305 Troubleshooting by failure code, Part 5
Failure code [DY2DKB] Wiper Drive (Fwd) Short
40-305
46
PC200, 200LC, 220, 220LC-8M0
SEN06137-00
Failure code [DY2DKB] Wiper Drive (Fwd) Short
Action
level
Failure code
Failure
Wiper motor Drive Foward rotation Short Circult
(Pump controller system)
–
DY2DKB
Detail of failure
q
When outputting current to normal rotation side of wiper motor drive, abnormal current flows in cir-
cuit and short circuit is detected.
Action of con-
troller
q
Stops outputting current to wiper motor drive forward side.
q
Even if cause of failure disappears, machine does not become normal until starting switch is turned
to OFF position.
Problem on
machine
q
Windshield wiper does not operate.
Related infor-
mation
q
As T-adapter for pump controller connector is "socket-type box", operating voltage cannot be mea-
sured at pump controller connector.
q
Method of reproducing failure code: Turn starting switch to ON position and set wiper switch to INT
or ON.
Cause
Procedure, measuring location, criteria and remarks
1
Defective wiper motor
(internal short circuit or ground
fault)
1. Turn starting switch to OFF position.
2. Disconnect connector M05 and connect T-adapters to female side.
Between M05 (female) (3) and (1)
Continuity
Between M05 (female) (3) and ground
Resistance
Min. 1 M
z
2 Short circuit in wiring harness
1. Turn starting switch to OFF position.
2. Disconnect connectors C02 and M05 and connect T-adapter to wiring
harness side of either of them.
Between C02 (female) (119) and (114), or between
M05 (male) (1) and (3)
Resistance
Min. 1 M
z
3
Ground fault in wiring harness
(contact with ground circuit)
1. Turn starting switch to OFF position.
2. Disconnect connectors C02 and M05 and connect T-adapter to wiring
harness side of either of them.
Between C02 (female) (119) or M05 (male) (3) and
ground
Resistance
Min. 1 M
z
4 Defective pump controller
If no abnormality is found by above checks, pump controller is defective. (Since
this is an internal defect, troubleshooting cannot be performed.)
q
Reference
1. Turn starting switch to OFF position.
2. Insert T-adapters into connector M05.
3. Turn starting switch to ON position.
4. Turn wiper switch ON and OFF, and troubleshoot.
Between M05 (3) and
(5)
Wiper switch:
OFF
Voltage
Max. 3 V
Wiper switch: ON
Voltage
Pulse below 3 V
io
above 20 V
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...