400 Troubleshooting of electrical system (E-mode)
E-22 One-touch power maximizing function does not operate properly
40-400
42
PC200, 200LC, 220, 220LC-8M0
SEN06138-00
E-22 One-touch power maximizing function does not operate properly
Failure
1) When L.H. knob switch is pressed, one-touch power max. monitor is not displayed.
2) When L.H. knob switch is pressed, work equipment power is not increased.
Related information
q
One-touch power max. function does not operate when selected working mode is not power
mode (P) or economy mode (E).
q
Signal of L.H. knob switch can be checked with monitoring function.
(Code: 02200 Switch Input 1)
Cause
Procedure, measuring location, criteria and remarks
1 Defective machine monitor
When L.H. knob switch is pressed, if work equipment power is increased but
one-touch power max. monitor is not displayed on machine monitor, machine
monitor may be defective. (Since this is an internal defect, troubleshooting can-
not be performed.)
2 Defective fuse No. 9
If fuse is blown, circuit probably has grounding fault. (See Cause 6.)
3
Defective left knob switch
(Internal open circuit)
1. Turn starting switch to OFF position.
2. Disconnect connector S11, and connect T-adapters to male side.
Between S11 (female) (1)
and (2)
L.H. knob switch:
Released
Resistance
Min. 1 M
z
L.H. knob switch:
Pressed
Resistance
Max. 1
z
4
Open circuit or ground fault in wir-
ing harness
1. Turn starting switch to OFF position.
2. Disconnect connector C01 and connect T-adapters to female side.
3. Turn starting switch to ON position.
a
Ignore displayed failure code.
Between C01 (female)
(41) and ground
L.H. knob switch:
Released
Voltage
Max. 1 V
L.H. knob switch:
Pressed
Voltage
20 to 30
z
5
Open circuit in wiring harness
(wire breakage or defective con-
tact of connector)
a
If no failure is found by check on cause 4, this check is not required.
1. Turn starting switch to OFF position.
2. Remove fuse F01-9.
3. Disconnect connectors C01 and S11 and connect T-adapters to each female
side.
Between F01-9 and S11 (female) (1)
Resistance
Max. 1
z
Between S11 (female) (2) and C01 (female) (41)
Resistance
Max. 1
z
6
Ground fault in wiring harness
(contact with ground circuit)
a
If no failure is found by check on cause 4, this check is not required.
1. Turn starting switch to OFF position.
2. Remove fuse F01-9.
3. Disconnect connectors C01 and S11 and connect T-adapters to female side
of S11.
Between F01-9 or S11 (female) (1) and ground
Resistance
Min. 1 M
z
Between S11 (female) (2) or C01 (female) (41) and
ground
Resistance
Min. 1 M
z
7 Defective pump controller
If no failure is found by above checks, the pump controller is defective. (Since
this is an internal defect, troubleshooting cannot be performed.)
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...