Goodrive350-19 series VFD for crane
Commissioning guidelines
-106-
Commissioning procedure
1. Set P90.00=6 (User-defined macro 1) for VFD 2, set the parameters for lifting motor 2 according
to the following table of user-defined application macro parameter settings, and note that
A81.24=2 (Slave mode).
2. Set P90.01=7 (User-defined macro 2) for VFD 2, set the parameters for trolley motor according
to the following table of user-defined application macro parameter settings, and note that
A82.24=0 (Disable master/slave mode).
3. When the S1 terminal of VFD 2 is invalid, VFD 2 drives lifting motor 2 and VFD 1 drives lifting
motor 1 to complete the lifting work. When the S2 terminal of VFD 2 is valid, VFD 2 drives the
trolley motor to work.
Motor run
status
VFD 1
VFD 2
KM1
KM2
VFD 2
Terminal
S1
Lifting
motor 1
Lifting
motor
2
Trolley
motor
Lifting run
Master
P28.00=1
Slave
A81.24=2
P28.00=2
Closed Opened
Invalid
Run
Run
Stop
Trolley run
Master/
slave
control is
invalid.
P28.00=0
Modified
through the
PLC
Master/
slave
control is
invalid.
A82.24=0
(P28.00=0)
Swithed
over
through
S1
Opened Closed
Valid
Stop
Stop
Run
Switched
over
through
S1