SEN06127-00
30-101
26
PC200, 200LC, 220, 220LC-8M0
101 Testing and adjusting, Part 1
Bleeding air from fuel circuit
7)
Start the engine. By using measuring cyl-
inder G4, measure the return rate from the
injector for 1 minute with the engine speed
at low idle.
a
You may make the measurement for
20 seconds and multiply the mea-
sured result by 3.
a
If the return rate from the supply
pump is within the following standard
range, it is normal.
k
If you cannot start the engine, you
may measure the return rate with
the engine cranked with the start-
ing motor. However, for protection
of the starting motor, do not keep
cranking continuously for 20 sec-
onds or longer.
8)
Remove the tools after finishing measur-
ing. Be sure to restore the machine.
3
Joint bolt:
19.6 to 29.4 Nm {2.0 to 3.0 kgm}
Bleeding air from fuel circuit
1
a
If fuel is used up or if a fuel circuit part is
removed and installed, bleed air from the fuel
circuit according to the following procedure.
k
Stop the machine on a level ground and
lower the work equipment to the ground.
1.
Fill up fuel tank with fuel.
a
Add fuel until the float of the sight gauge
reaches the maximum position.
2.
Open the side cover of the pump room.
3.
Loosen knob (1) of the feed pump and pull it
out, and then operate it forward and backward.
a
Move the knob until it becomes heavy.
a
The plug at the top of the fuel main filter
does not need to be removed.
a
After bleeding air, some air may be left in
the water separator. If the feed pump is
operated until it becomes heavy, however,
the engine can be started. The remaining
air is bled naturally while the engine is run-
ning for a while. This phenomenon occurs
when the fuel in the fuel prefilter is drained
too much and does not indicate an abnor-
mality or a trouble.
4.
After bleeding air, push in and tighten knob (1).
Low idle
Max. 180 cc
Cranking
Max. 90 cc
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...