask your Komatsu
distributor to per-
form testing or
repairs as neces-
sary.
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...