SEN06129-01
30-103
8
PC200, 200LC, 220, 220LC-8M0
103 Testing and adjusting, Part 3
Procedure for testing diodes
Procedure for testing diodes
1
a
Test the assembled-type diode (8-pin) and the
single diode (2-pin) according to the following
procedure.
a
The conductive directions of the assembled-
type diode are as follows.
a
The conductive direction of the single diode is
indicated on the surface of the diode.
1.
When using digital circuit tester
1)
Set the tester in the diode range and read
the indicated value.
a
When an ordinary circuit tester is
used, the voltage of the internal bat-
tery is indicated.
2)
Apply the red (+) lead of the tester to the
anode (P) side of the diode and apply the
black (–) lead to the cathode (N) side and
check the indicated value.
3)
Judge the condition of the diode by the
indicated value.
q
The indicated value does not change:
The diode does not have continuity
(Defective).
q
The indicated value changes:
The diode has continuity (Normal).
Note: In the case of a silicon diode, a
value in the range from 460 to 600 is indi-
cated.
2.
When using analog circuit tester
1)
Set the tester in the resistance range.
2)
Apply the leads of the tester as explained
below and check the movement of the
pointer.
i)
Apply the red (+) lead of the tester to
the anode (P) side of the diode and
apply the black (–) lead to the cath-
ode (N) side.
ii)
Apply the red (+) lead of the tester to
the cathode (N) side of the diode and
apply the black (–) lead to the anode
(P) side.
3)
Judge the condition of the diode by the
movement of the pointer.
q
The pointer does not move in i) but
moves in ii): The diode is normal (The
moving range (resistance) depends
on the type and selected range of the
tester, however).
q
The pointer moves in both i) and ii):
The diode is defective (Internal short
circuit).
q
The pointer moves in neither of i) and
ii): The diode is defective (Internal
disconnection).
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...