Goodrive350-19 series VFD for crane
Function parameter list
-260-
Function
code
Name
Description
Default
Modify
Tens place: indicates whether to enable
switchover during running
0: Disable
1: Enable
P08.32
FDT1 electrical
level detection
value
When the output frequency exceeds the
corresponding frequency of FDT electrical level,
the multifunction digital output terminal
continuously outputs the signal of "Frequency
level detection FDT". The signal is invalid only
when the output frequency decreases to a value
lower than the frequency corresponding to (FDT
electrical level
—FDT lagging detection value).
Time t
Output frequency f
FDT level
FDT lag
Y1,
RO1, RO2
Time t
setting range: 0.00Hz
(Max.
output frequency)
setting range: 0.0
–100.0% (FDT1
electrical level)
setting range: 0.00Hz
(Max.
output frequency)
setting range: 0.0
–100.0% (FDT2
electrical level)
50.00Hz
○
P08.33
FDT1 lagging
detection value
5.0%
○
P08.34
FDT2 electrical
level detection
value
50.00Hz
○
P08.35
FDT2 lagging
detection value
5.0%
○
P08.36
Detection value
for frequency
being reached
When the output frequency is within the
detection range, the multifunction digital output
terminal outputs the signal of "Frequency
reached".
0.00Hz
○