303 Troubleshooting by failure code, Part 3
Failure code [DGH2KB] Hyd Oil Sensor Short Circuit
40-303
40
PC200, 200LC, 220, 220LC-8M0
SEN06135-00
Failure code [DGH2KB] Hyd Oil Sensor Short Circuit
Action
level
Failure code
Failure
Hydraulic Oil Sensor Short Circuit
(Pump controller system)
L01
DGH2KB
Detail of failure
q
Signal voltage of hydraulic oil temperature sensor circuit is below 1 V, so pump controller deter-
mines that circuit shorts.
Action of con-
troller
q
If cause of failure disappears, machine becomes normal by itself.
Problem on
machine
q
Regardless of the hydraulic oil temperature, hydraulic oil temperature gauge meter is equivalent to
50 degrees.
Related infor-
mation
q
Signal voltage from hydraulic oil temperature sensor can be checked with monitoring function.
(Code: 04402: Hydraulic oil temperature sensor voltage)
q
Method of reproducing failure code: Start engine.
Cause
Procedure, measuring location, criteria and remarks
1
Defective hydraulic oil tempera-
ture sensor
(internal open or short circuit)
1. Turn starting switch to OFF position.
2. Disconnect connector P22 and connect T-adapters to male side.
Between P22 (male) (1)
and (2)
a
Temperature-Resis-
tance characteristics of
oil temperature sensor
10 °C
Resistance
Approx. 90 k
z
30 °C
Resistance
Approx. 35 k
z
80 °C
Resistance
Approx. 6.5 k
z
100 °C
Resistance
Approx. 3.5 k
z
Between P22 (male) (2) and ground
Resistance
Min. 1 M
z
2
Open circuit or short circuit or
ground fault or hot short circuit in
wiring harness
1. Turn starting switch to OFF position.
2. Disconnect connector P22 and connect T-adapters to female side.
3. Turn starting switch to ON position.
a
If voltage is 0 V, wiring harness has open circuit, ground fault, or short cir-
cuit, and if voltage is 24 V, wiring harness has hot short circuit.
a
Voltage of about 5 V is applied to temperature sensor signal lines through
resistor in pump controller.
Between P22 (female) (1) and (2)
Voltage
Approx. 5 V
3
Short circuit or ground fault in wir-
ing harness
1. Turn starting switch to OFF position.
2. Disconnect connector C01 and connect T-adapters to female side.
a
Use Temperature-Resistance characteristics table for troubleshooting on
cause 1 as resistance criteria.
a
If resistance is above 1 M
z
, wiring harness has open circuit. If resistance
is below 1
z
, wiring harness has short circuit.
Between C01 (female) (29) and (46)
Resistance
3.5 to 90 k
z
Between C01 (female) (29) and ground
Resistance
Min. 1 M
z
4
Ground fault in wiring harness
(contact with ground circuit)
a
If no failure is found by check on cause 2, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors C01 and P22, and connect T-adapters to either
female side.
Between C01 (female) (29) and ground, or
between P22 (female) (2) and ground
Resistance
Min. 1 M
z
5 Defective pump controller
If no failure is found by above checks, pump controller is defective. (Since this
is an internal defect, troubleshooting cannot be performed.)
Summary of Contents for PC200-8M0
Page 2: ......
Page 15: ...SEN06111 03 PC200 200LC 220 220LC 8M0 00 100 13 100 Index Table of contents...
Page 87: ...SEN06117 00 PC200 200LC 220 220LC 8M0 10 200 3 200 Power train Power train...
Page 102: ...SEN06118 00 10 300 4 PC200 200LC 220 220LC 8M0 300 Undercarriage and frame Idler Idler 1...
Page 109: ...SEN06118 00 PC200 200LC 220 220LC 8M0 10 300 11 300 Undercarriage and frame Track shoe...
Page 141: ...SEN06119 00 PC200 200LC 220 220LC 8M0 10 401 29 401 Hydraulic system Part 1 Pilot oil filter...
Page 146: ...SEN06120 00 10 402 4 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 148: ...SEN06120 00 10 402 6 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 150: ...SEN06120 00 10 402 8 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 152: ...SEN06120 00 10 402 10 PC200 200LC 220 220LC 8M0 402 Hydraulic system Part 2 Control valve...
Page 201: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 3 403 Hydraulic system Part 3 Swing motor...
Page 204: ...SEN06121 00 10 403 6 PC200 200LC 220 220LC 8M0 403 Hydraulic system Part 3 Swing motor...
Page 211: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 13 403 Hydraulic system Part 3 Travel motor...
Page 221: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 23 403 Hydraulic system Part 3 PPC valve...
Page 237: ...SEN06121 00 PC200 200LC 220 220LC 8M0 10 403 39 403 Hydraulic system Part 3 PPC valve...
Page 271: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 5 600 Electrical system Engine control...
Page 305: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 39 600 Electrical system Machine monitor system...
Page 325: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 59 600 Electrical system Sensor...
Page 329: ...SEN06123 00 PC200 200LC 220 220LC 8M0 10 600 63 600 Electrical system KOMTRAX system...
Page 623: ...SEN06134 00 PC200 200LC 220 220LC 8M0 40 302 3 302 Troubleshooting by failure code Part 2...
Page 679: ...SEN06135 00 PC200 200LC 220 220LC 8M0 40 303 3 303 Troubleshooting by failure code Part 3...
Page 727: ...SEN06136 00 PC200 200LC 220 220LC 8M0 40 304 3 304 Troubleshooting by failure code Part 4...
Page 775: ...SEN06137 00 PC200 200LC 220 220LC 8M0 40 305 3 305 Troubleshooting by failure code Part 5...
Page 825: ...SEN06138 00 PC200 200LC 220 220LC 8M0 40 400 3 400 Troubleshooting of electrical system E mode...
Page 1177: ...SEN06151 00 PC200 200LC 220 220LC 8M0 80 100 19 100 Air conditioner Sensor...