Goodrive350-19 series VFD for crane
Function parameter list
-331-
Function
code
Name
Description
Default
Modify
with the command.)
1: Enable
(The reverse-running start direction is always
the forward-running direction.)
Tens place: indicates whether to enable forward
torque for reverse-running stop
0: Disable
(The reverse-running stop direction complies
with the command.)
1: Enable
(The reverse-running stop direction is always
the forward-running direction.)
When reverse startup or forward torque for stop
is enabled, the VFD first runs in forward
direction and then runs in reverse direction, so
as to ensure enough torque to drive the load.
P90.06
Graded multi-step
speed reference 0
Graded reference is a speed reference method
for hoisting applications. Graded reference
supports the graded operating lever mode and
graded remote-control mode. Graded reference
can implement 6-step speeds by combing the
five graded multi-step reference terminals. The
combination methods are as follows:
Graded reference terminal
0.0%
○
P90.07
Graded multi-step
speed reference 1
0.0%
○
P90.08
Graded multi-step
speed reference 2
0.0%
○
P90.09
Graded multi-step
speed reference 3
0.0%
○
Run
cmd
REV
Output
frequency
REV
Disable for REV stop
Stop
Stop
Enable for REV stop
Run
cmd
Output
frequency
Run
cmd
REV
Run
cmd
REV
Output
frequency
Disable for REV start
Enable
Output
frequency