302 Troubleshooting by failure code, Part 2
Failure code [CA352] Sens Supply 1 Volt Low Error
40-302
18
PC200, 200LC, 220, 220LC-8M0
SEN06134-00
Failure code [CA352] Sens Supply 1 Volt Low Error
Action
level
Failure code
Failure
Sensor Power supply 1 Voltage Low Error
(Engine controller system)
L03
CA352
Detail of failure
q
Low voltage appears in sensor power supply 1 circuit.
Action of con-
troller
q
Takes ambient pressure to be at fixed value and allows engine to run.
Problem on
machine
q
Engine output lowers.
q
Engine starting performance becomes deteriorated.
Related infor-
mation
q
Method of reproducing failure code: Turn starting switch to ON position.
Cause
Procedure, measuring location, criteria and remarks
1
Defective wiring harness connec-
tor
See descriptions of wiring harness and connectors in "c: Electrical equipment"
in "Checks before troubleshooting" of "General information on troubleshoot-
ing", and check them.
2 Defective sensor or wiring harness
1. Turn starting switch to OFF position.
2. Disconnect following connectors one by one and turn starting switch to ON
position each time.
3. After each troubleshooting, return to step 1.
If this failure code is not displayed when a sensor is disconnected, sensor or
engine wiring harness is defective.
a
Other failure codes are displayed as well. This is because of disconnection
of connector. Ignore all failure codes other than [
CA352
].
Sensor or harness
Connector
Ambient pressure sensor
AMB. AIR PRESSURE
Engine wiring harness
ECM
3 Defective engine controller
1. Turn starting switch to OFF position.
2. Disconnect connector ECM and connect T-adapters to male side.
3. Turn starting switch to ON position with connector ECM disconnected.
Between ECM (male) (33) and (38)
Voltage
4.75 to 5.25V
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...