301 Troubleshooting by failure code, Part 1
Failure code [AB00KE] Charge Voltage Low
40-301
10
PC200, 200LC, 220, 220LC-8M0
SEN06133-00
Failure code [AB00KE] Charge Voltage Low
Action
level
Failure code
Failure
Charging voltage low
(Machine monitor system)
L03
AB00KE
Detail of failure
q
While engine is running, voltage from alternator drops, and machine monitor detects that battery
charge voltage is low (below 7.8 V).
Action of
machine moni-
tor
q
Displays charge level monitor red on machine monitor.
q
Even if cause of failure disappears, machine does not become normal until starting switch is turned
to OFF position.
Problem on
machine
q
If machine is operated as it is, battery may not be charged.
Related infor-
mation
q
Signal voltage from alternator can be checked with monitoring function.
(Code: 04300 Charge voltage)
q
Method of reproducing failure code: Start engine.
Cause
Procedure, measuring location, criteria and remarks
1
Loose alternator terminal or open
circuit at terminal
1. Turn starting switch to OFF position.
2. Check terminal.
2
Defective generation by alternator
(when system is normal)
1. Turn starting switch to OFF position.
2. Insert T-adapters into connector E12.
3. Start engine.
Between E12 (1) and
ground
Engine speed: Medium
or higher
Voltage
27.5 to 29.5 V
3 Defective diode
1. Turn starting switch to OFF position.
2. Disconnect diode D01 and connect T-adapter to male side.
a
Check the continuity in diode range.
Between D01 (male) (2) (+) and (6) (-)
No continuity
Between D01 (male) (6) (+) and (2) (-)
Continuity
4
Defective wiring harness or
machine monitor
1. Turn starting switch to OFF position.
2. Insert T-adapter into connector CM01.
3. Start engine.
Between CM01 (16) and ground
Voltage
20 to 30 V
5
Open circuit in wiring harness
(wire breakage or defective con-
tact of connector)
a
If no failure is found in checks on cause 2, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors CM01 and E12, and connect T-adapters to each
female side.
Between C0M1 (female) (16) and E12 (female) (1) Resistance
Max. 1
z
6
Ground fault in wiring harness
(contact with ground circuit)
a
If no failure is found in checks on cause 2, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors CM01 and E12, and connect T-adapter to either
female side.
Between CM01 (female) (16) or E12 (female) (1)
and ground
Resistance
Min. 1 M
z
7 Defective machine monitor
If no failure is found by above checks, machine monitor is defective.
(Since this is an internal defect, troubleshooting cannot be performed.)
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...