100 Air conditioner
Failure code [879BKB] A/C Outer sensor Short Circuit
80-100
48
PC200, 200LC, 220, 220LC-8M0
SEN06151-00
Failure code [879BKB] A/C Outer sensor Short Circuit
Action
level
Failure code
Failure
Short circuit in air conditioner outside air temperature sensor
(Machine monitor system)
–
879BKB
Detail of failure
q
Air conditioner controller detected short circuit in outside air temperature sensor.
Action of con-
troller
q
The air conditioner controller sends information about the outside air temperature sensor short cir-
cuit to the machine monitor via CAN communication.
q
Continues control of air conditioner in automatic mode, ignoring data of outside air temperature
sensor.
Problem on
machine
q
Since there is a short circuit in the air conditioner outside air temperature sensor, outside temper-
ature is not counted in automatic mode.
(does not have any effect to the air conditioner in manual mode)
Related infor-
mation
q
Method of reproducing failure code: Turn starting switch to ON position.
q
Check whether this failure code is displayed in the "Electrical Systems" (electrical systems abnor-
mality record) screen in the service mode of the machine monitor.
q
For connectors etc., see "Parts and connectors layout".
q
Since connector ACECU of the air conditioner controller has small pins and does not have a
T-adapter, perform troubleshooting by using the intermediate connector (Although the intermediate
connector does not have a T-adapter either, it does have large pins).
q
To replace the air conditioner harness between air conditioner controller connector ACECU and
intermediate controller, the air conditioner unit must be replaced.
Cause
Procedure, measuring location, criteria and remarks
1
Defective outside air temperature
sensor
1. Turn starting switch to OFF position.
2. Disconnect connector P18.
Resistance Between P18 (male) (1) and (2)
25 °C
Approx.
1.7 k
z
2
Open or short circuit in wiring har-
ness
1. Turn starting switch to OFF position.
2. Disconnect connector AC01.
a
Same as above, if resistance is normal.
Resistance Between AC01 (female) (7) and (8)
25 °C
Approx.
1.7 k
z
3 Short circuit in wiring harness
a
If no failure is found by check for cause 2, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors P18 and AC01.
Resistance
Between AC01 (female) (7) and (8), or between
P18 (female) (1) and (2)
Min. 1 M
z
4
Ground fault in wiring harness
(contact with ground circuit)
1. Turn starting switch to OFF position.
2. Disconnect connectors P18 and AC01.
Resistance
Between ground and AC01 (female) (8) or P18
(female) (1)
Min. 1 M
z
5 Defective air conditioner controller
If no failures are found by the above checks, the air conditioner controller may
be defective. (Since this is an internal defect, troubleshooting cannot be per-
formed.)
6 Defective air conditioner unit
If no failure is found by above checks, air conditioner unit may be defective.
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...