Goodrive350-19 series VFD for crane
Basic operation guidelines
-161-
Function
code
Name
Description
Default
depended
P02.07
Rotor resistance of AM 1 0.001
–65.535Ω
Model
depended
P02.08
Leakage inductance of
AM 1
0.1
–6553.5mH
Model
depended
P02.09
Mutual inductance of AM
1
0.1
–6553.5mH
Model
depended
P02.10
No-load current of AM 1 0.1
–6553.5A
Model
depended
P02.15
Rated power of SM 1 0.1
–3000.0kW
Model
depended
P02.16 Rated frequency of SM 1 0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
P02.17
Number of pole pairs of
SM 1
1
–50
2
P02.18
Rated voltage of SM 1 0
–1200V
Model
depended
P02.19
Rated current of SM 1 0.8
–6000.0A
Model
depended
P02.20
Stator resistance of SM
1
0.001
–65.535Ω
Model
depended
P02.21
Direct-axis inductance of
SM 1
0.01
–655.35mH
Model
depended
P02.22
Quadrature-axis
inductance of SM 1
0.01
–655.35mH
Model
depended
P02.23
Counter-emf constant of
SM 1
0
–10000
300
P05.01
–P
05.06
Function selection of
multifunction digital input
terminals (S1
–S4, HDIA,
HDIB)
35: Switch from motor 1 to motor 2
P08.31
Switching between
motor 1 and motor 2
0x00
–0x14
Ones place: Switchover channel
0: Terminal
1: Modbus communication
2: PROFIBUS/CANopen/DeviceNet
communication
3: Ethernet communication
0x 00