![Komatsu PC200-8M0 Shop Manual Download Page 346](http://html1.mh-extra.com/html/komatsu/pc200-8m0/pc200-8m0_shop-manual_1991229346.webp)
SEN06125-00
20-100
16
PC200, 200LC, 220, 220LC-8M0
100 Standard service value table
Standard value table for chassis related parts
Applicable model
PC220, 220LC-8M0
Cate-
gory
Item
Measurement condition
Unit
Standard value for new
machine
Judgement criteria
W
o
rk
equipm
ent
Ti
m
e
l
a
g
Boom
• Hydraulic oil temperature: Within
operating range
• Engine running at low idle
• Working mode: P mode
• Lower boom from RAISE stroke end
and measure time from when work
equipment touches the ground until
front side of machine rises
• For measuring posture, see
Work
equipment 5
sec.
Max. 1.0
Max. 1.2
Arm
• Hydraulic oil temperature: Within
operating range
• Engine running at low idle
• Working mode: P mode
• Move arm to IN from OUT stroke
end and measure time from when
arm stops momentarily until it starts
moving again
• For measuring posture, see
Work
equipment 6
sec.
Max. 2.0
Max. 2.8
Bucket
• Hydraulic oil temperature: Within
operating range
• Engine running at low idle
• Working mode: P mode
• Move bucket to CURL from DUMP
stroke end and measure time from
when bucket stops momentarily
until it starts moving again
• For measuring posture, see
Work
equipment 7
sec.
Max. 1.0
Max. 3.6
In
te
rnal
leaka
g
e
Cylinders
• Hydraulic oil temperature: Within
operating range
• Engine running at high idle
• Leakage amount for one minute
with cylinder or travel to be
measured in relief condition
cc/min
4.5
20
Center swivel
joint
cc/min
10
50
P
e
rf
or
mance
in
c
ompound operat
ion
Travel deviation in
simultaneous
operation of work
equipment and travel
• Hydraulic oil temperature: Within
operating range
• Engine at high idle
• Working mode: P mode
• Traveling speed: Lo
• Travel deviation (x) in travel of 20 m
after running up 10 m on hard and
flat ground
• For measuring posture, see
Travel
2 and 3
mm
Max.200
Max.220
Charac
te
rist
ics of
P
C
f
lo
w
co
nt
rol
val
v
e
Time required for
turning from 0 to 90°
with boom raised
• Hydraulic oil temperature: Within
operating range
• Engine at high idle
• Working mode: P mode
• Rated load applied to bucket
(0.8m
3
: 1,440kg)
• On hard and flat ground, set arm
vertically and lower back of bucket
to ground
• Time required till passing spot of
90° starting from illustrated posture
and with boom raised
• For measuring posture, see
Work
equipment 8
sec.
4.3 ± 0.4
(Reference value)
—
Discharge amount of
hydraulic pump
See performance of hydraulic pump (next page)
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...