5 Installation
29
Procedure
1
Pouch
2
Clamp
3
Two-component sealing
compound
4
Desiccant packet
5
Maximum fill level
Figure 35: Procedure
1. Cut open the protective enclosure of the two-component
sealing compound (see packaging).
2. Remove the clamp of the sealing compound.
3. Knead both components thoroughly until a good mix is
reached.
4. Cut open the pouch at a corner. Perform work activity within
30 minutes.
5. Carefully fill the terminal box with two-component sealing
compound to above the connecting cable.
6. Wait a few hours before closing the cover to allow the
compound to dry, and to release any possible gas.
7. Ensure that the packaging material and the desiccant packet
are disposed of in an environmentally sound manner.