7 Operation
58
Menu / Parameters
Description
Device Setup / ...Sensor / ...Operating Mode
Flow Direction
Used to set the measuring direction for the sensor.
The device measures and totalizes in both flow directions by default when the device is supplied.
• Forward & Reverse: Used to have the device measure in both flow directions.
• Forward only: Used to have the device measure only in upstream direction.
• Reverse only: Used to have the device measure only in downstream direction.
Default setting: Forward & Reverse
Flow Indication
Used to invert the indicated flow direction.
Default setting: Normal
Device Setup / ...Transmitter
...Units
Used to select the “...Units” submenu with
.
Damping
Used to set the damping.
The value set here (0.02 to 60 s) relates to 1
τ
(Tau). The value refers to the response time to a sudden mass flow rate step
change.
Default setting: 1 second.
Damping On/Off
Used to activate the damping.
Density Fixed Value
If the flow is measured and displayed in units of mass, a fixed density value has to be included in the calculations.
A density value from 0.01 to 5.0 g/cm³ can be set to make the conversion to the mass flow rate.
...Cut Off
Used to select the “...Cut Off” submenu with
.
TX Location TAG
Used to enter the meter location for the transformer.
Alphanumeric, max. 20 characters
TX TAG
Used to enter the TAG number for the transmitter.
Alphanumeric, max. 20 characters
Device Reset
Used to restart the device. Takes the place of a brief interruption of the power supply.
Restore Settings
Used to reset all parameter settings accessible to users to the factory default settings.
...Feature Settings
Used to select the “
...Feature Settings
” submenu with
.
...System Zero
Used to select the “...System Zero” submenu with
.
Noise Reduction
Used to activate noise reduction.
Filter: Off, filter 15, 30, 60 (15: low filtering action; 60: high filtering action)
This setting influences the current output (damping).
Default setting: Off
Summary of Contents for 406060
Page 2: ......
Page 98: ...13 Appendix 98 13 3 Declarations of conformity 13 3 1 JUMO flowTRANS MAG S10...
Page 99: ...13 Appendix 99...
Page 100: ...13 Appendix 100...
Page 101: ...13 Appendix 101...
Page 102: ...13 Appendix 102...
Page 103: ...13 Appendix 103...
Page 104: ...13 Appendix 104 13 3 2 JUMO flowTRANS MAG H10...
Page 105: ...13 Appendix 105...
Page 106: ...13 Appendix 106...
Page 107: ...13 Appendix 107...
Page 108: ...13 Appendix 108...
Page 109: ...13 Appendix 109...
Page 110: ...13 Appendix 110 13 3 3 JUMO flowTRANS MAG 10...
Page 111: ...13 Appendix 111...
Page 112: ...13 Appendix 112...
Page 113: ...13 Appendix 113...
Page 115: ......