5 Installation
22
5.3
Opening and closing the terminal box
WARNING
Risk of injury due to live parts!
When the housing is open, contact protection is not provided
and EMC protection is limited.
• Before opening the housing, switch off the power supply.
Note
Potentially adverse effects on the IP protection class.
• Ensure that the cover for the power supply terminals is
correctly fitted.
• Check the o-ring gasket for damage and replace it as needed,
prior to closing the housing cover.
• Check that the o-ring gasket is correctly seated when closing
the housing cover.
Figure 23: Cover safety catch (example)
Turn the screw
1
clockwise to open the cover and to release the
safety catch.
After closing the cover to the housing, secure the cover by turning
the screw
1
counterclockwise.
5.3.1 Rotating the LCD display
Depending on the installation position, the LCD display can be
rotated to enable horizontal readings.
The LCD display can be rotated in 90° increments in four steps.
Refer to
Opening and closing the terminal box
on page 22!
Rotating the LCD display: Carry out steps
A
to
G
.
Figure 24: Rotating the LCD display (example)
Summary of Contents for 406060
Page 2: ......
Page 98: ...13 Appendix 98 13 3 Declarations of conformity 13 3 1 JUMO flowTRANS MAG S10...
Page 99: ...13 Appendix 99...
Page 100: ...13 Appendix 100...
Page 101: ...13 Appendix 101...
Page 102: ...13 Appendix 102...
Page 103: ...13 Appendix 103...
Page 104: ...13 Appendix 104 13 3 2 JUMO flowTRANS MAG H10...
Page 105: ...13 Appendix 105...
Page 106: ...13 Appendix 106...
Page 107: ...13 Appendix 107...
Page 108: ...13 Appendix 108...
Page 109: ...13 Appendix 109...
Page 110: ...13 Appendix 110 13 3 3 JUMO flowTRANS MAG 10...
Page 111: ...13 Appendix 111...
Page 112: ...13 Appendix 112...
Page 113: ...13 Appendix 113...
Page 115: ......