SEN06112-00
00-200
8
PC200, 200LC, 220, 220LC-8M0
200 Foreword and general information
Foreword, safety and general information
q
Fire caused by piping
Check that all the clamps for the hoses and
tubes, guards, and cushions are securely fixed
in position.
If they are loose, they may vibrate during oper-
ation and rub against other parts.There is dan-
ger that this may lead to damage to the hoses
and cause high-pressure oil to spurt out, lead-
ing to fire and serious personal injury or death.
q
Fire around the machine due to highly
heated exhaust gas
T h i s m a c h i n e i s e q u i p p e d w i t h K D P F
(Komatsu Diesel Particulate Filter).
KDPF is a system for purifying soot in exhaust
gas. The exhaust gas discharged during the
purification process (regeneration) can be
higher temperature than that of existing mod-
els. Do not bring any flammable material close
to the outlet of the exhaust pipe.
q
If there are thatched houses, dry leaves or
pieces of paper around the job site, set the
system to the “Regeneration Disable”
before starting operation to prevent fire
hazard of highly heated exhaust gas
caused by KDPF regeneration.
See the operation and maintenance man-
ual for the setting procedure.
q
Explosion caused by lighting equipment
q
When checking fuel, oil, battery electro-
lyte, or coolant, always use lighting equip-
ment with anti-explosion specifications.
q
When taking the electrical power for the
lighting equipment from the machine itself,
follow the instructions in the operation and
maintenance manual.
Dispose of waste materials
To prevent pollution, pay full attention to the way to
dispose of waste materials.
q
Always put the oil and coolant drained from the
machine in containers. Never drain the oil and
coolant directly onto the ground or dump into
the sewage system, rivers, the sea, or lakes.
q
Observe the related laws and regulations when
disposing of harmful objects such as oil, fuel,
coolant, solvent, filters, and batteries.
Some kinds of rubber and plastics may produce
poisonous gas harmful to human body when they
are burned.
q
As for rubber, plastics, or parts (hoses, cables,
and wiring harnesses, etc.) which contain
those materials, ask the industrial waste treat-
ment firms for their disposals in accordance
with the local regulations.
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...