Goodrive350-19 series VFD for crane
Function parameter list
-232-
Function
code
Name
Description
Default
Modify
P04.31
Max. output
voltage
The function codes are used to set the upper
and lower limits of output voltage.
Vmax
Vmin
V set
Time t
t1
t2
t1=P04.29
t2=P04.30
–100.0% (of the
motor rated voltage)
setting range: 0.00Hz
100.0%
◎
P04.32
Output min.
voltage
0.0%
◎
P04.33
Weakening
coefficient in
constant power
zone
1.00
–1.30
1.00
○
P04.34
Pull-in current 1 in
SM V/F control
When the SM VF control mode is enabled, the
function code is used to set the reactive current
of the motor when the output frequency is lower
than the frequency specified by
Setting range: -100.0%
–+100.0% (of the motor
rated current)
20.0%
○
P04.35
Pull-in current 2 in
SM V/F control
When the SM VF control mode is enabled, the
function code is used to set the reactive current
of the motor when the output frequency is lower
than the frequency specified by
Setting range: -100.0%
–+100.0% (of the motor
rated current)
10.0%
○
P04.36
Frequency
threshold for
pull-in current
switching in SM
V/F control
When the SM VF control mode is enabled, the
function code is used to set the frequency
threshold for the switching between pull-in
current 1 and pull-in current 2.
Setting range: 0.00Hz
(Max. output
frequency)
50.00Hz
○
P04.37
Reactive current
closed-loop
proportional
coefficient in SM
When the SM VF control mode is enabled, the
function code is used to set the proportional
coefficient of reactive current closed-loop
control.
50
○