SEN06123-00
10-600
44
PC200, 200LC, 220, 220LC-8M0
600 Electrical system
Machine monitor system
(*1)
Water separator
When
abnormal
(There is water
collected
above the
specified
amount.)
Lights up (Red)
—
• When failure is detected with
the engine running, the
monitor lights up on the
screen.
When normal
Lights off
—
Maintenance
interval warning
When
exceeding
maintenance
interval
Lights up (Red)
—
• The display changes
depending on the time to/
after the maintenance.
• After the starting switch is
turned to ON position , the
monitor turns on if the
monitor light-up conditions
are met, and then goes out in
30 seconds.
(*2)
When
exceeding
maintenance
notifying time
Lights up
(Yellow)
—
System status
When action
level “L04” or
“L03” is
detected
Lights up (Red)
L04 and L03
• When failure is detected in
the machine system, the
monitor lights up.
• When the background color
is red, the alarm buzzer
sounds.
When action
level “L01” is
detected
Lights up
(Yellow)
(*3)
L01
State of engine
system
When action
level “L04” or
“L03” is
detected
Lights up (Red)
L04 and L03
• When failure is detected in
the engine system, the
monitor lights up.
• When the background color
is red, the alarm buzzer
sounds.
When action
level “L01” is
detected
Lights up
(Yellow)
(*3)
L01
State of hydraulic
system
When action
level “L04” or
“L03” is
detected
Lights up (Red)
L04 and L03
• When failure is detected in
the hydraulic system, the
monitor lights up.
• When the background color
is red, the alarm buzzer
sounds.
When action
level “L01” is
detected
Lights up
(Yellow)
(*3)
L01
Engine
overspeed
Engine
overspeed is
detected
Lights up (Red)
L02
• The monitor lights up and
alarm buzzer sounds when
engine overspeed is
detected.
Sate of air
conditioner
system
When air
conditioner is
abnormal
Lights up
(Yellow)
(*3) L01
• When failure is detected in
the air conditioner system,
the monitor lights up.
Symbol
Display item
Description
Remarks
Range
Monitor display
(Background
color)
Action level
monitor
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...