background image

Bante is committed to the reduction and eventual elimination of all hazardous 
substances

 

in both

 

the

 

manufacturing

 

process

 

and

 

finished

 

products

 

we

 

supply.

We 

 

have an active manufacturing and procurement program to minimize and 

eliminate the

 

use

 

of

 

harmful

 

heavy

 

metals

 

such as cadmium,

 

lead,

 

mercury and 

the like. 
New technologies

 

and

 

design

 

parameters

 

are

 

also

 

promoting these

 

efforts

 

and

 

we

 

expect

 

to

 

have

 

little

 

or

 

no

 

such

 

materials

 

in

 

our

 

product

 

in

 

the

 

coming

 

years. 

We welcome our customers suggestions on how to speed up these efforts.

Hazardous Substance Statement

 

 

 

 

 

 

Warranty

The 

 

warranty 

 

period 

 

for 

 

PHscan 

 

series 

 

tester 

 

is 12 months from the date of

shipment.

 

Above

 

warranty

 

does

 

not

 

cover

 

pH

 

electrode

 

module

 

and

 

calibration

 

solutions.

 

For more information,

 

please contact nearest authorized distributor.

BANTE INSTRUMENTS LIMITED
E-mail: [email protected]
Phone: 0086-21-6404-1598
Website: www.bante-china.com

The information in this document is subject to change without notice.
Copyright © Bante Instruments Limited, 2013. All rights reserved.

PHscan20 Pocket pH Tester

Instruction Manual

Technology to create the future...

BANTE INSTRUMENTS LIMITED

Summary of Contents for PHscan20

Page 1: ...come our customers suggestions on how to speed up these efforts Hazardous Substance Statement Warranty The warranty period for PHscan series tester is 12 months from the date of shipment Above warrant...

Page 2: ...ER HOLD DESCRIPTION Indicates tester is in the measurement mode Indicates tester is in the calibration mode Indicates tester is in SETUP mode Indicates the measured value has been frozen Indicates tem...

Page 3: ...or 8 minutes the tester will automatically turn off to conserve energy To disable the auto off function please read the SETUP MENU section The tester contains an integrated system menu that allows you...

Page 4: ...ress ENTER key to confirm the tester shows YES OFF auto off function is enabled points calibration indicating that indicating that the Enter Cal When the auto off function is enabled 8 Press CAL key t...

Page 5: ...e selected 1 point calibration in the system menu 2 Rinse the pH electrode with distilled water press MEAS key to turn on the tester 3 ait for the measured value to stabilize the display shows END Sin...

Page 6: ...the measured reading you can continue to take measurement Electrode Care and Maintenance For best results please always keep the sensor s glass bulb wet Ensure that the sensor is thoroughly washed wi...

Page 7: ...eparation is done ORDER CODE ITEM E PHSCAN ST Standard pH Electrode Used for routine pH measurements e g drinking water rainwater etc E PHSCAN FT Flat Surface pH Electrode Used for measuring the skin...

Reviews: