SEN06128-00
30-102
30
PC200, 200LC, 220, 220LC-8M0
102 Testing and adjusting, Part 2
Special functions of machine monitor
Abnormality Record (Mechanical Systems)
The machine monitor classifies and logs the fail-
ures which occurred in the past or which are occur-
r i n g a t p r e s e n t i n t o t h e m e c h a n i c a l s y s t e m
abnormality, and electrical system abnormality.
To check the mechanical system abnormality
record, perform the following procedures.
a
For the failure code list, see “40 Failure codes
table”.
1.
Selecting the menu
Select “Abnormality Record” on the “Service
Menu” Screen.
2.
Selecting sub menu
After the “Abnormality Record” screen is dis-
played, select “Mechanical Systems” by using
t h e f u n c t i o n s w i t c h e s o r n u m e r a l i n p u t
switches.
q
[F3]: Moves to lower item
q
[F4]: Moves to upper item
q
[F5]: Returns the display to the service
menu screen
q
[F6]: Validates the selection
a
You may enter a 2-digit code by using the
numeral input switches to select the item
of that code and enter it by using [F6].
3.
Information displayed on abnormality record
screen
On the “Mechanical Systems” abnormality
record screen, the following information is dis-
played.
(a)
: Occurrence order of abnormalities from
latest one/Total number of abnormalities in
the log
(b)
: Failure codes
(c)
: Detail of failure
(d)
: Number of occurrences (displayable
range: 0 to 65,535 times)
(e)
: Service meter reading at first occurrence
(f)
: Service meter reading at last occurrence
q
[F1]: Moves to next page (screen) (if dis-
played)
q
[F2]: Moves to previous page (screen) (if
displayed)
q
[F5]: Returns to the “Abnormality Record”
screen
a
If no failure is logged, the message of “No
Error” is displayed.
a
In the mechanical systems abnormality
record screen, up to 50 cases currently
stored are displayed.
a
If the number of occurrences is one (first
occurrence), the service meter reading at
the first occurrence and that at the last
occurrence are the same.
When the latest service meter reading is
recovered, the value at the recovery time
is displayed, thus the above readings may
not be the same.
a
If [
E
] is displayed on the left of a failure
code, the abnormality is still occurring or
restoration of it has not been confirmed.
a
For all the failure codes that the machine
monitor can record, see the “Failure codes
table”.
4.
Clearing abnormality record
A contents of the mechanical system abnor-
mality record cannot be cleared.
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...