5 Installation
33
5.5.8 Connection to remote mount design
Note
Use ferrules.
• 0.75 mm2 ferrules (AWG 19) for shielding (1S, 2S).
• 0.5 mm2 ferrules (AWG 20) for all other wires.
The shields must not touch one another (this will short out the
signal).
Sensor side
Figure 40: Signal cable 00645914; dimensions in mm (in.)
Item
Terminal
Function / Comment
Color
1
3
Measurement
potential
Green
2
E1
Signal
lead
Violet
3
1S
Shield
for
E1
–
4
E2
Signal
lead
Blue
5
2S
Shield
for
E2
–
6
M2
Solenoid
Red
7
M1
Solenoid
Brown
8
–
Not
assigned
Yellow
– Not
assigned
Orange
9
SE
/
Shield
–
Transmitter side
Figure 41: Signal cable 00645914; dimensions in mm (in.)
Item
Terminal
Function / Comment
Color
1
3
Measurement
potential
Green
2
E1
Signal
lead
Violet
3
1S
Shield
for
E1
–
4
E2
Signal
lead
Blue
5
2S
Shield
for
E2
–
6
M2
Solenoid
Red
7
M1
Solenoid
Brown
8
–
Not
assigned
Yellow
– Not
assigned
Orange
9
SE
/
Shield
–
Change from two to one column
Summary of Contents for 406060
Page 2: ......
Page 98: ...13 Appendix 98 13 3 Declarations of conformity 13 3 1 JUMO flowTRANS MAG S10...
Page 99: ...13 Appendix 99...
Page 100: ...13 Appendix 100...
Page 101: ...13 Appendix 101...
Page 102: ...13 Appendix 102...
Page 103: ...13 Appendix 103...
Page 104: ...13 Appendix 104 13 3 2 JUMO flowTRANS MAG H10...
Page 105: ...13 Appendix 105...
Page 106: ...13 Appendix 106...
Page 107: ...13 Appendix 107...
Page 108: ...13 Appendix 108...
Page 109: ...13 Appendix 109...
Page 110: ...13 Appendix 110 13 3 3 JUMO flowTRANS MAG 10...
Page 111: ...13 Appendix 111...
Page 112: ...13 Appendix 112...
Page 113: ...13 Appendix 113...
Page 115: ......