303 Troubleshooting by failure code, Part 3
Failure code [DA29KQ] Model Selection Abnormality
40-303
18
PC200, 200LC, 220, 220LC-8M0
SEN06135-00
Failure code [DA29KQ] Model Selection Abnormality
Action
level
Failure code
Failure
Model Selection Abnormality
(Pump controller system)
L01
DA29KQ
Detail of failure
q
Model code of input signal is not registered in controller.
Action of con-
troller
q
Controls machine, taking it that machine is default model (PC200).
q
Even if cause of failure disappears, machine does not become normal until starting switch is turned
Problem on
machine
q
Because pump controller recognizes machine as "PC200", no particular problem occurs.
Related infor-
mation
q
Model code input to pump controller can be checked by using monitoring function.
(Code: 00200 Controller model code)
q
Input of model selection signal can be checked with monitoring function.
(Code: 02201 Switch Input 2)
q
Method of reproducing failure code: Turn starting switch to ON position.
q
PC200-8M0, PC200LC-8M0
Cause
Procedure, measuring location, criteria and remarks
1
Defective model selection connec-
tor
(internal open or short circuit)
1. Turn starting switch to OFF position.
2. Disconnect connector S30 and connect T-adapters to female side.
Between S30 (female) (1) and (2)
Resistance
Min. 1 M
z
Between S30 (female) (1) and (3)
Resistance
Min. 1 M
z
Between S30 (female) (2) and (3)
Resistance
Min. 1 M
z
Between S30 (female) (3) and (4)
Resistance
Min. 1 M
z
Between S30 (female) (4) and (7)
Resistance
Min. 1 M
z
Between S30 (female) (7) and (8)
Resistance
Min. 1 M
z
Between S30 (female) (3) and (8)
Resistance
Max. 1
z
2 Open circuit in wiring harness
1. Turn starting switch to OFF position.
2. Disconnect connector C01 and connect T-adapters to female side.
Between C01 (female) (77) and ground
Resistance
Max. 1
z
3 Short circuit in wiring harness
1. Turn starting switch to OFF position.
2. Disconnect connector C01 and connect T-adapters to female side.
Between C01 (female) (21) and C01 (female) (77)
Resistance
Min. 1 M
z
Between C01 (female) (39) and C01 (77)
Resistance
Min. 1 M
z
Between C01 (female) (40) and C01 (77)
Resistance
Min. 1 M
z
Between C01 (female) (58) and C01 (77)
Resistance
Min. 1 M
z
4
Ground fault in wiring harness
(contact with ground circuit)
1. Turn starting switch to OFF position.
2. Disconnect connector C01 and connect T-adapters to female side.
Between C01 (female) (21) and ground
Resistance
Min. 1 M
z
Between C01 (female) (40) and ground
Resistance
Min. 1 M
z
Between C01 (female) (58) and ground
Resistance
Min. 1 M
z
Between C01 (female) (39) and ground
Resistance
Min. 1 M
z
5 Defective pump controller
If no failure is found by above checks, pump controller is defective. (Since this
is an internal defect, troubleshooting cannot be performed.)
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...