Goodrive350-19 series VFD for crane
Function parameter list
-336-
Function
code
Name
Description
Default
Modify
0
Fault
Not open the
brake
Time
Output
current %
P90.33
Time
Start/stop
command
Brake
action
Brake
exception
status
Fault
Enabling brake
status monitoring
Brake
feedback
exception
Frequency
reference
P90.32
Brake
feedback
signal
setting range: 0.00
–20.000s
setting range: 0.0%
–200.0% (100.0%
corresponding to the motor rated current)
setting range: 0
–1
0: Disable (Report the brake feedback fault FAE
directly)
1: Enable brake status error speed giving
(Report the brake feedback alarm A-FA
simultaneously)
setting range: 0.00
–50.00Hz
P90.36 Jog braking type
0x00
–0x11
Ones place: Brake release type
0: Same as hoisting-oriented brake release
frequency
1: Same as jog frequency
Tens place: Brake closing type
0: Same as hoisting-oriented brake closing
frequency
1: Same as jog frequency
Same as hoisting-oriented brake release
frequency:
0x00
◎