
SEN06138-00
PC200, 200LC, 220, 220LC-8M0
40-400
39
400 Troubleshooting of electrical system (E-mode)
E-21 Swing holding brake does not operate properly
E-21 Swing holding brake does not operate properly
Failure
1) When swing brake cancel switch is set to CANCEL position, machine cannot swing.
Related infor-
mation
q
Signal of swing lock switch can be checked with monitoring function.
(Pump controller system code: 02200 Switch input 1)
Cause
Procedure, measuring location, criteria and remarks
1 Defective fuse F01-1
If fuse F01-1 is broken, circuit probably has ground fault. In this case, perform trou-
bleshooting for cause 6 first.
2
Defective swing brake can-
cel switch (internal short cir-
cuit)
1. Turn starting switch to OFF position.
2. Disconnect connector S25 and connect T-adapters to male side.
Between S25 (male) (13)
and (14)
swing brake cancel switch:
Normal
Resistance
Min. 1 M
z
swing brake cancel switch:
FREE
Resistance
Max. 1
z
3
Defective diode array D01 or
D03 (internal short circuit)
1. Turn starting switch to OFF position.
2. Remove diode arrays D01 and D03, and connect T-adapters to male side.
a
Check the continuity in diode range.
Between D01 (male) (7) (+) and (3) (-)
Continuity
Between D01 (male) (3) (+) and (7) (-)
No continuity
Between D03 (male) (7) (+) and (3) (-)
Continuity
Between D03 (male) (3) (+) and (7) (-)
No continuity
4 Defective wiring harness
1. Turn starting switch to OFF position.
2. Disconnect connector V03 and connect T-adapters to female side.
3. Turn starting switch to ON position.
Between V03 (female) (1)
and (2)
swing brake cancel switch:
FREE
Voltage
20 to 30 V
swing brake cancel switch:
Normal
Voltage
Max. 1 V
5
Open circuit in wiring har-
ness
(wire breakage or defective
contact of connector)
a
If no failure is found by check on cause 4, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors V03 and S25 and connect T-adapters to each male side.
Between V03 (female) (1) and S25 (female) (14)
Resistance
Max. 1
z
Between V03 (female) (2) and C02 (female) (115)
Resistance
Max. 1
z
6
Ground fault in wiring har-
ness
(contact with ground circuit)
a
If no failure is found by check on cause 3, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors S25, V03, D01 and D03, and connect T-adapters to
female side of V03.
Between V03 (female) (1) and ground
Resistance
Min. 1 M
z
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...